基于深度学习在侧位头颈部X线片上行腺样体大小全自动测量的可行性研究
本研究为回顾性研究,纳入两家中心2023年2月至7月采集的711张侧位头颈部X线片,开发并验证基于深度学习(DL)的腺样体大小全自动测量系统,采用Fujioka法,使用RTMDet和RTMPose网络进行关键点检测。结果显示,该系统预测腺样体、鼻咽及腺样体-鼻咽比值的测量值与参考标准一致性高,腺样体测量的ICC为0.902(95%CI 0.872-0.925),鼻咽测量ICC为0.868(95%CI 0.828-0.899),腺样体-鼻咽比值ICC为0.911(95%CI 0.883-0.932)。
要点
- DL系统可全自动测量侧位头颈部X线片上的腺样体、鼻咽及腺样体-鼻咽比值,与参考标准一致性高。
- 腺样体-鼻咽比值测量的ICC为0.911(95%CI 0.883-0.932),MAD为0.054,RMS为0.076。
- 腺样体测量ICC为0.902(95%CI 0.872-0.925),鼻咽测量ICC为0.868(95%CI 0.828-0.899)。
核心结论
- 所开发的DL系统能有效实现侧位头颈部X线片上腺样体-鼻咽比值、腺样体及鼻咽的自动测量,表现出高可靠性。
研究设计与样本
- 回顾性研究,纳入两家中心2023年2月至7月采集的711张侧位头颈部X线片,开发基于Fujioka法的DL腺样体大小测量系统,采用RTMDet网络和RTMPose网络进行关键点检测,并以数学公式计算腺样体大小。
诊断标准与关键数值
- 腺样体测量与参考标准比较:ICC为0.902(95%CI 0.872-0.925),MAD为1.189,RMS为1.974。
- 鼻咽测量与参考标准比较:ICC为0.868(95%CI 0.828-0.899),MAD为1.671,RMS为1.916。
- 腺样体-鼻咽比值测量与参考标准比较:ICC为0.911(95%CI 0.883-0.932),MAD为0.054,RMS为0.076。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The objective and reliable quantification of adenoid size is pivotal for precise clinical diagnosis and the formulation of effective treatment strategies. Conventional manual measurement techniques, however, are often labor-intensive and time-consuming.
OBJECTIVE: To develop and validate a fully automated system for measuring adenoid size using deep learning (DL) on lateral head and neck radiographs.
MATERIALS AND METHODS: In this retrospective study, we analyzed 711 lateral head and neck radiographs collected from two centers between February and July 2023. A DL-based adenoid size measurement system was developed, utilizing Fujioka's method. The system employed the RTMDet network and RTMPose networks for accurate landmark detection, and mathematical formulas were applied to determine adenoid size. To evaluate consistency and reliability of the system, we employed the intra-class correlation coefficient (ICC), mean absolute difference (MAD), and Bland-Altman plots as key assessment metrics.
RESULTS: The DL-based system exhibited high reliability in the prediction of adenoid, nasopharynx, and adenoid-nasopharyngeal ratio measurements, showcasing strong agreement with the reference standard. The results indicated an ICC for adenoid measurements of 0.902 [95%CI, 0.872-0.925], with a MAD of 1.189 and a root mean square (RMS) of 1.974. For nasopharynx measurements, the ICC was 0.868 [95%CI, 0.828-0.899], with a MAD of 1.671 and an RMS of 1.916. Additionally, the adenoid-nasopharyngeal ratio measurements yielded an ICC of 0.911 [95%CI, 0.883-0.932], a MAD of 0.054, and an RMS of 0.076.
CONCLUSIONS: The developed DL-based system effectively automates the measurement of the adenoid-nasopharyngeal ratio, adenoid, and nasopharynx on lateral neck or head radiographs, showcasing high reliability.
引用
- Hao D, Tang L, Li D, et al. Feasibility study of fully automatic measurement of adenoid size on lateral neck and head radiographs using deep learning. Pediatr Radiol. 2025. PMID: 40658209. doi:10.1007/s00247-025-06332-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。