编织型腔内桥接装置或弹簧圈治疗动脉瘤的MRA评估:观察者间与观察者内可靠性研究
本研究纳入60例动脉瘤(30例WEB装置、30例弹簧圈)的MRA影像,由30名不同临床背景的评估者用Montreal三分类系统分级并给出处理建议。观察者间闭塞分级一致性为显著(κG=0.70;95%CI 0.66–0.75),处理决策一致性亦显著(κG=0.68;95%CI 0.60–0.76),观察者内平均一致性接近完美(κG=0.84±0.06)。闭塞分级与处理建议强相关(平均Cramer's V=0.78±0.13),支持该量表用于无创随访方案。
要点
- Montreal量表用于MRA评估WEB或弹簧圈治疗动脉瘤,观察者间闭塞分级一致性显著(κG=0.70)。
- 处理决策的观察者间一致性显著(κG=0.68),观察者内平均一致性接近完美(κG=0.84±0.06)。
- 闭塞分级与处理建议强相关(平均Cramer's V=0.78±0.13),两种治疗方式间处理策略一致。
核心结论
- Montreal量表在MRA评估WEB或弹簧圈治疗动脉瘤时表现出显著可靠性和临床相关性,支持其用于无创随访方案。
研究设计与样本
- 由30名不同临床背景的评估者对60例动脉瘤(30例WEB装置、30例弹簧圈)的电子影像集进行评估,使用Montreal三分类系统分级并给出处理建议;其中23名评估者一个月后完成置换病例的第二次评估;采用Gwet's AC2(κG)系数评估可靠性,Cramer's V分析闭塞分级与处理建议的相关性。
诊断标准与关键数值
- 观察者间闭塞分级一致性κG=0.70(95%CI 0.66–0.75);WEB治疗动脉瘤κG=0.66(95%CI 0.59–0.74),弹簧圈治疗动脉瘤κG=0.75(95%CI 0.68–0.82);处理决策总体一致性κG=0.68(95%CI 0.60–0.76);观察者内平均一致性κG=0.84±0.06;闭塞分级与处理建议平均Cramer's V=0.78±0.13。
临床应用与阅片要点
- 作者认为Montreal量表在MRA评估WEB或弹簧圈治疗动脉瘤时具有显著可靠性和临床相关性,支持其用于无创随访方案。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Magnetic resonance angiography (MRA) is a commonly used non-invasive imaging modality for the follow-up of treated intracranial aneurysms. The 3-category Montreal classification system is widely used to evaluate treatment outcomes, including aneurysms treated with Woven EndoBridge (WEB) devices or coils. This study aimed to assess the reliability and clinical implications of the Montreal scale for aneurysms imaged with MRA.
METHODS: An electronic portfolio of 60 aneurysms (30 treated with WEB devices and 30 with coils) was evaluated by 30 raters from diverse clinical backgrounds. Raters graded aneurysm occlusion using the Montreal classification system and provided management recommendations (delayed follow-up, close follow-up, or re-treatment). Twenty-three raters completed a second evaluation of permuted cases after one month. Reliability was assessed using Gwet's AC2 (κG) coefficients, and the correlation between occlusion grade and management recommendation was analyzed with Cramer's V.
RESULTS: Inter-rater agreement for occlusion grades was substantial (κG = 0.70; 95% CI: 0.66-0.75) and similar for WEB-treated (κG = 0.66; 95% CI: 0.59-0.74) and coiled aneurysms (κG = 0.75; 95% CI: 0.68-0.82). Management decisions showed substantial agreement overall (κG = 0.68; 95% CI: 0.60-0.76). Mean intra-rater agreement was almost perfect (κG = 0.84 ± 0.06). Strong correlations were observed between occlusion grades and management recommendations (mean Cramer's V = 0.78 ± 0.13), with consistent management strategies across treatment modalities.
CONCLUSION: The Montreal scale demonstrated substantial reliability and clinical relevance for evaluating aneurysms treated with WEB or coils using MRA, supporting its use in non-invasive follow-up protocols.
引用
- Comby PO, Darsaut TE, Benomar A, et al. MRA evaluation of aneurysms treated with woven endobridge (WEB) devices or coils: an inter- and intra-observer reliability study. Neuroradiology. 2025. PMID: 40694083. doi:10.1007/s00234-025-03706-x