文献速递神经MRPET

脑MRI燕尾征在临床不确定帕金森综合征患者中的诊断价值

Diagnostic Value of Swallow Tail Sign at Brain MRI in Patients with Clinically Uncertain Parkinsonian Syndrome.
PubMed 文献 · Radiology · 2025-01-01

这项前瞻性多中心研究纳入106例临床不确定帕金森综合征患者,比较3-T SW MRI燕尾征缺失与123I-FP-CIT SPECT诊断帕金森病的效能,以临床随访诊断为参考标准。燕尾征缺失预测帕金森病的敏感度为81%、特异度为75%,诊断信心高亚组准确度达90%;SPECT敏感度更高(98%)但特异度仅55%。

要点

  • 临床不确定帕金森综合征患者中,3-T SW MRI燕尾征缺失预测帕金森病敏感度81%、特异度75%。
  • 诊断信心高的亚组(60/106例)燕尾征评估准确度达90%,敏感度91%、特异度87%。
  • 123I-FP-CIT SPECT敏感度98%高于燕尾征,但特异度55%较低。

核心结论

  • 在临床不确定帕金森综合征患者中,3-T脑SW MRI燕尾征缺失支持帕金森病诊断,总体准确度高,且当燕尾征评估的诊断信心高时准确度更高。

研究设计与样本

  • 前瞻性多中心研究,2016年5月至2019年5月纳入106例临床不确定帕金森综合征患者,均行诊断性3-T SW MRI;影像专科医师在不知临床资料情况下独立评估SW MRI与123I-FP-CIT SPECT图像,以临床随访诊断为参考标准。

关键影像表现/征象

  • SW MRI上评估燕尾征缺失用于预测帕金森病,评估者内信度κ=0.69(95%CI:0.55,0.83),评估者间信度κ=0.70(95%CI:0.56,0.84),一致性均属中等程度。

诊断标准与关键数值

  • 燕尾征缺失预测帕金森病:敏感度81%(95%CI:70,90),特异度75%(95%CI:58,88)。
  • 诊断信心高亚组(60/106例):敏感度91%(95%CI:79,98;Z=2.8;P=.005),特异度87%(95%CI:60,98;Z=1.4;P=.17),准确度90%(95%CI:79,96;Z=3.1;P=.002)。
  • 123I-FP-CIT SPECT:敏感度98%(95%CI:91,100;Z=3.3;P=.001)高于燕尾征,特异度55%(95%CI:39,70;Z=-1.9;P=.06)。

临床应用与阅片要点

  • 对临床不确定帕金森综合征患者,3-T脑SW MRI燕尾征缺失可作为支持帕金森病诊断的影像征象。
  • 燕尾征评估者内与评估者间一致性均为中等程度(κ=0.69与κ=0.70),阅片时应结合诊断信心判断。
  • 123I-FP-CIT SPECT敏感度98%高于燕尾征的81%,但特异度55%低于燕尾征的75%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Striatal dopaminergic deficits, established with iodine 123-2β-carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl)-nortropan (123I-FP-CIT) SPECT, support the diagnosis of Parkinson disease (PD) or atypical parkinsonian syndrome in clinical uncertainty. The swallow tail sign (STS) at susceptibility-weighted (SW) MRI helps differentiate patients with PD from controls, but its utility in clinically uncertain parkinsonian syndromes remains unclear. Purpose To compare the diagnostic performance of STS absence at SW MRI in diagnosing PD with that of 123I-FP-CIT SPECT in participants with clinically uncertain parkinsonian syndrome. Materials and Methods This prospective, multicenter study included participants with clinically uncertain parkinsonian syndrome between May 2016 and May 2019. Imaging modality specialists independently assessed images from SW MRI and 123I-FP-CIT SPECT while blinded to clinical findings. Diagnostic performance was assessed against diagnosis at clinical follow-up as the reference standard. Performance metrics were compared between modalities and post hoc subgroups split by diagnostic confidence and motor severity using Z tests. Cohen κ was computed for intrarater, interrater, and intermodality reliability. Results A total of 106 participants with clinically uncertain parkinsonian syndrome and diagnostic 3-T SW MRI examinations were included in the study sample (median age, 69 years [IQR, 14 years]; 59 male). STS assessment showed substantial agreement within (κ = 0.69; 95% CI: 0.55, 0.83) and between (κ = 0.70; 95% CI: 0.56, 0.84) raters. STS absence demonstrated a sensitivity of 81% (95% CI: 70, 90) and specificity of 75% (95% CI: 58, 88) in predicting PD. Post hoc analysis demonstrated better diagnostic performance in the subgroup with high (60 of 106 participants) versus low diagnostic confidence, with 91% sensitivity (95% CI: 79, 98; Z = 2.8; P = .005), 87% specificity (95% CI: 60, 98; Z = 1.4; P = .17), and 90% accuracy (95% CI: 79, 96; Z = 3.1; P = .002). 123I-FP-CIT SPECT yielded higher sensitivity than STS (98% [95% CI: 91, 100]; Z = 3.3; P = .001) but only 55% specificity (95% CI: 39, 70; Z = -1.9; P = .06). Conclusion In participants with clinically uncertain parkinsonian syndrome, STS absence on 3-T brain SW MRI scans supported the diagnosis of PD with high accuracy overall and greater accuracy when the diagnostic confidence of STS assessment was high. Clinical trial registration no. NCT03022357 © RSNA, 2025 Supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Xing Y, Naidu S, Martín-Bastida A, et al. Diagnostic Value of Swallow Tail Sign at Brain MRI in Patients with Clinically Uncertain Parkinsonian Syndrome. Radiology. 2025. PMID: 40626875. doi:10.1148/radiol.240680

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。