文献速递神经外周血管CTDSA

人工智能工具检测大血管闭塞:系统综述与荟萃分析

Detection of large vessel occlusion using artificial intelligence tools: A systematic review and meta-analysis.
PubMed 文献 · Neuroradiology · 2025-07-30

该系统综述与荟萃分析纳入9项研究共1270例急性大血管闭塞卒中患者,比较AI辅助与标准影像评估。AI辅助评估使门-腹股沟穿刺时间平均缩短20.55分钟、CTA至再灌注时间缩短14.99分钟,但功能独立(改良Rankin量表0-2分)与死亡率无显著差异。

要点

  • AI辅助CTA评估使门-腹股沟穿刺时间平均缩短20.55分钟(95%CI -36.69至-4.42分钟,p<0.01)。
  • AI辅助评估使CTA至再灌注时间平均缩短14.99分钟(95%CI -28.45至-1.53分钟,p=0.03)。
  • 功能独立(改良Rankin量表0-2分)与死亡率在AI辅助组与标准流程间无显著差异。

核心结论

  • 在急性缺血性卒中大血管闭塞检测中整合AI软件可提升工作流效率并缩短治疗时间,但与传统评估相比未改善临床结局。

研究设计与样本

  • 系统综述与荟萃分析,检索PubMed、Embase和Web of Science,纳入9项比较AI软件辅助与标准影像评估的研究,共1270例患者,其中671例(52.8%)接受AI辅助影像评估;采用随机效应模型合并连续结局的均数差与二分类结局的比值比(OR)及95%CI。

诊断标准与关键数值

  • 功能独立定义为改良Rankin量表0-2分,AI辅助组与标准流程组OR 1.27(95%CI 0.92至1.76,p=0.14),无显著差异。
  • 死亡率AI辅助组与标准流程组OR 0.71(95%CI 0.27至1.88,p=0.49),无显著差异。
  • 门-腹股沟穿刺时间AI辅助评估较标准评估平均缩短20.55分钟(95%CI -36.69至-4.42分钟,p<0.01)。
  • CTA至再灌注时间AI辅助评估较标准评估平均缩短14.99分钟(95%CI -28.45至-1.53分钟,p=0.03)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Large vessel occlusion (LVO) accounts for a third of all ischemic strokes. Artificial intelligence (AI) has shown good accuracy in identifying LVOs on computed tomography angiograms (CTA). We sought to analyze whether AI-adjudicated CTA improves workflow times and clinical outcomes in patients with confirmed LVOs.

MATERIALS AND METHODS: We systematically searched PubMed, Embase, and Web of Science for studies comparing initial radiological assessment assisted by AI softwares versus standard assessment of patients with acute LVO strokes. Results were pooled using a random-effects model as mean differences for continuous outcomes or odds ratio (OR) for dichotomous outcomes, along with 95% confidence intervals (CI).

RESULTS: We included 9 studies comprising 1,270 patients, of whom 671 (52.8%) had AI-assisted radiological assessment. AI consistently improved treatment times when compared to standard assessment, as evidenced by a mean reduction of 20.55 minutes in door-to-groin time (95% CI -36.69 to -4.42 minutes; p<0.01) and a reduction of 14.99 minutes in CTA to reperfusion (95% CI -28.45 to -1.53 minutes; p=0.03). Functional independence, defined as a modified Rankin scale 0-2, occurred at similar rates in the AI-supported group and with the standard workflow (OR 1.27; 95% CI 0.92 to 1.76; p=0.14), as did mortality (OR 0.71; 95% CI 0.27 to 1.88; p=0.49).

CONCLUSIONS: The incorporation of AI softwares for LVO detection in acute ischemic stroke enhanced workflow efficiency and was associated with decreased time to treatment. However, AI did not improve clinical outcomes as compared with standard assessment.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Dantas J, Barros G, Mutarelli A, et al. Detection of large vessel occlusion using artificial intelligence tools: A systematic review and meta-analysis. Neuroradiology. 2025. PMID: 40736601. doi:10.1007/s00234-025-03716-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。