患者定制触发后延迟与固定触发后延迟优化扫描时机:下肢流出道CT血管成像图像质量与诊断信心的比较

Patient-tailored versus fixed post-trigger delay for optimized scan timing: a comparison of image quality and diagnostic confidence in run-off CT angiography.
PubMed 文献 · Eur Radiol · 2025-06-07

本研究将接受下肢流出道CT血管成像的参与者前瞻性分配至固定触发后延迟(10秒)组或患者定制触发后延迟组,比较图像质量与诊断信心。患者定制组在腘动脉至足动脉的衰减显著更高(均P<0.001),定制延迟范围为8.10至14.90秒,图像噪声无显著差异(P=0.060),多数测量位置的信噪比和对比噪声比更高(均P<0.05),两位放射科医师均评价患者定制组定性图像质量更好、诊断信心不受限的血管段更多。

要点

  • 患者定制触发后延迟范围为8.10至14.90秒,较固定10秒延迟能获得更高的远端动脉衰减。
  • 患者定制组在腘动脉至足动脉的衰减均显著更高(均P<0.001),足动脉衰减在固定组下降89.06 HU(P<0.001)。
  • 两组图像噪声无显著差异(P=0.060),患者定制组在多数测量位置信噪比和对比噪声比更高(均P<0.05)。

核心结论

  • 采用患者定制触发后延迟的团注跟踪可提供可靠的扫描时机,优化血管强化、改善图像质量并提升下肢流出道CT血管成像的诊断信心。

研究设计与样本

  • 前瞻性研究,参与者被分配至固定触发后延迟(10秒)队列或患者定制触发后延迟队列,测量各血管段的衰减、信噪比和对比噪声比,并由两位放射科医师评估定性图像质量和诊断信心。

关键影像表现/征象

  • 患者定制组从腘动脉至足动脉的衰减均显著高于固定组(均P<0.001)。
  • 固定组从腘动脉至足动脉的衰减呈下降趋势,足动脉衰减下降89.06 HU(P<0.001)。
  • 患者定制组图像衰减较固定组更均匀。

诊断标准与关键数值

  • 患者定制触发后延迟范围为8.10至14.90秒,固定触发后延迟为10秒。
  • 患者定制组在多数测量位置的信噪比和对比噪声比高于固定组(均P<0.05)。
  • 两组图像噪声差异无统计学意义(P=0.060)。

临床应用与阅片要点

  • 采用患者定制触发后延迟的团注跟踪可优化从腘动脉至足动脉的血管强化,提升下肢流出道CT血管成像的图像质量和诊断信心。
  • 患者定制触发后延迟可能具有减少对比剂用量的潜力,并可免除从足部到膝部的补偿扫描,从而减少额外辐射暴露。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to validate bolus tracking using a patient-tailored post-trigger delay (PTD) in run-off computed tomography angiography (CTA) and to compare the resulting image quality and diagnostic confidence with those obtained using a fixed PTD.

MATERIALS AND METHODS: Participants were prospectively assigned to either fixed (10 s) or patient-tailored cohorts. We measured attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) for each vascular segment. Two radiologists evaluated qualitative image quality and diagnostic confidence. Differences in quantitative variables between cohorts were assessed using Student's t-test or Mann-Whitney U test, while categorical variables were assessed using chi-square test. Generalized least squares linear regression was used to evaluate the effects of different cohorts, anatomical locations, and their interactions on attenuation.

RESULTS: The patient-tailored cohort showed significantly higher attenuation from the popliteal artery to the foot artery (all p < 0.001), with a patient-tailored PTD ranging from 8.10 to 14.90 s. Generalized least squares linear regression revealed more uniform attenuation in patient-tailored cohort and decreasing attenuation in fixed cohort (decrease of 89.06 HU in foot artery, p < 0.001). There was no significant difference in image noise between cohorts (p = 0.060), while SNR and CNR were higher in the patient-tailored cohort at most measurement locations (all p < 0.05). Both radiologists rated the patient-tailored cohort as having better qualitative image quality and more segment with unrestricted diagnostic confidence.

CONCLUSIONS: Bolus tracking with patient-tailored PTD provides reliable scan timing, resulting in optimized vessel opacification, improved image quality, and enhanced diagnostic confidence in run-off CTA.

KEY POINTS: Question Is this novel bolus tracking algorithm for run-off CT angiography feasible for improving image quality by automatically predicting patient-tailored post-trigger delay (PTD) through real-time monitoring. Findings Patient-tailored PTD improved image quality and distal artery opacification through reliable scan timing, thereby enhancing diagnostic confidence. Clinical relevance Patient-tailored PTD improved image quality, not only demonstrating the potential for reducing contrast media volume but also eliminating the need for compensatory scans from the feet to the knee, thus minimizing additional radiation exposure.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Qi K, Nie K, Bernhard S, et al. Patient-tailored versus fixed post-trigger delay for optimized scan timing: a comparison of image quality and diagnostic confidence in run-off CT angiography. Eur Radiol. 2025. PMID: 40481875. doi:10.1007/s00330-025-11731-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。