体素内不相干运动扩散加权成像用于排除肝硬化高危食管静脉曲张
回顾性纳入2015年1月至2021年12月间接受配对食管胃十二指肠镜和上腹部IVIM成像的肝硬化患者244例,高危食管静脉曲张(HREV)占54.1%(132/244)。脾灌注参数f_S、D*_S和D*_L独立预测HREV,f_S的AUROC为0.90,优于其他无创检查,以f_S≤16.1%为阈值排除HREV的漏诊率低于5%,可避免27.0%的食管胃十二指肠镜。
要点
- 脾灌注参数f_S、D*_S和D*_L可独立预测高危食管静脉曲张。
- f_S以≤16.1%为阈值排除HREV时AUROC为0.90,漏诊率低于5%。
- f_S阈值下可避免27.0%的EGD,观察者间重复性优秀。
核心结论
- 脾微循环灌注参数(f_S和D*_S)是排除高危食管静脉曲张、避免不必要EGD的潜在无创标志物。
研究设计与样本
- 回顾性纳入2015年1月至2021年12月间接受配对食管胃十二指肠镜和上腹部IVIM成像的肝硬化患者244例,以EGD为参考标准。
诊断标准与关键数值
- f_S以≤16.1%为阈值排除HREV,AUROC为0.90,可避免27.0%的EGD,漏诊HREV率低于5%;D*_S的AUROC为0.74,D*_L的AUROC为0.73;f_S的NPV在HREV患病率从5%升至50%时仍保持在90%以上。
临床应用与阅片要点
- 作者认为脾微循环灌注参数(f_S和D*_S)是排除HREV、避免不必要EGD的潜在无创标志物。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To explore the role of liver- and spleen-based Intravoxel Incoherent Motion Diffusion-weighted Imaging (IVIM) imaging in ruling out high-risk esophageal varices (HREVs) in patients with cirrhosis and compare it with other noninvasive tests (NITs).
METHODS: Patients with liver cirrhosis who underwent paired Esophagogastroduod-enoscopy (EGD) and upper abdominal IVIM imaging between January 2015 and December 2021 were retrospectively enrolled. Logistic regression analyses were performed to determine the potential predictors of HREVs. The diagnostic performance was estimated with the area under the receiver operating characteristic curve (AUROC). We used the 95% sensitivity to determine the cutoff for ruling out HREVs and compared the spared EGD rate of IVIM imaging with that of NITs. A sensitivity analysis was carried out to assess the impact of the prevalence of HREVs on the negative predictive value (NPV) at given cutoff values.
RESULTS: A total of 244 patients were included, and HREVs were found in 54.1% (132/244) of the patients. The parameters f_S, D*_S and D*_L independently predicted HREVs. Compared with NITs, f_S (AUROC: 0.90) performed significantly better (all p < 0.05), and D*_S (AUROC: 0.74) and D*_L (AUROC: 0.73) performed similarly. f_S (cutoff ≤ 16.1%) had the highest spared EGD rate (27.0%), with a missed HREVs rate of less than 5%, and showed excellent interobserver repeatability. The NPV of f_S remained above 90% as the prevalence of HREVs increased from 5 to 50%.
CONCLUSION: Splenic microcirculatory perfusion parameters (f_S and D*_S) are potential noninvasive markers for ruling out HREVs and avoiding unnecessary EGDs.
引用
- Zhu J, Zhang X, Yi Z, et al. Intravoxel incoherent motion diffusion-weighted imaging for ruling out high-risk esophageal varices in cirrhosis. Abdom Radiol (NY). 2025. PMID: 40481887. doi:10.1007/s00261-025-05020-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。