文献速递神经技术与安全CT

双能CT与单能CT评估脑部血细胞比容和血红蛋白的体内对比分析

Dual- energy CT versus single-energy CT for estimation of hematocrit and hemoglobin in the brain: an in vivo analysis.
PubMed 文献 · Neuroradiology · 2025-07-14

研究纳入83例同期行脑部单能CT和双能CT的患者,测量上矢状窦衰减值并与30天内血细胞比容/血红蛋白做线性回归。双能CT在60 keV以上单能图像与血细胞比容/血红蛋白的相关性优于单能CT,95 keV时相关性最高(r=0.656,p<0.001)。碘/水分解图双变量回归相关性 r=0.659,与单能结果相近。

要点

  • 双能CT单能图像在60 keV以上与血细胞比容/血红蛋白的相关性优于单能CT。
  • 95 keV单能图像相关性最高(r=0.656,p<0.001)。
  • 碘/水分解图双变量回归相关性 r=0.659,与单能结果相近。

核心结论

  • 双能CT在60 keV以上所有单能能级与血细胞比容/血红蛋白的相关性均优于单能CT,95 keV时相关性最佳。

研究设计与样本

  • 83例患者同期采集脑部单能CT与双能CT,测量上矢状窦衰减值,参考标准为30天内全血细胞计数测得的血细胞比容/血红蛋白,采用线性回归分析。

关键影像表现/征象

  • 上矢状窦衰减值在单能CT、双能CT单能图像(40至140 keV,5 keV递增)及双能CT水/碘分解图像上测量。

诊断标准与关键数值

  • 血细胞比容与血红蛋白强相关(r=0.964)。
  • 单能CT上矢状窦衰减与血细胞比容/血红蛋白中度相关(r=0.493/0.458)。
  • 双能CT单能图像(40至140 keV)与血细胞比容/血红蛋白的相关性为中度至强相关(Pearson r 范围0.331-0.656)。
  • 95 keV时相关性最高(r=0.656,p<0.001)。
  • 水分解图像相关性中度(r=0.51),水与碘双变量回归相关性增强(r=0.659),与单能结果相近。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Hematocrit (Hct) and hemoglobin (HB) levels in blood are known to be correlated with vascular attenuation values on single-energy computed tomography (SECT). Dual-energy computed tomography (DECT) is likely to have even better correlations than SECT, given its richer information content, but this remains unproven clinically. We compare and contrast DECT and SECT correlations between attenuation in the superior sagittal sinus (SSS) to patient Hct/HB levels, and explore the use of iodine/water decomposition maps for the same purpose.

METHODS: Brain SECT and DECT were acquired contemporaneously in 83 patients and attenuation was measured in the SSS on SECT, monoenergetic DECT images (40 to 140 keV in 5 keV increments) and DECT material decomposition images (water and iodine). Hct/HB values were from complete blood counts (CBC) within 30 days of imaging. Linear regressions were performed to Hct/HB using the measured attenuations as explanatory variables.

RESULTS: Hct and HB were strongly mutually correlated (r = 0.964). Hct/HB were moderately correlated (r = 0.493/0.458) with SSS attenuation on SECT, and moderately to strongly correlated for DECT (Pearson's r ranging 0.331-0.656) over a range of monoenergetic levels (40 to 140 keV). Above 60 keV, DECT monoenergetic images were better correlated to Hct/HB than SECT, with correlation maximized at 95 keV (r = 0.656, p < 0.001). Material decomposition water images had moderate correlation (r = 0.51), improving to strong correlation (r = 0.659) for a two-variable water and iodine regression, similar to the monoenergetic results.

CONCLUSION: DECT has better correlations to Hct/HB than SECT for all monoenergetic energies above 60 keV, with best correlations at 95 keV.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Dagher R, Jacobsen MC, Vasireddy S, et al. Dual- energy CT versus single-energy CT for estimation of hematocrit and hemoglobin in the brain: an in vivo analysis. Neuroradiology. 2025. PMID: 40658143. doi:10.1007/s00234-025-03700-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。