儿童上肢X线摄影的辐射剂量估算
本研究利用包含上肢解剖结构的新型混合计算体模,对大型三级儿童医院按年龄分组的儿童上肢X线摄影进行蒙特卡洛模拟,估算有效剂量与器官剂量。结果显示有效剂量范围为0.01 µSv(3-6岁手/指摄影)至1.13 µSv(1-3岁肱骨摄影),并计算了从剂量面积乘积估算剂量的转换系数。
要点
- 儿童上肢X线摄影有效剂量范围为0.01 µSv(3-6岁手/指)至1.13 µSv(1-3岁肱骨)。
- 所有投照中器官剂量最高的四种组织相同:皮肤、肌肉、骨内膜和红骨髓。
- 研究提供了从剂量面积乘积估算有效剂量和器官剂量的转换系数。
核心结论
- 使用新型改良计算体模模拟儿童上肢X线摄影,显示有效剂量和器官剂量范围较广;本研究报告的剂量可适应于特定机构实践进行粗略估算。
研究设计与样本
- 基于本院临床协议按年龄分组的儿童上肢X线摄影技术采集参数,建立摄影参数与剂量面积乘积的关系,使用新型混合计算体模进行蒙特卡洛模拟。
诊断标准与关键数值
- 有效剂量范围:3-6岁手/指摄影0.01 µSv至1-3岁肱骨摄影1.13 µSv;所有投照中器官剂量最高的组织为皮肤、肌肉、骨内膜和红骨髓;报告了这些器官及乳腺、甲状腺的剂量,并计算了从剂量面积乘积估算有效剂量和器官剂量的转换系数。
临床应用与阅片要点
- 本研究报告的剂量可适应于特定机构实践进行粗略估算;作者未给出具体阅片或报告建议。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Upper extremity radiographic exams have long been considered as a single category with one simplified low-dose estimate, despite covering a variety of body parts. There are limited tools currently available for the simulation/calculation of radiation dose from upper extremity exams.
OBJECTIVE: This study aims to evaluate radiation dose (in terms of effective dose and organ doses) from various types of pediatric upper extremity radiographic exams as performed at a large tertiary care children's hospital using a new set of hybrid computational phantoms that incorporate the anatomy of upper extremities and cover varied patient sexes and ages.
MATERIALS AND METHODS: Technical acquisition parameters were collected for upper extremity exams at our institution according to the age-based categories as defined by clinical protocols. A relationship was established between radiographic acquisition parameters and dose-area product for each category using direct measurements. A new set of computational phantoms with posed upper extremities was introduced and used to run Monte Carlo simulations of patient effective dose and organ doses for all relevant projections.
RESULTS: The calculated effective dose to upper extremities was found to range from 0.01 µSv for a hand/finger radiograph of a 3-6-year-old to 1.13 µSv for a humerus radiograph of a 1-3-year-old. The four tissues with the highest organ dose from all projections were the same: skin, muscle, endosteum, and red marrow. Doses to these organs as well as breast and thyroid were reported, and conversion coefficients to estimate effective dose and organ doses from dose-area product were calculated.
CONCLUSION: Simulations of pediatric upper extremity radiographs using a set of newly-modified computational phantoms present a wide range of effective and organ doses. The doses reported in this study can be adapted to site-specific practices for rough estimations.
引用
- Beaulieu D, Lee C, Kim DS, et al. Radiation dose estimation of pediatric upper extremity radiographs. Pediatr Radiol. 2025. PMID: 40526117. doi:10.1007/s00247-025-06286-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。