下膈动脉相关咯血的诊断与栓塞治疗:单中心研究
该单中心回顾性分析从2296例因咯血行支气管动脉栓塞术的患者中选取819例存在下膈动脉(IPA)参与供血者,分析其DSA特征并评估PVA颗粒栓塞的安全性和疗效。36%的咯血患者存在异常IPA,95%的病例病灶位于肺基底段,80%的病例IPA与肺动脉存在交通;术后1个月内26例复发,临床成功率为97%。作者认为肺基底段受累时应评估IPA并考虑PVA颗粒栓塞,IPA栓塞使用100-300 µm PVA颗粒及避免无明确指征时常规抗真菌预防对减少复发至关重要。
要点
- 肺基底段病变的咯血患者中,IPA异常供血常见,DSA上多起自腹主动脉或腹腔动脉且增粗迂曲。
- 80%的异常IPA病例可见与肺动脉的交通,阅片时需注意评估 systemic-to-pulmonary shunt。
- IPA栓塞使用100-300 µm PVA颗粒后1个月内咯血复发26例,临床成功率97%。
核心结论
- IPA可参与咯血供血;肺基底段受累时评估IPA并考虑PVA颗粒栓塞是安全的治疗选择,使用100-300 µm PVA颗粒栓塞IPA及避免无明确指征时常规抗真菌预防对减少咯血复发至关重要。
研究设计与样本
- 单中心回顾性分析,从2296例因咯血行支气管动脉栓塞术的患者中选取819例存在IPA参与供血者,采用DSA评估IPA对病灶的供血及体-肺分流,栓塞后监测咯血复发并记录术后不良事件。
关键影像表现/征象
- 36%的咯血患者存在异常IPA,其中95%的病例病灶位于肺基底段,主要病因为肺部感染。
- 异常IPA多起源于腹主动脉或腹腔动脉,表现为增粗和迂曲。
- 80%的病例异常IPA与肺动脉之间存在连接。
诊断标准与关键数值
- DSA评估IPA对病灶的供血及体-肺分流情况,以明确IPA参与供血。
- 采用PVA颗粒(100-300 µm)栓塞病变动脉,术后1个月内监测咯血复发,临床成功率为97%。
- 术后咯血复发的显著预测因素包括术后血小板、术前凝血酶原时间(PT)、术中PVA颗粒大小及术后抗生素使用。
临床应用与阅片要点
- 肺基底段病变的咯血患者应评估IPA参与供血的可能。
- 作者认为肺基底段受累时考虑PVA颗粒栓塞IPA是安全的治疗方式。
- 作者认为IPA栓塞使用100-300 µm PVA颗粒及避免无明确指征时常规抗真菌预防对减少咯血复发至关重要。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The Inferior phrenic artery (IPA) is a key but often overlooked non-bronchial systemic artery involved in causing hemoptysis.
PURPOSE: To analyze the digital subtraction angiography (DSA) characteristics of IPA involvement in cases of hemoptysis and evaluate the safety and efficacy of polyvinyl alcohol (PVA) particle embolization.
MATERIALS AND METHODS: A retrospective analysis examined clinical data from 819 patients with IPA involvement, selected from 2296 patients who undergoing bronchial artery embolization (BAE) due to the hemoptysis. DSA assessed blood supply from the IPA to the lesion and systemic-to-pulmonary shunts. Hemoptysis recurrence was monitored after embolizing the diseased artery with PVA, and postoperative adverse events were recorded.
RESULTS: In the study, 36% of patients with hemoptysis had abnormal IPA, with basal pulmonary segment lesions in 95% of cases, primarily due to pulmonary infection. IPAs mostly originated from the abdominal aorta or the celiac artery and were hypertrophy and tortuous. In 80% of cases, there were connections with pulmonary arteries. Hemoptysis recurred in 26 patients within a month post-procedure, achieving a 97% clinical success rate. Significant predictors of recurrence included postoperative platelet, preoperative prothrombin time (PT), intraoperative PVA particle size, and postoperative antibiotic administration.
CONCLUSION: IPA can contribute to hemoptysis. When basal pulmonary segment involved, it's crucial to evaluate IPA and consider PVA particle embolization for safe treatment. In patients with IPA-associated hemoptysis, the combination of PVA particles (100-300 µm) in IPA embolization and avoiding the routine antifungal prophylaxis in patients without clear indication for antifungal therapy are vital for minimizing recurrence hemoptysis.
引用
- Luo W, Guo Q, Chu M, et al. Diagnosis and Embolization of Hemoptysis Associated with the Inferior Phrenic Artery: A Single-Center Study. Acad Radiol. 2025. PMID: 40461328. doi:10.1016/j.acra.2025.05.042
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。