基于人工智能的肝脏分割评估及其在纵向肝脏体积测量中的应用
回顾性单中心研究评估开源AI肝脏分割模型在平扫及动态增强CT各期相上的准确性,并与专家放射科医师比较;模型在各期相均表现高精度,动脉期DSC最高为0.988±0.010;纵向分析39例无肝病患者的527次CT显示肝脏体积年均下降0.95%。
要点
- AI肝脏分割模型在动脉期、门静脉期及平扫CT均与专家手动分割高度一致,动脉期DSC最高为0.988±0.010。
- 肝脏体积组内相关系数在增强期相超过0.9,平扫CT超过0.8。
- 无肝病人群纵向随访显示肝脏体积年均下降0.95%。
核心结论
- 该AI模型在各CT期相均能高精度分割肝脏,并可纵向追踪年龄相关的肝脏体积减小。
研究设计与样本
- 回顾性单中心研究,评估既往报道的开源AI肝脏分割模型,比较平扫及动态增强CT期相与专家放射科医师分割的准确性;纵向分析纳入39例无肝病患者共527次CT,随访5至20年。
诊断标准与关键数值
- 动脉期DSC最高,为0.988±0.010。
- 肝脏体积组内相关系数在增强期相超过0.9,平扫CT超过0.8。
- 纵向分析显示肝脏体积年均下降0.95%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Accurate liver-volume measurements from CT scans are essential for treatment planning, particularly in liver resection cases, to avoid postoperative liver failure. However, manual segmentation is time-consuming and prone to variability. Advancements in artificial intelligence (AI), specifically convolutional neural networks, have enhanced liver segmentation accuracy. We aimed to identify optimal CT phases for AI-based liver volume estimation and apply the model to track liver volume changes over time. We also evaluated temporal changes in liver volume in participants without liver disease.
METHODS: In this retrospective, single-center study, we assessed the performance of an open-source AI-based liver segmentation model previously reported, using non-contrast and dynamic CT phases. The accuracy of the model was compared with that of expert radiologists. The Dice similarity coefficient (DSC) was calculated across various CT phases, including arterial, portal venous, and non-contrast, to validate the model. The model was then applied to a longitudinal study involving 39 patients without liver disease (527 CT scans) to examine age-related liver volume changes over 5 to 20 years.
RESULTS: The model demonstrated high accuracy across all phases compared to manual segmentation. Among the CT phases, the highest DSC of 0.988 ± 0.010 was in the arterial phase. The intraclass correlation coefficients for liver volume were also high, exceeding 0.9 for contrast-enhanced phases and 0.8 for non-contrast CT. In the longitudinal study, the model indicated an annual decrease of 0.95%.
CONCLUSION: This model provides high accuracy in liver segmentation across various CT phases and offers insights into age-related liver volume reduction. Measuring changes in liver volume may help with the early detection of diseases and the understanding of pathophysiology.
引用
- Kimura R, Hirata K, Tsuneta S, et al. Evaluation of artificial-intelligence-based liver segmentation and its application for longitudinal liver volume measurement. Abdom Radiol (NY). 2025. PMID: 40493176. doi:10.1007/s00261-025-05050-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。