文献速递腹部技术与安全CT

计算机断层扫描定位胃肠道穿孔的诊断准确性:聚焦胃与十二指肠缺损

Diagnostic accuracy of computed tomography in localizing gastrointestinal perforations: Focusing on gastric and duodenal defects.
PubMed 文献 · Eur J Radiol · 2025-06-03

本研究为单中心回顾性研究,纳入156例经手术证实的胃肠道穿孔患者,评估术前增强腹盆部CT定位穿孔部位的准确性与可重复性。两名专科放射科医师独立阅片,区分胃十二指肠穿孔与其他部位穿孔的准确率分别为94.9%和88.5%(k=0.86),区分胃与十二指肠穿孔的准确率分别为79.6%和64.8%,最小强度投影重建可能作为新的辅助手段。

要点

  • CT区分胃十二指肠穿孔与其他部位穿孔准确率高(94.9%和88.5%,k=0.86)。
  • CT区分胃与十二指肠穿孔准确率相对较低(79.6%和64.8%)。
  • 最小强度投影重建可能提高胃十二指肠穿孔定位准确性,但未达统计学显著。

核心结论

  • CT在定位胃肠道穿孔方面具有高准确性和可重复性,尤其在区分胃与十二指肠缺损这一对手术决策关键的鉴别上。
  • 最小强度投影重建可能作为该场景下一种新的诊断辅助手段。
  • 积液、脂肪条索和壁增厚等CT征象见于大多数穿孔,但均与正确穿孔定位无显著相关性。

研究设计与样本

  • 单中心回顾性研究,纳入经手术证实的胃肠道穿孔且术前行增强腹盆部CT的受试者156例(男/女:89/67;中位年龄62岁)。
  • 两名专科放射科医师独立阅片,使用气体包涵、气腹和胃肠道壁增厚等既定CT征象识别穿孔部位。
  • 对胃十二指肠穿孔,还评估了最小强度投影重建的准确性。
  • 采用Cohen kappa统计量计算阅片者间一致性。

关键影像表现/征象

  • 积液、脂肪条索和壁增厚等CT征象见于大多数穿孔,但无一与正确穿孔定位显著相关。
  • 原文未报告其他影像征象细节。

诊断标准与关键数值

  • CT区分所有穿孔部位的准确性:阅片者1为73.1%,阅片者2为67.9%(k=0.72)。
  • CT区分胃十二指肠穿孔与其他部位穿孔的准确性:阅片者1为94.9%,阅片者2为88.5%(k=0.86)。
  • 胃十二指肠穿孔(n=56;35.9%)中,阅片者1正确区分胃与十二指肠穿孔的比例为79.6%,阅片者2为64.8%。
  • 最小强度投影重建将准确性提高至87%(阅片者1)和77.8%(阅片者2),但无统计学显著性(p=0.47和p=0.21)。

临床应用与阅片要点

  • CT可用于定位胃肠道穿孔,区分胃十二指肠穿孔与其他部位穿孔的准确性高,支持手术决策。
  • 区分胃与十二指肠穿孔的准确性相对较低,阅片时需注意。
  • 最小强度投影重建可能作为辅助手段用于胃十二指肠穿孔定位,但原文未给出推荐等级。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To provide a detailed assessment of the accuracy and reproducibility of Computed Tomography (CT) in localizing gastrointestinal perforations, with a focus on distinguishing gastric and duodenal defects.

METHODS: This single-center retrospective study evaluated subjects with surgically confirmed gastrointestinal perforation who underwent preoperative contrast-enhanced abdominopelvic CT. Two subspecialized radiologists reviewed each CT independently to identify the perforation site, to differentiate gastroduodenal from perforations in other locations, and to differentiate between gastric and duodenal perforation, using defined CT signs such as gas inclusions, pneumoperitoneum, and thickened gastrointestinal walls. For gastroduodenal perforations, accuracy of Minimum Intensity Projection (MinIP) reconstructions was also assessed. Inter-reader agreement was calculated using Cohen's kappa statistics.

RESULTS: 156 patients (M/F: 89/67; median age: 62 years) met inclusion criteria. CT accuracy in distinguishing all perforation sites was 73.1 % for Reviewer 1 and 67.9 % for Reviewer 2 (k = 0.72). When differentiating gastroduodenal from other perforations, accuracy increased to 94.9 % and 88.5 % (k = 0.86). Among gastroduodenal perforations (n = 56; 35.9 %), Reviewer 1 correctly differentiated gastric from duodenal perforation in 79.6 % of cases, and Reviewer 2 in 64.8 %. MinIP imaging increased accuracy to 87 % and 77.8 %, though not significantly (p = 0.47 and p = 0.21).

CONCLUSION: CT demonstrates high accuracy and reproducibility in localizing gastrointestinal perforations, particularly in differentiating gastric from duodenal defects- a critical distinction for surgical decision making. MinIP reconstructions may be useful as a novel diagnostic adjunct in this context. CT signs such as fluid, fat stranding, and wall thickening were seen in most perforations, though none correlated significantly with correct perforation localization.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Pavlovic A, Herrington T, Mijovic K, et al. Diagnostic accuracy of computed tomography in localizing gastrointestinal perforations: Focusing on gastric and duodenal defects. Eur J Radiol. 2025. PMID: 40479874. doi:10.1016/j.ejrad.2025.112192

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。