深度学习重建加速脑磁共振成像:儿童神经影像图像质量的对比研究
回顾性纳入116例儿童,比较常规MRI(C-MRI)、常规MRI联合深度学习重建(DLC-MRI)及深度学习重建加速MRI(DLA-MRI)的图像质量。DLA-MRI较C-MRI扫描时间缩短43%,整体图像质量、噪声及伪影评分更高,病灶检出率三种重建均为100%,观察者间一致性为中等至几乎完全一致(加权Cohen kappa=0.72-0.97)。
要点
- DLA-MRI较C-MRI扫描时间缩短43%,可用于减少儿童镇静需求。
- DLA-MRI整体图像质量、噪声及伪影评分高于C-MRI,锐利度相似或更低。
- 三种重建方法病灶检出率均为100%,DLC-MRI各项评分最高。
核心结论
- 深度学习重建实现了更快的MRI扫描,且图像质量较常规MRI改善,可能有助于解决儿童神经影像扫描时间过长的问题并优化临床工作流程。
研究设计与样本
- 回顾性研究,纳入116例儿童(平均年龄7.9±5.4岁),均行常规脑MRI并以三种方法重建:无深度学习重建的常规MRI(C-MRI)、联合深度学习重建的常规MRI(DLC-MRI)及深度学习重建加速MRI(DLA-MRI);由两名儿童放射科医生独立评估图像质量。
关键影像表现/征象
- DLA-MRI整体图像质量、噪声及伪影评分高于C-MRI。
- DLA-MRI病灶显示度评分与C-MRI相似或更高,锐利度评分相似或更低。
- DLC-MRI所有参数评分最高。
- 三种重建方法病灶检出率均为100%。
诊断标准与关键数值
- 两名儿童放射科医生独立评估整体图像质量、锐利度、伪影、噪声及病灶显示度。
- 定量分析测量图像噪声及变异系数(CoV),DLA-MRI噪声及CoV低于C-MRI。
- 观察者间一致性加权Cohen kappa=0.72-0.97,为中等至几乎完全一致。
临床应用与阅片要点
- DLA-MRI可缩短扫描时间43%,图像质量整体不低于C-MRI,病灶检出率与C-MRI相同(100%)。
- DLA-MRI锐利度评分相似或低于C-MRI,阅片时需结合原始图像评估细微结构。
- DLC-MRI各项图像质量评分最高,但未缩短扫描时间。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Magnetic resonance imaging (MRI) is crucial in pediatric radiology; however, the prolonged scan time is a major drawback that often requires sedation. Deep learning reconstruction (DLR) is a promising method for accelerating MRI acquisition.
OBJECTIVE: To evaluate the clinical feasibility of accelerated brain MRI with DLR in pediatric neuroimaging, focusing on image quality compared to conventional MRI.
MATERIALS AND METHODS: In this retrospective study, 116 pediatric participants (mean age 7.9 ± 5.4 years) underwent routine brain MRI with three reconstruction methods: conventional MRI without DLR (C-MRI), conventional MRI with DLR (DLC-MRI), and accelerated MRI with DLR (DLA-MRI). Two pediatric radiologists independently assessed the overall image quality, sharpness, artifacts, noise, and lesion conspicuity. Quantitative image analysis included the measurement of image noise and coefficient of variation (CoV).
RESULTS: DLA-MRI reduced the scan time by 43% compared with C-MRI. Compared with C-MRI, DLA-MRI demonstrated higher scores for overall image quality, noise, and artifacts, as well as similar or higher scores for lesion conspicuity, but similar or lower scores for sharpness. DLC-MRI demonstrated the highest scores for all the parameters. Despite variations in image quality and lesion conspicuity, the lesion detection rates were 100% across all three reconstructions. Quantitative analysis revealed lower noise and CoV for DLA-MRI than those for C-MRI. Interobserver agreement was substantial to almost perfect (weighted Cohen's kappa = 0.72-0.97).
CONCLUSION: DLR enabled faster MRI with improved image quality compared with conventional MRI, highlighting its potential to address prolonged MRI scan times in pediatric neuroimaging and optimize clinical workflows.
引用
- Choi JW, Cho YJ, Lee SB, et al. Accelerated brain magnetic resonance imaging with deep learning reconstruction: a comparative study on image quality in pediatric neuroimaging. Pediatr Radiol. 2025. PMID: 40650736. doi:10.1007/s00247-025-06314-2