文献速递乳腺MR

简化乳腺MRI鉴别导管内乳头状瘤与导管分泌物的诊断效能

Diagnostic performance of abbreviated breast MRI in differentiating intraductal papilloma from ductal secretion.
PubMed 文献 · Eur J Radiol · 2025-06-01

回顾性纳入62例因超声不确定提示导管内乳头状瘤或导管分泌物而行乳腺MRI的患者,以病理为参考标准,比较简化乳腺MRI与全诊断乳腺MRI的诊断效能。全诊断MRI敏感度87.5%、阳性预测值85.7%,但特异度50%、阴性预测值53.85%;简化MRI诊断效能依观察者而异,观察者间一致性高(Kappa=0.79)。

要点

  • 全诊断乳腺MRI对导管内乳头状瘤敏感度87.5%、阳性预测值85.7%,但特异度仅50%、阴性预测值53.85%。
  • 简化乳腺MRI诊断效能依观察者而异:观察者1敏感度75.0%、特异度57.1%,观察者2敏感度66.67%、特异度57.14%。
  • 简化乳腺MRI观察者间一致性高(Cohen Kappa=0.79),可作为缩短检查时间的替代方案。

核心结论

  • 简化乳腺MRI方案具有中至高度诊断效能和高观察者间一致性,可作为节省时间的替代方案;全诊断MRI在敏感度和诊断准确性上仍更优,但在优先缩短成像时间的临床场景中简化MRI提供了合理替代。

研究设计与样本

  • 回顾性研究,纳入2016年6月至2024年1月因超声不确定提示导管内乳头状瘤或导管分泌物而行乳腺MRI的62例患者,以组织病理学结果为参考标准;两名放射科医师以盲法独立评估简化乳腺MRI方案(包括脂肪抑制平扫T1、首期增强后T1及由全诊断MRI衍生的减影图像),间隔一周后同一两名医师在另一独立时段盲法评估全诊断乳腺MRI。

诊断标准与关键数值

  • 全诊断乳腺MRI检测导管内乳头状瘤的敏感度87.5%、特异度50%、阳性预测值85.7%、阴性预测值53.85%。
  • 观察者1简化乳腺MRI敏感度75.0%、特异度57.1%,与病理比较p=0.0525,与全诊断MRI比较p=0.124。
  • 观察者2简化乳腺MRI敏感度66.67%、特异度57.14%,与病理比较p=0.1945,与全诊断MRI比较p=0.347。
  • 简化乳腺MRI观察者间一致性Cohen Kappa=0.79。

临床应用与阅片要点

  • 全诊断乳腺MRI对导管内乳头状瘤敏感度高但特异度有限,阅片时需注意与腺病纤维化及导管分泌物的鉴别。
  • 简化乳腺MRI诊断效能存在观察者间差异,报告时应结合观察者经验解读。
  • 在优先缩短成像时间的临床场景中,简化乳腺MRI可作为合理替代方案。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic efficacy of abbreviated breast magnetic resonance imaging (AB-MRI) in aiding the differentiation of intraductal papilloma (IDP) from ductal secretion, as compared to full diagnostic breast magnetic resonance imaging (FDB-MRI).

MATERIALS AND METHODS: This retrospective study included patients who underwent breast MRI between June 2016 and January 2024 due to inconclusive ultrasonographic findings suggestive of IDP or ductal secretions, A total of 62 patients were analyzed with histopathological results used as the reference standard. Two radiologists independently reviewed the AB-MRI protocols in a blinded manner. These protocols included fat-suppressed precontrast T1, first postcontrast T1, and subtracted images derived from the FDB-MRI. After a one-week interval, the same radiologists evaluated the FDB-MRI examinations in a separate session, blinded to the AB-MRI results. Diagnostic performance metrics including sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Interobserver agreement for AB-MRI, as well as agreement between AB-MRI and FDB-MRI interpretations, were analyzed using Cohen's kappa test.

RESULTS: The mean age of the 62 patients was 46.05 ± 11.59 years, Histopathological results identified 48 IDPs, 6 cases of adenosis and fibrosis, and 8 cases of ductal secretions. The FDB-MRI demonstrated high sensitivity (87.5 %) and PPV (85.7 %) for IDP detection but limited specificity (50 %) and NPV (53.85 %). The comparison between FDB-MRI and pathology did not reveal a statistically significant difference (p > 0.05). The diagnostic performance of AB-MRI was observer-dependent; for Observer 1, sensitivity and specificity were 75.0 % and 57.1 %, respectively, with no significant difference compared to pathology (p = 0.0525) or FDB-MRI (p = 0.124). For Observer 2, sensitivity and specificity were 66.67 % and 57.14 %, also not significantly different from pathology (p = 0.1945) or FDB-MRI (p = 0.347). Interobserver agreement was high (Cohen's Kappa = 0.79) CONCLUSION: The AB-MRI protocol demonstrated moderate-to-high diagnostic performance and high interobserver agreement as a time-efficient alternative. While the FDB-MRI remains superior in sensitivity and diagnostic accuracy, AB-MRI offers a reasonable alternative in clinical scenarios where shorter imaging time is prioritized, such as in the differentiation of IDPs from ductal secretions.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Güner G, Turgan AH, Emir SN, et al. Diagnostic performance of abbreviated breast MRI in differentiating intraductal papilloma from ductal secretion. Eur J Radiol. 2025. PMID: 40479873. doi:10.1016/j.ejrad.2025.112211

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。