文献速递腹部介入US

弹性成像与动态增强超声在评估胰腺移植排斥反应中的作用

Role of elastography and dynamic contrast-enhanced ultrasound in the evaluation of pancreas transplantation rejection.
PubMed 文献 · Eur Radiol · 2025-06-25

本研究前瞻性纳入56例胰腺移植患者,在移植后1周、3周和12个月进行弹性成像和动态增强超声(DCE-US)检查,并行监测性活检。移植后90天之后,排斥组移植物硬度更高(0.97 vs 1.46 m/s,p < 0.001)且灌注更低;弹性成像最佳截断值为1.27 m/s(AUC 0.80),联合预测评分显示弹性成像和DCE-US改变与23.2倍的排斥概率相关。

要点

  • 移植后90天内弹性成像和DCE-US参数离散度高,此期间诊断价值有限。
  • 移植90天后排斥组硬度更高(0.97 vs 1.46 m/s,p < 0.001)且灌注更低。
  • 弹性成像截断值1.27 m/s(AUC 0.80),联合评分与23.2倍排斥概率相关。

核心结论

  • 移植后90天之后,胰腺移植物排斥与移植物硬度更高和灌注更低相关。

研究设计与样本

  • 前瞻性研究,纳入56例胰腺移植患者,共121次弹性成像和127次DCE-US检查;于移植后1周、3周和12个月进行弹性成像和DCE-US,并于3周和12个月行监测性活检,期间所有 requested 活检同时行弹性成像和DCE-US;根据活检结果分为正常/排斥组,排除其他并发症移植物;建立截断值。

关键影像表现/征象

  • 移植后90天内所有弹性成像和DCE-US参数均呈现高度离散。
  • 移植90天后排斥组移植物硬度更高(0.97 vs 1.46 m/s,p < 0.001)。
  • 移植90天后排斥组移植物灌注更低。

诊断标准与关键数值

  • 弹性成像最佳截断值为1.27 m/s,AUC 0.80。
  • DCE-US峰值增强最佳截断值为601 a.u.,AUC 0.67。
  • DCE-US wash-in AUC最佳截断值为2748 a.u.,AUC 0.70。
  • DCE-US wash-in rate最佳截断值为118 a.u.,AUC 0.65。
  • DCE-US wash-in灌注指数最佳截断值为369 a.u.,AUC 0.67;wash-out AUC最佳截断值为5181 a.u.,AUC 0.69;total AUC最佳截断值为6388 a.u.,AUC 0.68。

临床应用与阅片要点

  • 作者认为这些非侵入性工具可轻松整合到日常常规实践中,可能有助于识别排斥风险较高的移植物,从而允许更密切的随访或早期活检以建立早期排斥治疗,改善移植物和患者生存。

局限性

  • 移植后前90天所有参数均呈现高度离散。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Rejection is the leading cause of graft failure, and its diagnosis remains a challenge. Elastography and dynamic contrast-enhanced ultrasound (DCE-US) are novel non-invasive techniques for quantifying tissue elasticity and perfusion. Their role in pancreas graft rejection has not yet been defined.

MATERIALS AND METHODS: From October 16 to January 20, all pancreas transplantations performed at our institution were prospectively studied with elastography and DCE-US at 1 week, 3 weeks, and 12 months post-transplantation. Surveillance biopsies were performed at 3 weeks and 12 months. Elastography and DCE-US were also conducted in all requested biopsies during this period (regardless of the date of transplantation). Patients were categorized according to the biopsy result: normal/rejection. Grafts with other complications were excluded. Cut-off values were established.

RESULTS: One hundred twenty-one elastography and 127 DCE-US in 56 patients were included. All parameters showed a high dispersion during the first 90 days post-transplantation. After this period, the rejection group presented higher stiffness (0.97 vs 1.46 m/s, p < 0.001) and lower perfusion. The optimal cut-off value for elastography was 1.27 m/s (AUC 0.80), and for DCE-US were: peak enhancement 601 a.u. (AUC 0.67), wash-in AUC 2748 a.u. (AUC 0.70), wash-in rate 118 a.u. (AUC 0.65), wash-in perfusion index 369 a.u. (AUC 0.67), wash-out AUC 5181 a.u. (AUC 0.69) and total AUC 6388 a.u. (AUC 0.68). A combined predictive score showed that alteration of elastography and DCE-US was associated with a 23.2-fold probability of rejection.

CONCLUSION: After the first 90 days post-transplantation, pancreas graft rejection is associated with higher stiffness and lower graft perfusion.

KEY POINTS: Question Pancreas graft rejection remains a clinical challenge, as there are currently no reliable non-invasive tests for its diagnosis. Findings After the first 90 days post-transplantation, elastography and DCE-US show higher stiffness and lower pancreas graft perfusion in the presence of rejection. Clinical relevance These non-invasive tools, which can be easily integrated into daily routine practice, may be useful in identifying grafts at higher risk of rejection, allowing closer follow-up or early biopsy to establish early rejection treatment, improving graft and patient survival.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Bassaganyas C, Ventura-Aguiar P, Sapena V, et al. Role of elastography and dynamic contrast-enhanced ultrasound in the evaluation of pancreas transplantation rejection. Eur Radiol. 2025. PMID: 40560414. doi:10.1007/s00330-025-11772-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。