文献速递腹部技术与安全CTMRUS

影像组学对胃肠道间质瘤风险分层的诊断准确性:系统综述与Meta分析

Diagnostic accuracy of radiomics in risk stratification of gastrointestinal stromal tumors: A systematic review and meta-analysis.
PubMed 文献 · Eur J Radiol · 2025-06-07

该系统综述与Meta分析纳入29项研究(18项可合并),评估影像组学对GIST术前风险分层的诊断准确性。训练队列合并敏感度0.84、特异度0.86、AUC 0.90,验证队列分别为0.84、0.80、0.89。影像组学有潜力作为无创风险分层工具,但仍处于临床应用的早期阶段。

要点

  • 影像组学对GIST风险分层验证队列合并AUC为0.89,敏感度0.84、特异度0.80
  • 纳入研究中76%基于CT,内镜超声、MRI、超声研究较少
  • QUADAS-2提示部分偏倚,主要因阈值未预先设定

关键影像表现/征象

  • 29项研究中22项(76%)基于CT,2项(7%)基于内镜超声,3项(10%)基于MRI,2项(7%)基于超声。
  • 训练队列合并敏感度0.84、特异度0.86、AUC 0.90。
  • 验证队列合并敏感度0.84、特异度0.80、AUC 0.89。

诊断标准与关键数值

  • 训练队列影像组学风险分层合并敏感度0.84、特异度0.86、AUC 0.90。
  • 验证队列影像组学风险分层合并敏感度0.84、特异度0.80、AUC 0.89。
  • QUADAS-2提示部分偏倚,主要因阈值未预先设定。
  • 平均RQS评分为13.14 ± 3.19。

临床应用与阅片要点

  • 影像组学可作为GIST术前无创风险分层的辅助参考,但不能替代活检或手术。
  • CT是当前GIST影像组学研究最主要模态,阅片时关注纹理特征与风险分层的关联。
  • 注意验证队列特异度(0.80)低于训练队列(0.86),提示模型泛化性能有限。

局限性

  • QUADAS-2提示部分偏倚,主要因阈值未预先设定。
  • 平均RQS评分13.14 ± 3.19,影像组学研究质量仍有提升空间。
  • 仅18/29项研究数据可合并,部分模态研究数量少。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: This systematic review and meta-analysis aimed to assess the diagnostic accuracy of radiomics in risk stratification of gastrointestinal stromal tumors (GISTs). It focused on evaluating radiomic models as a non-invasive tool in clinical practice.

MATERIALS AND METHODS: A comprehensive search was conducted across PubMed, Web of Science, EMBASE, Scopus, and Cochrane Library up to May 17, 2025. Studies involving preoperative imaging and radiomics-based risk stratification of GISTs were included. Quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool and Radiomics Quality Score (RQS). Pooled sensitivity, specificity, and area under the curve (AUC) were calculated using bivariate random-effects models. Meta-regression and subgroup analyses were performed to explore heterogeneity.

RESULTS: A total of 29 studies were included, with 22 (76 %) based on computed tomography scans, while 2 (7 %) were based on endoscopic ultrasound, 3 (10 %) on magnetic resonance imaging, and 2 (7 %) on ultrasound. Of these, 18 studies provided sufficient data for meta-analysis. Pooled sensitivity, specificity, and AUC for radiomics-based GIST risk stratification were 0.84, 0.86, and 0.90 for training cohorts, and 0.84, 0.80, and 0.89 for validation cohorts. QUADAS-2 indicated some bias due to insufficient pre-specified thresholds. The mean RQS score was 13.14 ± 3.19.

CONCLUSION: Radiomics holds promise for non-invasive GIST risk stratification, particularly with advanced imaging techniques. However, radiomic models are still in the early stages of clinical adoption. Further research is needed to improve diagnostic accuracy and validate their role alongside conventional methods like biopsy or surgery.

来源:Eur J Radiol,查看原文。版权归原作者所有。