文献速递神经头颈外周血管CT

光子计数探测器CT显示豆纹动脉:与能量积分探测器CT比较及重建模式优化

Photon-Counting Detector CT for Lenticulostriate Arteries: Comparison with Energy-Integrating Detector CT and Reconstruction Mode Optimization.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-01-05

回顾性比较头颈部CTA中光子计数探测器CT(PCD-CT)4种重建模式与能量积分探测器CT(EID-CT)对豆纹动脉(LSA)的显示效果。PCD-CT组56例、EID-CT组28例;PCD-CT的0.2 mm层厚阈值3D模式显示LSA数量最多、长度最长,0.4 mm层厚血管能谱后处理模式主观评分更高;PCD-CT整体优于EID-CT。

要点

  • PCD-CT的0.2 mm层厚阈值3D模式显示LSA数量最多(双侧均为4.00,范围3.00-4.00)。
  • 0.2 mm层厚阈值3D模式测量LSA长度最长(右侧23.33±4.86 mm,左侧24.18±4.51 mm)。
  • 0.4 mm层厚血管能谱后处理模式获得更高的主观评价评分。

核心结论

  • PCD-CT对LSA的显示和图像质量优于EID-CT,作者认为其是未来观察LSA的重要方法。

研究设计与样本

  • 回顾性研究,PCD-CT组56例(平均年龄65±14岁,男28例),EID-CT组28例(平均年龄64±12岁,男14例);PCD-CT图像重建4种模式,EID-CT重建1种模式;采用主观评价和定量评估,Friedman检验比较4种重建模式。

关键影像表现/征象

  • PCD-CT的0.2 mm层厚阈值3D模式显示LSA数量最多:右侧4.00(范围3.00-4.00),左侧4.00(范围3.00-4.00)。
  • PCD-CT的0.2 mm层厚阈值3D模式测量LSA长度最长:右侧23.33±4.86 mm,左侧24.18±4.51 mm。

诊断标准与关键数值

  • PCD-CT的0.4 mm层厚血管能谱后处理模式获得更高的主观评价评分。
  • PCD-CT组较EID-CT组显示LSA数量更多、LSA长度更长、图像质量更优。

临床应用与阅片要点

  • 作者认为PCD-CT是未来观察LSA的重要方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Lenticulostriate arteries (LSAs) are micro but clinically critical perforating vessels that remain difficult to visualize using conventional techniques. This study aimed to conduct a preliminary comparison of the visualization of LSAs in head and neck CTA with photon-counting detector CT (PCD-CT) with 4 reconstruction modes.

MATERIALS AND METHODS: This retrospective study included patients who underwent head and neck CTA with PCD-CT between January 2024 and May 2024 and those who underwent CTA with energy-integrating detector CT (EID-CT) between September 2023 and May 2024. The images were reconstructed in 4 modes for the PCD-CT group and 1 mode for the EID-CT group. The image quality was evaluated, and the LSAs were visualized by using subjective evaluations and quantitative assessments. The Friedman test was used to compare the characteristics of the 4 reconstruction modes.

RESULTS: The PCD-CT group comprised 56 patients (average age 65 ± 14 years; 28 men), and the EID-CT group comprised 28 patients (average age, 64 ± 12 years; 14 men). In the PCD-CT group, the 0.2-mm slice-thickness threshold 3D mode displayed the highest counts of LSAs (right side: 4.00 [range, 3.00-4.00]; left side: 4.00 [range, 3.00-4.00]) and the longest LSAs (right side: 23.33 ± 4.86 mm; left side: 24.18 ± 4.51 mm). The 0.4-mm slice-thickness vascular spectral postprocessing mode obtained higher subjective evaluation scores. Furthermore, the PCD-CT group exhibited a higher count of LSAs, longer LSA lengths, and superior image quality than the EID-CT group.

CONCLUSIONS: PCD-CT achieves better visualization of LSAs and image quality than EID-CT and therefore constitutes an important method for observing LSAs in the future.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Tang W, Li W, Zhao Y, et al. Photon-Counting Detector CT for Lenticulostriate Arteries: Comparison with Energy-Integrating Detector CT and Reconstruction Mode Optimization. AJNR Am J Neuroradiol. 2026. PMID: 40639975. doi:10.3174/ajnr.A8917

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。