双低扫描方案下椎动脉40 keV虚拟单能图像质量:DLIR与ASIR-V算法的比较

Comparison of image quality of 40 keV virtual monoenergetic images of vertebral arteries using DLIR and ASIR-V algorithms under a dual-low scanning protocol.
PubMed 文献 · Eur J Radiol · 2025-07-03

本研究将88例患者随机分为实验组和对照组,在双低扫描方案下行双能颈动脉CTA,对比DLIR与ASIR-V重建的椎动脉40 keV虚拟单能图像质量。实验组有效辐射剂量较对照组降低44.4%(0.85 mSv对1.53 mSv,P<0.001),DLIR算法尤其是DLIR-H在客观和主观图像质量上均优于ASIR-V 50%,DLIR-H图像质量最佳。

要点

  • 双低扫描方案联合DLIR-H重建可在降低辐射剂量的同时提升椎动脉40 keV虚拟单能图像质量。
  • 实验组有效辐射剂量0.85 mSv较对照组1.53 mSv降低44.4%(P<0.001)。
  • DLIR-H在客观和主观图像质量评估上均优于ASIR-V 50%和DLIR-M(P<0.01)。

核心结论

  • DLIR算法尤其是DLIR-H可显著改善双低扫描方案下椎动脉40 keV虚拟单能图像质量,并在降低辐射暴露的同时提供更优图像质量。

研究设计与样本

  • 随机对照研究,共纳入88例患者,随机分为实验组(n=44)和对照组(n=44),两组均行双能颈动脉CTA,对比剂剂量均为0.5 ml/kg。
  • 实验组噪声指数(NI)为11.0,采用DLIR高强度和中等强度设置(DLIR-H、DLIR-M)及ASIR-V 50%重建;对照组NI为4.0,采用ASIR-V 50%重建。
  • 图像质量采用客观指标(CT值、噪声、信噪比SNR、对比噪声比CNR)和主观指标(图像噪声、血管轮廓、曲面重建CPR、整体图像质量5分制评分)评价。

诊断标准与关键数值

  • 主观评价采用5分制,实验组超过70%的图像评分高于4分,提示图像质量优秀。
  • DLIR-H在客观和主观图像质量评估上均优于ASIR-V 50%和DLIR-M(P<0.01)。

临床应用与阅片要点

  • 作者认为DLIR-H在双低扫描方案下可提供更优的椎动脉40 keV虚拟单能图像质量并减少辐射暴露,可能成为后循环缺血性卒中患者临床应用的有前景选择。
  • 作者指出这些发现提示DLIR-H可在减少辐射暴露相关风险的同时提高诊断准确性,尤其适用于脆弱患者人群。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aims to compare the image quality of 40 keV Virtual Monoenergetic Images (VMI) of the vertebral artery (VA) reconstructed using two algorithms, Deep Learning Image Reconstruction (DLIR) and Adaptive Statistical Iterative Reconstruction (ASIR-V), under a dual-low scanning protocol, which simultaneously reduces both the radiation dose and the contrast agent dose during the CT scanning process.

METHODS: A total of 88 patients were randomly assigned to an experimental group (n = 44) and a control group (n = 44). Both groups underwent dual-energy carotid CT angiography (DE-CTA) with a contrast agent dose of 0.5 ml/kg. The experimental group [Noise Index (NI) = 11.0] used DLIR at high-strength (DLIR-H) and medium-strength setting (DLIR-M), along with Adaptive Statistical Iterative Reconstruction algorithm set at 50 % strength (ASIR-V 50 %), while the control group (NI = 4.0) used ASIR-V 50 %. Image quality was evaluated both objectively [using CT values, noise, Signal-to-Noise Ratio (SNR), and Contrast-to-Noise Ratio (CNR)] and subjectively [using a 5-point scale for image noise, vascular contours, curve planar reformation (CPR), and overall image quality].

RESULTS: The experimental group demonstrated a 44.4 % reduction in effective radiation dose compared to the control group (0.85 mSv and 1.53 mSv, respectively, P < 0.001). DLIR algorithms, especially DLIR-H, significantly reduced image noise and improved both SNR and CNR compared to ASIR-V 50 % (P < 0.01). Subjective evaluation revealed that more than 70 % of the images in the experimental group scored above 4 points, indicating excellent image quality. Furthermore, DLIR-H outperformed both ASIR-V 50 % and DLIR-M in both objective and subjective image quality assessments (P < 0.01).

CONCLUSION: The DLIR algorithm, particularly DLIR-H, significantly improves the quality of 40 keV VMI of the vertebral artery under a dual-low scanning protocol. DLIR-H provides superior image quality with reduced radiation exposure, making it a promising option for clinical applications in patients with posterior circulation ischemic stroke. These findings are important for clinical practice as they suggest that DLIR-H can enhance diagnostic accuracy while minimizing risks associated with radiation exposure, particularly in vulnerable patient populations.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Tang Y, Zhang H, Chen L, et al. Comparison of image quality of 40 keV virtual monoenergetic images of vertebral arteries using DLIR and ASIR-V algorithms under a dual-low scanning protocol. Eur J Radiol. 2025. PMID: 40639023. doi:10.1016/j.ejrad.2025.112276

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。