多机构关于7T MRI用于脑深部电刺激的推荐意见
本文基于超过1000例7T MRI引导脑深部电刺激(DBS)手术经验,总结多机构共识,涵盖7T MRI在DBS术前靶点定位和术后程控中的技术应用。7T MRI较低场强可改善空间分辨率、信噪比和组织对比度,能更清晰显示丘脑底核、苍白球内侧部和丘脑等深部核团及其皮层投射。文章就影像采集、后处理、畸变校正、伪影抑制和特定序列提供最佳实践推荐,以促进7T MRI在DBS中的安全有效应用。
要点
- 7T MRI较低场强可提高空间分辨率、信噪比和组织对比度,改善DBS靶点可视化。
- 推荐关注畸变校正、伪影抑制和特定序列选择以优化深部核团显示。
- 多机构经验支持7T MRI用于DBS术前靶点定位和术后程控。
核心结论
- 多机构共识认为,7T MRI可改善DBS靶点(丘脑底核、苍白球内侧部、丘脑)的可视化,推荐通过畸变校正、伪影抑制和特定序列优化图像质量,以促进其在DBS中的安全有效应用。
研究设计与样本
- 多机构共识/综述,基于超过1000例使用7T MRI引导DBS手术的临床经验,总结影像采集和后处理技术。
关键影像表现/征象
- 7T MRI较低场强提供更优的深部脑核团(丘脑底核、苍白球内侧部、丘脑)及其广泛皮层投射的可视化。
- 7T MRI可提高空间分辨率、信噪比和组织对比度。
- 通过畸变校正、伪影抑制和特定成像序列可优化常见DBS靶点的显示。
临床应用与阅片要点
- 作者推荐在DBS术前靶点定位和术后程控中应用7T MRI,并采用畸变校正、伪影抑制和特定序列优化图像质量。
- 推荐基于患者特异性解剖和连接模型进行个性化手术规划和术后程控。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Deep brain stimulation (DBS) is an established therapeutic intervention for a range of neurological disorders, including Parkinson's disease, essential tremor, and epilepsy. The efficacy of DBS is predicated on the modulation of dysfunctional neural circuits through the application of electrical pulses. Recent advancements in MRI technology have facilitated the visualization of brain nuclei and their associated networks, which is critical for proper patient-specific targeting of electrodes in surgical procedures. This advancement aims to personalize surgical planning and postoperative programming by integrating patient-specific anatomical and connectivity models. The advent of clinical ultrahigh-field MRI, particularly 7T MRI, significantly enhances the targeting of DBS by improving spatial resolution, signal-to-noise ratio, and tissue contrast. Compared with lower field strengths, 7T MRI provides superior visualization of deeply situated brain nuclei and their extensive cortical projections, including the subthalamic nucleus, globus pallidus internus, and thalamus. This review synthesizes a multi-institutional consensus regarding the technical and clinical applications of 7T MRI, drawing on experience from more than 1000 procedures using 7T DBS. It encompasses both imaging acquisition and postprocessing techniques aimed at optimizing image quality. Our extensive clinical experience informs best practices for correcting distortions, mitigating image artifacts, and employing specific imaging sequences that enhance the visualization of common DBS targets. The insights and recommendations presented are intended to promote the safe and effective utilization of 7T MRI in DBS.
引用
- Middlebrooks EH, Bot M, Patriat R, et al. Multi-institutional recommendations on the use of 7T MRI in deep brain stimulation. J Neurosurg. 2025. PMID: 40614283. doi:10.3171/2025.3.JNS243024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。