Silk Vista Baby 用于治疗远端大脑前动脉动脉瘤
这项多中心回顾性研究纳入20个中心的79例未破裂远端大脑前动脉动脉瘤患者,均使用Silk Vista Baby血流导向装置治疗。中位随访12个月时,76%动脉瘤达到完全或近完全闭塞,血栓栓塞或出血并发症发生率为14%,死亡率为0%,再治疗率为1.3%。作者认为Silk Vista Baby是治疗远端大脑前动脉动脉瘤的有价值选择。
要点
- Silk Vista Baby血流导向装置适用于载瘤动脉中位直径1.9 mm的远端大脑前动脉动脉瘤。
- 末次随访时76%动脉瘤达到完全或近完全闭塞(O'Kelly-Marotta C或D级,Raymond-Roy 1或2级)。
- 血栓栓塞或出血并发症发生率为14%,其中2例为症状性,死亡率为0%。
核心结论
- 在这项多中心系列中,Silk Vista Baby血流导向装置是治疗远端大脑前动脉动脉瘤的有价值选择。
研究设计与样本
- 回顾性多中心研究,纳入20个中心的79例未破裂远端大脑前动脉动脉瘤患者(79个动脉瘤),治疗时间为2018年1月至2022年12月,使用Silk Vista Baby血流导向装置(兼容0.017″微导管)。
诊断标准与关键数值
- 末次随访时76%动脉瘤达到完全或近完全闭塞,定义为O'Kelly-Marotta量表C或D级、Raymond-Roy分级1或2级。
- 载瘤动脉中位直径为1.9 mm(IQR 1.7-2.1)。
- 97.5%的病例植入单枚支架,2.5%需要两枚支架。
- 中位影像随访时间为12个月(IQR 9.5-24)。
临床应用与阅片要点
- 作者认为Silk Vista Baby血流导向装置是治疗远端大脑前动脉动脉瘤的有价值选择。
- 总体血栓栓塞或出血并发症发生率为14%,其中2例为症状性,死亡率为0%,再治疗率为1.3%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Treating small-caliber vessel aneurysms with flow diverters poses challenges due to narrow luminal diameters and tortuous vasculature, which complicate the navigation and deployment of conventional devices using standard microcatheters. The Silk Vista Baby (SVB, Balt, Montmorency, France) flow diverter was developed to treat intracranial aneurysms located in smaller vessels or more distal segments and is compatible with 0.017″ microcatheters. We present the largest multicenter analysis to date evaluating the outcomes of SVB use in unruptured distal anterior cerebral artery (DACA) aneurysms.
METHODS: Retrospective data from 20 centers were reviewed for patients with unruptured DACA aneurysms treated with the SVB. Demographic information, clinical presentation, radiographic characteristics, complications, and outcomes were recorded.
RESULTS: Seventy-nine patients (79 DACA aneurysms) were treated between January 2018 and December 2022; 59 were female (74.7%), and the median age was 61 years (IQR 53-67). Most aneurysms were saccular (89.9%), and 65.8% involved a branch. The median parent vessel diameter was 1.9 mm (IQR 1.7-2.1). A single stent was implanted in 97.5% of cases; 2.5% required two stents. The median imaging follow-up duration was 12 months (IQR 9.5-24). At the last follow-up, 76% of aneurysms showed complete or near-complete occlusion (O'Kelly-Marotta scale C or D, Raymond-Roy 1 or 2). Overall, thromboembolic or hemorrhagic complications occurred in 14% of patients, with two cases being symptomatic. The mortality rate was 0%, and the retreatment rate was 1.3%.
CONCLUSION: In this multicenter series, the SVB flow diverter represented a valuable treatment option for distal anterior cerebral artery (DACA) aneurysms.
引用
- Scarcia L, Clarençon F, Dmytriw AA, et al. Silk Vista Baby for the treatment of distal anterior cerebral artery aneurysms. Neuroradiology. 2025. PMID: 40601068. doi:10.1007/s00234-025-03678-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。