文献速递神经技术与安全USCT

超声与CT测量视神经鞘直径的非侵入性一致性:系统综述与Meta分析

Ultrasound and CT Agreement for Non-Invasive ONSD Measurement: A Systematic Review and Meta-Analysis.
PubMed 文献 · Ultrasound Med Biol · 2025-07-18

该系统综述与Meta分析纳入8项非随机研究共273例患者,比较超声与CT测量视神经鞘直径(ONSD)的一致性;汇总平均差值为-0.07 mm(95%CI -0.75至0.61,p=0.85),无统计学显著差异;组内相关系数(ICC)为0.80(95%CI 0.26-0.96),Bland-Altman分析一致性界限为-1.52至1.38 mm,提示两种模态总体一致但异质性较高。

要点

  • 超声与CT测量ONSD的汇总平均差值为-0.07 mm(95%CI -0.75至0.61,p=0.85),无统计学显著差异。
  • ICC为0.80(95%CI 0.26-0.96),Bland-Altman一致性界限-1.52至1.38 mm,提示总体一致性尚可。
  • 研究间异质性较高,作者结论认为两种模态在颅内压升高患者中表现可比。

核心结论

  • 在颅内压升高患者中,超声与CT测量ONSD总体一致;尽管异质性较高,两种模态表现似乎可比,超声具有便携和避免辐射的优势,CT可作为急诊中的可靠替代。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、Cochrane Library和Lilacs数据库,纳入同时比较超声与CT测量ONSD的随机和非随机研究。
  • 共纳入8项非随机研究、273例患者,仅纳入报告两种模态平均ONSD测量值的研究。
  • 采用I2统计量评估异质性,应用随机效应模型合成汇总估计,主要结局为超声与CT测量ONSD的平均差值及组内相关系数(ICC)。
  • 因观察到高异质性,进行了亚组和敏感性分析。

诊断标准与关键数值

  • 超声与CT测量ONSD的汇总平均差值为-0.07 mm(95%CI -0.75至0.61,p=0.85),无统计学显著差异。
  • 组内相关系数(ICC)为0.80(95%CI 0.26-0.96),提示两种影像模态间一致性较高。
  • Bland-Altman分析显示一致性界限为-1.52至1.38 mm,大多数数据点落在这些界限内。

临床应用与阅片要点

  • 作者结论认为,超声与CT在颅内压升高患者的ONSD测量中总体一致,超声具有便携和避免辐射的优势,CT可作为急诊中的可靠替代。
  • 原文未据此给出具体的临床推荐或阅片操作建议。

局限性

  • 研究间观察到显著异质性。
  • 纳入的8项研究均为非随机研究。
  • ICC的95%CI较宽(0.26-0.96)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: The measurement of the optic nerve sheath diameter (ONSD) is an established non-invasive technique for diagnosing and monitoring elevated intracranial pressure (ICP) across various imaging modalities. However, the agreement between ONSD measurements obtained using ultrasonography (US) and computed tomography (CT) remains unclear. This systematic review and meta-analysis aimed to evaluate the concordance between these modalities for ONSD measurement in the diagnosis of elevated ICP, exploring whether they yield equivalent results and can be used interchangeably in clinical practice.

METHODS: We systematically searched PubMed, Cochrane Library and Lilacs databases for randomized and non-randomized studies that simultaneously compared US and CT measurements of the ONSD in patients diagnosed with elevated ICP. Only studies reporting mean ONSD measurements for both modalities were included. Heterogeneity among studies was assessed using the I2 statistic, and a random-effects model was applied to synthesize pooled estimates for outcomes. The primary outcome was the mean difference between ONSD measurements obtained by US and CT and the inter-class correlation coefficient (ICC). Due to the high heterogeneity observed, we conducted subgroup and sensitivity analysis.

RESULTS: We included 8 non-randomized studies with 273 patients. The pooled mean difference between US and CT measurements of the ONSD was MD -0.07 mm; 95% confidence interval [CI] -0.75 to 0.61; p = 0.85, indicating no statistically significant difference between the two modalities. Substantial heterogeneity was observed across studies. Bland-Altman analysis demonstrated limits of agreement ranging from -1.52 to 1.38 mm., with most data points falling within these limits. The ICC was 0.80 (95% CI: 0.26-0.96), indicating substantial agreement between the two imaging modalities.

CONCLUSION: In conclusion, US and CT show general agreement in ONSD measurements for patients with elevated ICP. While heterogeneity was high, both modalities appear comparable, with US offering advantages in portability and radiation avoidance, and CT serving as a reliable alternative in emergencies.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Castilho VA, Mendonça JA, Maciel RC, et al. Ultrasound and CT Agreement for Non-Invasive ONSD Measurement: A Systematic Review and Meta-Analysis. Ultrasound Med Biol. 2025. PMID: 40683820. doi:10.1016/j.ultrasmedbio.2025.06.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。