文献速递儿科影像腹部技术与安全US

超声诊断儿童中肠旋转不良和肠扭转的诊断效能:多机构回顾性分析

Diagnostic Performance of Ultrasound for Diagnosing Midgut Malrotation and Volvulus in Children: A Multiinstitutional Retrospective Review.
PubMed 文献 · AJR Am J Roentgenol · 2025-06-11

本多中心回顾性横断面研究纳入0-18岁疑似中肠旋转不良或肠扭转、以超声作为首项影像检查的儿童,盲法阅片评估超声征象。超声诊断旋转不良敏感度93%、特异度96%(原始报告),盲法复核为97%、99%;诊断肠扭转敏感度97%、特异度98%(原始报告),盲法复核为97%、99%。最准确征象为十二指肠第三部分腹腔内位置(旋转不良,准确率98%)和漩涡征(肠扭转,准确率99%)。作者认为超声可作为一线影像 modality,上消化道造影保留用于 nondiagnostic 或 equivocal 检查。

要点

  • 十二指肠第三部分腹腔内位置是诊断中肠旋转不良最准确征象,准确率98%。
  • 漩涡征是诊断中肠扭转最准确征象,准确率99%。
  • 肠扭转患儿十二指肠近端中位直径13 mm,大于无肠扭转者的6 mm(p < .001)。

核心结论

  • 在诊断性影像检查情境下,超声诊断中肠旋转不良和肠扭转的效能均优异。

研究设计与样本

  • 多中心回顾性横断面研究,纳入2018年1月1日至2021年6月30日以超声作为首项影像检查的0-18岁儿童;旋转不良分析384次检查(中位年龄32天,IQR 5-182天),肠扭转分析900次检查(中位年龄60天,IQR 9-573天);参考标准包括手术、上消化道造影、CT和/或MRI,肠扭转另加临床随访(至少28天);排除 nondiagnostic 和 equivocal 检查。

关键影像表现/征象

  • 十二指肠第三部分位于腹腔内是诊断中肠旋转不良最准确的超声征象,准确率98%。
  • 漩涡征是诊断中肠扭转最准确的超声征象,准确率99%。
  • 肠扭转患儿十二指肠近端中位直径13 mm(IQR 7-18 mm),无肠扭转者为6 mm(IQR 4-8 mm),p < .001。

诊断标准与关键数值

  • 超声诊断中肠旋转不良:原始报告敏感度93%(95% CI 81-98%)、特异度96%(95% CI 92-98%);盲法研究复核敏感度97%(95% CI 87-100%)、特异度99%(95% CI 97-100%)。
  • 超声诊断中肠扭转:原始报告敏感度97%(95% CI 85-100%)、特异度98%(95% CI 96-99%);盲法研究复核敏感度97%(95% CI 86-100%)、特异度99%(95% CI 98-100%)。

临床应用与阅片要点

  • 作者认为超声可作为诊断中肠旋转不良和肠扭转的一线影像 modality。
  • 作者认为上消化道造影保留用于 nondiagnostic 或 equivocal 的超声检查。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. The reported diagnostic performance of ultrasound (US) for midgut malrotation and volvulus varies. OBJECTIVE. The purpose of this study was to evaluate the diagnostic performance of US for midgut malrotation and volvulus separately and to assess individual sonographic signs for each diagnosis. METHODS. This multicenter, retrospective, cross-sectional study included children (who were defined as individuals 0-18 years old) who had US performed as the first imaging test for evaluation of suspected midgut malrotation or volvulus from January 1, 2018, to June 30, 2021. Clinical data were extracted from medical records. Blinded reviewers measured the proximal duodenum and assessed for malrotation and volvulus as well as for specific sonographic signs. Nondiagnostic and equivocal studies were excluded. The reference standards used for malrotation included surgery, upper gastrointestinal (UGI) series, and CT and/or MRI. Volvulus reference standards included the same plus clinical follow-up (minimum, 28 days). Sensitivity, specificity, and accuracy were calculated to evaluate diagnostic performance; the Wilcoxon rank sum test was used to compare median values. RESULTS. Malrotation analysis included 384 examinations; median patient age was 32 days (IQR, 5-182 days). Volvulus analysis included 900 examinations; median patient age was 60 days (IQR, 9-573 days). The sensitivity and specificity of US for malrotation were 93% (95% CI, 81-98%) and 96% (95% CI, 92-98%) by original report and 97% (95% CI, 87-100%) and 99% (95% CI, 97-100%) by blinded research review. The sensitivity and specificity of US for volvulus were 97% (95% CI, 85-100%) and 98% (95% CI, 96-99%) by original report and 97% (95% CI, 86-100%) and 99% (95% CI, 98-100%) by blinded research review. The most accurate sonographic signs were the intraperitoneal position of the third portion of the duodenum for malrotation (accuracy = 98%) and the whirlpool sign for volvulus (accuracy = 99%). The median proximal duodenal diameter was greater in children with volvulus (13 mm [IQR, 7-18 mm] versus 6 mm [IQR, 4-8 mm], p < .001). CONCLUSION. The performance of US for diagnosing both midgut malrotation and volvulus is excellent in the setting of a diagnostic imaging study. CLINICAL IMPACT. US can be used as the first-line imaging modality for diagnosing midgut malrotation and volvulus, with UGI series reserved for nondiagnostic or equivocal examinations.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Nguyen HN, El-Ali AM, Van Tassel D, et al. Diagnostic Performance of Ultrasound for Diagnosing Midgut Malrotation and Volvulus in Children: A Multiinstitutional Retrospective Review. AJR Am J Roentgenol. 2025. PMID: 40499019. doi:10.2214/AJR.25.32660

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。