文献速递妇产影像介入MR

表观扩散系数直方图分析术前预测高强度聚焦超声治疗子宫肌瘤中期疗效

Histogram analysis of apparent diffusion coefficient for preoperative prediction of mid-term efficacy of high-intensity focused ultrasound in the treatment of uterine fibroids.
PubMed 文献 · Abdom Radiol (NY) · 2025-06-16

回顾性连续收集86例患者共101个子宫肌瘤,在b=1000 s/mm²的DWI图像上逐层勾画ROI获取ADC直方图参数,以术后6个月肌瘤体积缩小率(VRR)≥50%为显著有效组、<50%为非显著有效组。多因素分析显示ADC10th和偏度是独立预测因子,AUC分别为0.678和0.739,两者联合AUC为0.790。

要点

  • ADC直方图参数可用于术前预测HIFU治疗子宫肌瘤的中期疗效。
  • ADC10th和偏度是中期疗效的独立预测因子,联合预测优于单一指标。
  • 以术后6个月VRR≥50%为显著有效,VRR<50%为非显著有效。

核心结论

  • ADC直方图分析有助于术前预测HIFU治疗子宫肌瘤的中期疗效。
  • ADC10th和偏度是HIFU治疗子宫肌瘤中期疗效的独立预测因子,两者联合预测效能优于单一指标。

研究设计与样本

  • 单中心回顾性研究,连续收集86例患者共101个子宫肌瘤。
  • 在b=1000 s/mm²的DWI图像上逐层勾画ROI,获取ADC直方图参数(均值、最大值、最小值、第10、25、50、75、90百分位数及偏度、峰度、熵)。
  • 以术后6个月子宫肌瘤体积缩小率(VRR)为中期疗效指标,VRR≥50%为显著有效组,VRR<50%为非显著有效组。

诊断标准与关键数值

  • 显著有效组42个肌瘤,非显著有效组59个肌瘤。
  • 单因素分析显示ADCmean、ADCmax、ADC10th、ADC25th、偏度、峰度、熵在两组间差异有统计学意义。
  • 多因素分析显示ADC10th和偏度有统计学意义,AUC分别为0.678和0.739,两者联合AUC为0.790。

临床应用与阅片要点

  • 术前ADC直方图分析可用于预测HIFU治疗子宫肌瘤的中期疗效,ADC10th和偏度是独立预测因子,两者联合预测效能更优。

局限性

  • 本研究为单中心回顾性研究。
  • 研究者手动分割病灶。
  • 未对术后病理与本研究结果做进一步分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study was designed to investigate the preoperative prediction of the mid-term efficacy of high-intensity focused ultrasound (HIFU) in the treatment of uterine fibroids by apparent diffusion coefficient (ADC) histogram analysis.

METHODS: Eighty-six patients with a total of 101 uterine fibroids were retrospectively collected consecutively. The region of interest (ROI) was outlined layer by layer on diffusion-weighted imaging (DWI) images with b = 1000 s/mm2 to obtain ADC histogram parameters, including the mean, maximum, minimum, 10th, 25th, 50th, 75th and 90th percentiles as well as skewness, kurtosis, and entropy. The volume reduction rate (VRR) of fibroids at 6 months postoperatively was calculated as an indicator of the mid-term effect, and according to the VRR, the cohort was divided into a markedly effective group (VRR ≥ 50%) and a nonmarkedly effective group (VRR < 50%). Differences in ADC histogram parameters between the markedly effective and nonmarkedly effective groups were analyzed by applying univariate and multivariate binary logistic regression to screen out statistically significant indicators, and the predictive efficacy of the relevant ADC histogram parameters was assessed by receiver operating characteristic (ROC) curves.

RESULTS: The markedly effective group included 42 fibroids, and the noneffective group included 59 fibroids. The results of the univariate analysis showed that ADCmean, ADCmax, ADC10th, ADC25th, skewness, kurtosis, and entropy were significantly different between the two groups. The results of the multivariate analysis showed that ADC10th and skewness were statistically significant indicators, the area under the ROC curve (AUC) was 0.678 and 0.739, respectively, and the combined AUC of the two was 0.790. Major study limitations include: this is a single-center retrospective study, the investigator manually segmented the lesions, and no further analysis of postoperative pathology regarding the findings of the study.

CONCLUSION: ADC histogram analysis helps to preoperatively predict the mid-term efficacy of HIFU in the treatment of uterine fibroids. ADC10th and skewness are independent predictors of the mid-term efficacy of HIFU, and the combined efficacy of the two is superior to that of a single indicator.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Bian X, Sun Q, Ren Q, et al. Histogram analysis of apparent diffusion coefficient for preoperative prediction of mid-term efficacy of high-intensity focused ultrasound in the treatment of uterine fibroids. Abdom Radiol (NY). 2025. PMID: 40522385. doi:10.1007/s00261-025-05055-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。