文献速递外周血管心血管胸部CT

人工智能在主动脉夹层检测与分型中的作用:现状如何?一项系统综述与Meta分析

Role of Artificial Intelligence in Detecting and Classifying Aortic Dissection: Where Are We? A Systematic Review and Meta-Analysis.
PubMed 文献 · Radiol Cardiothorac Imaging · 2025-01-01

该系统综述与Meta分析检索2010年1月至2023年10月四个数据库,纳入13项原研究,评估人工智能模型在CT图像上检测和分类主动脉夹层的诊断性能。单变量分析估计AI检测敏感度为94%(95%CI:88,97)、特异度为88%(95%CI:79,94),双变量分析AUC为0.97(95%CI:0.95,0.99);仅3项研究按Stanford标准进行分型。结论认为AI可检测主动脉夹层,但当前形式尚不具备临床适用性。

要点

  • AI检测主动脉夹层的汇总敏感度为94%(95%CI:88,97),汇总特异度为88%(95%CI:79,94)。
  • 对比增强CT亚组敏感度97%、特异度93%、AUC 0.98;非对比CT亚组敏感度91%、特异度84%、AUC 0.95。
  • 13项研究中仅3项报告按Stanford标准分型的算法,多数研究质量低且偏倚风险高。

核心结论

  • AI可检测主动脉夹层,但以当前形式尚未展示出临床适用性。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、Web of Science、Embase和Medline自2010年1月至2023年10月发表的文章,纳入所有原研究,共识别13项研究。

关键影像表现/征象

  • 大多数研究以对比增强CT(n=9)作为模型输入,其余研究以非对比CT作为模型输入。
  • 仅3项研究提出了按Stanford标准对主动脉夹层进行分类的算法。

诊断标准与关键数值

  • 单变量分析:AI检测主动脉夹层的汇总敏感度为94%(95%CI:88,97;P=0.049),汇总特异度为88%(95%CI:79,94;P<0.001)。
  • 双变量分析:总体AUC为0.97(95%CI:0.95,0.99;P=0.49)。
  • 对比增强CT亚组:敏感度97%(95%CI:81,100;P=0.007),特异度93%(95%CI:87,97;P<0.001),AUC 0.98(95%CI:0.93,0.99;P=0.09)。
  • 非对比CT亚组:敏感度91%(95%CI:83,96;P=0.33),特异度84%(95%CI:69,93;P<0.001),AUC 0.95(95%CI:0.90,0.99;P=0.14)。
  • 证据质量采用基于METhodological RadiomICs Score(METRICS)和Checklist for Artificial Intelligence in Medical Imaging(CLAIM)清单的复合工具评估,偏倚风险采用Quality Assessment of Diagnostic Accuracy Studies 2(QUADAS-2)工具评估。

局限性

  • 大多数研究质量低且偏倚风险高。
  • 仅3项研究提出了按Stanford标准对主动脉夹层进行分类的算法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate the diagnostic performance of artificial intelligence (AI) models in detecting and classifying aortic dissection (AD) from CT images through a systematic review and meta-analysis. Materials and Methods PubMed, Web of Science, Embase, and Medline were searched for articles published from January 2010 to October 2023. All primary studies were included. Quality of evidence was assessed using a composite tool based on the METhodological RadiomICs Score (ie, METRICS) and Checklist for Artificial Intelligence in Medical Imaging (ie, CLAIM) checklists, and risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (ie, QUADAS-2) tool. Univariate and bivariate meta-analyses were performed assessing individual and joint estimates of sensitivity and specificity. Results Thirteen studies were identified, with most using contrast-enhanced CT (CECT) imaging (n = 9) and the remainder using noncontrast CT (NCCT) imaging as their model input. Only three studies presented algorithms classifying AD by Stanford criteria. Univariate analysis of AI detection performance estimated sensitivity at 94% (95% CI: 88, 97; P = .049) and specificity at 88% (95% CI: 79, 94; P < .001). Bivariate analysis showed good overall model performances (area under the receiver operating characteristic curve [AUC], 0.97 [95% CI: 0.95, 0.99]; P = .49). Subgroup analyses revealed good performance for models using CECT images (sensitivity, 97% [95% CI: 81, 100; P = .007]; specificity, 93% [95% CI: 87, 97; P < .001]; AUC, 0.98 [95% CI: 0.93, 0.99; P = .09]) and NCCT images (sensitivity, 91% [95% CI: 83, 96; P = .33); specificity, 84% [95% CI: 69, 93; P < .001); AUC, 0.95 [95% CI: 0.90, 0.99; P = .14]). Most studies were of low quality and had high risk of bias. Conclusion AI can feasibly detect AD but does not demonstrate clinical applicability in its current form. Keywords: CT, Vascular, Cardiac, Aorta, Computer-aided Diagnosis (CAD), Meta-Analysis Supplemental material is available for this article. © RSNA, 2025.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Asif A, Alsayyari M, Monekosso D, et al. Role of Artificial Intelligence in Detecting and Classifying Aortic Dissection: Where Are We? A Systematic Review and Meta-Analysis. Radiol Cardiothorac Imaging. 2025. PMID: 40503985. doi:10.1148/ryct.240353

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。