文献速递腹部技术与安全MR

自由呼吸混合技术在0.55 T下同时进行腹部形态学与定量成像

Free-Breathing Hybrid Technique for Simultaneous Morphological and Quantitative Abdominal Imaging at 0.55 T.
PubMed 文献 · Invest Radiol · 2026-02-01

本研究提出一种用于0.55 T腹部成像的3D混合技术,可同时采集T2加权与T1加权图像并定量质子密度脂肪分数(PDFF)和R2*。数值模拟优化了径向混合自旋回波-梯度回波采集方案,运动补偿使R2*平均误差从24 s-1降至5 s-1、PDFF平均误差从2.7%降至1.6%。11名志愿者在自由呼吸下成像,混合技术所得PDFF和R2*与传统多回波GRE无显著差异(P>0.05)。

要点

  • 0.55 T下自由呼吸混合TSE-GRE序列可同时获得T2加权形态图像和PDFF、R2*定量图。
  • 运动补偿使R2*平均误差从24 s-1降至5 s-1,PDFF平均误差从2.7%降至1.6%。
  • 混合技术所得PDFF和R2*与传统多回波GRE无显著差异(P>0.05)。

核心结论

  • 混合TSE-GRE采集技术可在0.55 T自由呼吸条件下同时实现形态学成像及PDFF与R2*定量估计。

研究设计与样本

  • 数值模拟优化原型径向混合TSE-GRE采集方案,并行含运动与不含运动的体模实验,11名志愿者在原型0.55 T系统上自由呼吸成像,以呼吸信号行运动补偿重建,并与传统采集方案进行体外和体内比较。

关键影像表现/征象

  • 混合技术生成的T2加权图像肝脾相对对比度与传统成像相当。
  • 自由呼吸采集改善了层面覆盖范围,克服了传统采集方案的屏气限制。

诊断标准与关键数值

  • 运动补偿后R2*平均误差从24 s-1降至5 s-1,PDFF平均误差从2.7%降至1.6%。
  • 混合技术估测的PDFF和R2*与传统多回波GRE无显著差异(P>0.05)。
  • 数值模拟显示R2*估计精度较PDFF更依赖回波时间的选择。

临床应用与阅片要点

  • 在0.55 T自由呼吸腹部成像中,可同时获得T2加权形态图像与PDFF、R2*定量参数。
  • 运动补偿可降低R2*和PDFF估计误差,改善自由呼吸下的定量准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Quantitative proton density fat fraction (PDFF) and R2* estimation at lower field strengths, such as 0.55 T, is challenging due to lower signal-to-noise ratio, reduced fat water chemical shift, and increased T2* relaxation times. In this study, we propose a 3D hybrid technique for abdominal imaging at 0.55 T that enables the simultaneous acquisition of T2-weighted and T1-weighted images and quantification of fat fraction and R2* parameters.

MATERIALS AND METHODS: Numerical simulations were performed to optimize a prototype radial hybrid turbo spin echo gradient echo (TSE-GRE) acquisition scheme for improved PDFF and R2* estimation accuracy. Phantom imaging experiments with and without motion were performed to evaluate the sensitivity of the estimation to external motion. Eleven volunteers were imaged on a prototype 0.55 T system. Data were acquired using the proposed technique under free-breathing conditions, and motion-compensated reconstruction was performed using the respiratory signal from a pilot-tone device. Image contrast and estimation performance were compared with conventional acquisition schemes in vitro and in vivo.

RESULTS: Numerical simulations indicated R2* estimation accuracy was more sensitive to the choice of echo time compared with PDFF. Performing motion compensation reduced the mean error in R2* from 24 to 5 s -1 while the mean error in PDFF only reduced from 2.7% to 1.6%. The proposed technique generated T2-weighted images with comparable relative liver-spleen contrast as conventional imaging and there were no significant differences ( P >0.05) in the PDFF and R2* values estimated from the hybrid technique compared with conventional multi-echo GRE. Further, the free-breathing acquisition allowed improved slice coverage while overcoming breath-hold limitations of conventional acquisition schemes.

CONCLUSIONS: The use of a hybrid TSE-GRE acquisition technique can allow simultaneous morphological and quantitative PDFF and R2* estimation at 0.55 T under free-breathing conditions.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. B Keerthivasan M, Bruno M, Solomon E, et al. Free-Breathing Hybrid Technique for Simultaneous Morphological and Quantitative Abdominal Imaging at 0.55 T. Invest Radiol. 2026. PMID: 40511639. doi:10.1097/RLI.0000000000001214

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。