改良CT严重指数在儿童急性胰腺炎预后评估中的应用价值
本研究为单中心回顾性研究,纳入2019年1月至2024年12月接受腹部和盆腔增强CT的47例急性胰腺炎患儿,评估改良CT严重指数(mCTSI)预测临床结局的价值。发生器官功能障碍的患儿mCTSI中位数高于未发生者(8 vs 4,P<0.001);mCTSI预测器官功能障碍的AUC为0.891,优于CRP的0.596(P=0.002),与CTSI无显著差异。
要点
- mCTSI≥4分(中重度)患儿PICU住院时间中位数较mCTSI<4分者更长(3天 vs 0天,P<0.001)。
- mCTSI预测器官功能障碍的AUC为0.891(95%CI 0.799-0.983)。
- mCTSI与CTSI预测器官功能障碍无显著差异,二者均优于CRP。
核心结论
- mCTSI和CTSI均有助于预测儿童急性胰腺炎的临床结局,且在预测器官功能障碍方面均优于CRP水平。
研究设计与样本
- 单中心回顾性研究,纳入2019年1月至2024年12月诊断为急性胰腺炎并接受腹部和盆腔增强CT的47例患儿,比较mCTSI、CTSI和入院48小时CRP水平预测器官功能障碍的表现。
诊断标准与关键数值
- 发生器官功能障碍患儿mCTSI中位数为8(IQR 6-10),未发生者为4(IQR 2-6),P<0.001。mCTSI预测器官功能障碍的AUC为0.891(95%CI 0.799-0.983),CRP的AUC为0.596(95%CI 0.433-0.759),两者比较P=0.002。mCTSI与CTSI之间无显著差异。mCTSI≥4分(中重度)患儿PICU住院时间中位数为3天(IQR 0-9),mCTSI<4分者为0天(IQR 0-0),P<0.001。
临床应用与阅片要点
- 原文结论指出mCTSI和CTSI均有助于预测儿童急性胰腺炎的临床结局,且在预测器官功能障碍方面均优于CRP水平。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The ability to predict severe pancreatitis in children remains a challenge, and limited evidence exists in the literature regarding the utility of different prognostication systems.
OBJECTIVES: To assess the utility of the modified computed tomography severity index (mCTSI) in predicting clinical outcomes in paediatric patients with acute pancreatitis.
MATERIALS/METHODS: A single-centre, retrospective review of all patients diagnosed with acute pancreatitis who underwent contrast-enhanced computed tomography of the abdomen and pelvis from January 2019 to December 2024. The performance in predicting the development of organ dysfunction of mCTSI, computed tomography severity index (CTSI), and C-reactive protein (CRP) level at 48 h of admission was compared.
RESULTS: We included 47 patients. Patients who developed organ dysfunction had a higher median mCTSI (8 [interquartile range, IQR 6-10]) compared to those who did not (4 [IQR 2-6], P < 0.001). In patients who had mCTSI ≥ 4, i.e. moderate and severe grades, the median length of PICU stay was significantly longer (mCTSI < 4 = 0 [IQR 0-0] days; mCTSI ≥ 4 = 3 [IQR 0-9] days, P < 0.001). Receiver operating characteristic analysis demonstrated mCTSI as a better predictor of organ dysfunction with an area under curve (AUC) of 0.891 (95% confidence interval [CI] 0.799-0.983), compared to CRP level which had an AUC of 0.596 (95% CI 0.433-0.759) (P = 0.002). No significant difference was identified between mCTSI and CTSI.
CONCLUSIONS: Both mCTSI and CTSI were useful in predicting the clinical outcome of patients with acute pancreatitis and performed better than CRP level in predicting the development of organ dysfunction.
引用
- Chiu HW, Fung KFK, Leung CLY, et al. Utility of the modified computed tomography severity index in prognostication of acute pancreatitis in children. Pediatr Radiol. 2025. PMID: 40531202. doi:10.1007/s00247-025-06298-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。