文献速递骨肌胸部CT

预测胸腰椎骨质疏松性骨折:基于胸部CT的机器学习价值评估

Predicting Thoracolumbar Vertebral Osteoporotic Fractures: Value Assessment of Chest CT-Based Machine Learning.
PubMed 文献 · Acad Radiol · 2025-07-10

本研究监测8910例接受胸部CT的50岁以上患者(2021—2024年),识别54例新发骨质疏松性椎体骨折,经倾向性评分匹配选取108例对照,共162例随机分为训练组113例和测试组49例。从T11-L2椎体提取放射组学特征构建Radscore模型,并结合临床特征建立列线图模型;列线图模型(Radscore+vBMD+HGB)在训练组和测试组的AUC分别为0.938和0.906,优于Radscore模型(0.902和0.871)和临床模型(0.802和0.820)。

要点

  • 列线图模型(Radscore+vBMD+HGB)预测胸腰椎骨质疏松性骨折的AUC在训练组为0.938、测试组为0.906。
  • 体积骨密度(OR=0.95,95%CI=0.93-0.97)和血红蛋白(OR=0.96,95%CI=0.94-0.98)为独立危险因素。
  • 从2288个放射组学特征中筛选10个计算Radscore,其AUC训练组0.902、测试组0.871。

核心结论

  • 结合放射组学与临床特征的列线图模型对胸腰椎骨质疏松性骨折具有较高的预测性能,其预测结果可为临床决策提供参考。

研究设计与样本

  • 监测8910例年龄≥50岁、2021—2024年接受胸部CT的患者,识别54例新发骨质疏松性椎体骨折,经倾向性评分匹配选取108例对照,共162例随机分为训练组(n=113)和测试组(n=49)。

诊断标准与关键数值

  • 列线图模型(Radscore+体积骨密度+血红蛋白)AUC在训练组为0.938、测试组为0.906;Radscore模型AUC训练组0.902、测试组0.871;临床模型AUC训练组0.802、测试组0.820。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To assess the value of a chest CT-based machine learning model in predicting osteoporotic vertebral fractures (OVFs) of the thoracolumbar vertebral bodies.

MATERIALS AND METHODS: We monitored 8910 patients aged ≥50 who underwent chest CT (2021-2024), identifying 54 incident OVFs cases. Using propensity score matching, 108 controls were selected. The 162 patients were randomly assigned to training (n=113) and testing (n=49) cohorts. Clinical models were developed through logistic regression. Radiomics features were extracted from the thoracolumbar vertebral bodies (T11-L2), with top 10 features selected via minimum-redundancy maximum-relevancy and the least absolute shrinkage and selection operator to construct a Radscore model. Nomogram model was established combining clinical and radiomics features, evaluated using receiver operating characteristic curves, decision curve analysis (DCA) and calibration plots.

RESULTS: Volumetric bone mineral density (vBMD) (OR=0.95, 95%CI=0.93-0.97) and hemoglobin (HGB) (OR=0.96, 95%CI=0.94-0.98) were selected as independent risk factors for clinical model. From 2288 radiomics features, 10 were selected for Radscore calculation. The Nomogram model (Radscore + vBMD + HGB) achieved area under the curve (AUC) of 0.938/0.906 in training/testing cohorts, outperforming both Radscore (AUC=0.902/0.871) and clinical (AUC=0.802/0.820) models. DCA and calibration plots confirmed the Nomogram model's superior prediction capability.

CONCLUSION: Nomogram model combined with radiomics and clinical features has high predictive performance, and its predictive results for thoracolumbar OVFs can provide reference for clinical decision making.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Chen Y, Che M, Yang H, et al. Predicting Thoracolumbar Vertebral Osteoporotic Fractures: Value Assessment of Chest CT-Based Machine Learning. Acad Radiol. 2025. PMID: 40645889. doi:10.1016/j.acra.2025.06.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。