研究在15只健康新西兰兔肝脏中注射可声响应支架(ARS)以空间限制全氟戊烷液滴,再经聚焦超声汽化产生局限气泡云并造成靶区肝组织机械性损伤;常规超声显示ARS有效限制液滴流动,靶区出现高浓度气泡云,组织病理显示各组均为3级损伤,靶区损伤面积分别为CK960组6.86±2.62mm²、PRO2.1组13.72±6.08mm²、PRO4.1组11.68±9.43mm²,Masson染色示各组靶区白腔结构周围均见明显纤维化。

要点

  • 声响应支架(ARS)联合聚焦超声可在靶区产生局限高浓度气泡云,常规超声2D可显示液滴流动受限。
  • 组织病理显示CK960、PRO2.1、PRO4.1三组靶区均为3级损伤,损伤面积分别为6.86±2.62mm²、13.72±6.08mm²、11.68±9.43mm²。
  • Masson染色示各组靶区白腔结构周围均见明显纤维化。

核心结论

  • ARS在聚焦超声下汽化可在靶区产生集中气泡云,造成靶向肝损伤而不影响周围组织。

研究设计与样本

  • 可行性动物研究,15只健康新西兰兔按换能器分为CK960、PRO2.1、PRO4.1三组,超声引导下于肝中叶注射ARS后行聚焦超声治疗。

关键影像表现/征象

  • 常规超声2D图像显示ARS有效限制全氟戊烷液滴流动,靶区出现局限高浓度气泡云。
  • 大体观察示肝组织靶区空化坏死。
  • HE染色示所有组均为3级病理损伤,靶区损伤面积CK960组6.86±2.62mm²、PRO2.1组13.72±6.08mm²、PRO4.1组11.68±9.43mm²。
  • 所有组均见大小不等的白腔结构,Masson染色示各组靶区白腔结构周围明显纤维化。

诊断标准与关键数值

  • 实现最佳局限高浓度气泡云及靶区机械消融效果的纤维蛋白原最佳浓度为1.47mg/mL。
  • HE染色病理损伤分级:所有组均为3级损伤。

临床应用与阅片要点

  • 常规超声2D可用于观察ARS限制液滴流动及靶区局限高浓度气泡云形成。
  • 阅片时注意靶区白腔结构及周围纤维化,对应HE染色的3级病理损伤。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Histotripsy uses a large array and high peak negative pressure (PNP) for mechanical tissue ablation. Our prior study shows that manual injection of exogenous cavitation nuclei-perfluoropentane (PFP) droplets, substantially lowers the needed PNP. Combined with low-frequency (300-600 kHz) and low-PNP (1-5 MPa) focused ultrasound (FUS), this approach effectively induces mechanical liver tissue damage. However, the high fluidity of PFP droplets leads to bubble cloud dispersion beyond the target zone, potentially causing non-target tissue damage during sustained FUS exposure. To address this issue, we developed an innovative sonoablation strategy utilizing an acoustic droplet vaporization acoustically responsive scaffold (ARS) designed to spatially confine PFP droplets, thereby generating localized bubble clouds strictly within the intended ablation zone.

MATERIALS AND METHODS: 15 healthy New Zealand rabbits were divided into three groups based on different transducers: CK960, PRO2.1, and PRO4.1. ARS is composed of a mixture of fibrinogen solution, DMEM, phase-change perfluoropentane microparticles, and thrombin. ARS were injected into the liver mid-lobe under ultrasound (US), then treated with FUS.

RESULTS: We discovered that the optimal fibrinogen concentration for achieving the best limited high-concentration bubble cloud and mechanical ablation effect with ADV in the target area was 1.47 mg/mL. Conventional US 2D images revealed that ARS effectively restricted the flow of PFP droplets, resulting in localized high-concentration bubble clouds in the target region. Gross observation indicated cavitation necrosis in the liver tissue target area. HE staining showed grade 3 pathological damage across all groups. The damaged areas in the liver target were 6.86±2.62mm2, 13.72±6.08mm2, and 11.68±9.43mm2 for the CK960, PRO2.1, and PRO4.1 groups, respectively. White cavity structures of varying sizes were observed in all groups. Masson staining revealed significant fibrosis surrounding the white cavity structure in the liver tissue target area in all groups.

CONCLUSION: ARS vaporization under FUS in the study produced concentrated bubble clouds in the targeted area, causing targeted liver damage without affecting surrounding tissue.