儿童和青少年膝关节5分钟以内深度学习超分辨率3T MRI的诊断性能:关节镜验证
本研究回顾性纳入44例接受5分钟以内PIx3-SMSx2加速深度学习超分辨率3T膝关节MRI及关节镜检查的儿童和青少年,评估图像质量与结构异常诊断性能。图像质量总体很好(中位评分5),运动伪影和图像噪声缺失,关节镜验证异常组间一致性良好(κ≥0.74);前交叉韧带撕裂敏感度100%、特异度84%、AUC 0.92,内侧半月板撕裂敏感度71%、特异度97%、AUC 0.84,外侧半月板撕裂敏感度65%、特异度100%、AUC 0.82,盘状外侧半月板AUC 1.00,内侧髌股韧带撕裂AUC 0.98,关节软骨缺损敏感度55%、特异度100%、AUC 0.77。结论认为该方案图像质量优异且对儿童青少年膝关节内部紊乱诊断性能高。
要点
- 5分钟以内PIx3-SMSx2加速深度学习超分辨率3T膝关节MRI图像质量总体很好,运动伪影和图像噪声缺失。
- 前交叉韧带撕裂敏感度100%、特异度84%、AUC 0.92;内侧半月板撕裂敏感度71%、特异度97%、AUC 0.84。
- 外侧半月板撕裂敏感度65%、特异度100%、AUC 0.82;关节软骨缺损敏感度55%、特异度100%、AUC 0.77。
核心结论
- 临床5分钟以内PIx3-SMSx2加速深度学习超分辨率3T膝关节MRI图像质量优异,对儿童和青少年膝关节内部紊乱诊断性能高。
研究设计与样本
- 回顾性纳入2022年10月至2023年12月间接受PIx3-SMSx2加速深度学习超分辨率3T膝关节MRI及关节镜检查的膝关节疼痛儿童和青少年。
关键影像表现/征象
- 总体图像质量中位评分5(IQR 4-5),运动伪影评分5(5-5),图像噪声评分5(4-5)。
- 关节镜验证异常组间一致性良好或更好(κ≥0.74)。
诊断标准与关键数值
- 前交叉韧带撕裂:敏感度100%、特异度84%、准确率93%、AUC 0.92。
- 内侧半月板撕裂:敏感度71%、特异度97%、准确率93%、AUC 0.84。
- 外侧半月板撕裂:敏感度65%、特异度100%、准确率86%、AUC 0.82。
- 盘状外侧半月板:敏感度100%、特异度100%、准确率100%、AUC 1.00。
- 内侧髌股韧带撕裂:敏感度100%、特异度95%、准确率96%、AUC 0.98;关节软骨缺损:敏感度55%、特异度100%、准确率98%、AUC 0.77。
临床应用与阅片要点
- 该方案图像质量总体很好且运动伪影和图像噪声缺失,可用于儿童和青少年膝关节内部紊乱评估。
- 前交叉韧带撕裂和盘状外侧半月板诊断性能高(AUC分别为0.92和1.00),关节软骨缺损敏感度55%但特异度100%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study aims to determine the diagnostic performance of sub-5-min combined sixfold parallel imaging (PIx3)-simultaneous multislice (SMSx2)-accelerated deep learning (DL) super-resolution 3T knee MRI in children and adolescents.
MATERIALS AND METHODS: Children with painful knee conditions who underwent PIx3-SMSx2-accelerated DL super-resolution 3T knee MRI and arthroscopy between October 2022 and December 2023 were retrospectively included. Nine fellowship-trained musculoskeletal radiologists independently scored the MRI studies for image quality and the presence of artifacts (Likert scales, range: 1 = very bad/severe, 5 = very good/absent), as well as structural abnormalities. Interreader agreements and diagnostic performance testing was performed.
RESULTS: Forty-four children (mean age: 15 ± 2 years; range: 9-17 years; 24 boys) who underwent knee MRI and arthroscopic surgery within 22 days (range, 2-133) were evaluated. Overall image quality was very good (median rating: 5 [IQR: 4-5]). Motion artifacts (5 [5-5]) and image noise (5 [4-5]) were absent. Arthroscopy-verified abnormalities were detected with good or better interreader agreement (κ ≥ 0.74). Sensitivity, specificity, accuracy, and AUC values were 100%, 84%, 93%, and 0.92, respectively, for anterior cruciate ligament tears; 71%, 97%, 93%, and 0.84 for medial meniscus tears; 65%, 100%, 86%, and 0.82 for lateral meniscus tears; 100%, 100%, 100%, and 1.00 for discoid lateral menisci; 100%, 95%, 96%, and 0.98 for medial patellofemoral ligament tears; and 55%, 100%, 98%, and 0.77 for articular cartilage defects.
CONCLUSION: Clinical sub-5-min PIx3-SMSx2-accelerated DL super-resolution 3T knee MRI provides excellent image quality and high diagnostic performance for diagnosing internal derangement in children and adolescents.
引用
- Vosshenrich J, Breit HC, Donners R, et al. Arthroscopy-validated diagnostic performance of sub-5-min deep learning super-resolution 3T knee MRI in children and adolescents. Skeletal Radiol. 2025. PMID: 40493057. doi:10.1007/s00256-025-04969-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。