文献速递胸部CT

基于CT的影像组学模型预测肺癌气道播散:系统评价与Meta分析

CT-based radiomics models for predicting spread through air space in lung cancer: A systematic review and meta-analysis.
PubMed 文献 · Eur J Radiol · 2025-06-18

该系统评价与Meta分析纳入17项研究共6254例患者,评估基于术前CT的影像组学预测肺癌气道播散(STAS)的诊断准确性,汇总敏感度0.82、特异度0.76、AUC 0.86;在11组配对数据中,影像组学模型AUC 0.86优于临床模型AUC 0.80(p < 0.001)。作者认为CT影像组学可用于术前预测STAS,但需进一步开展大规模、多中心、前瞻性研究。

要点

  • 基于术前CT的影像组学预测肺癌STAS的汇总敏感度0.82、特异度0.76、AUC 0.86。
  • 配对比较中影像组学模型AUC 0.86优于临床模型AUC 0.80(p < 0.001)。
  • 纳入17项研究共6254例,方法学质量为中等。

核心结论

  • CT影像组学预测肺癌STAS具有中等诊断准确性,汇总AUC为0.86,配对比较中优于临床模型(AUC 0.86 vs 0.80,p < 0.001),作者认为可用于术前预测STAS,但需进一步开展大规模、多中心、前瞻性研究。

研究设计与样本

  • 系统评价与Meta分析,检索截至2024年1月前发表的原创研究,纳入17项使用基于CT的影像组学术前预测肺癌患者STAS的研究,共6254例参与者,Meta分析包含26个数据集,两名研究者独立提取数据并评估方法学质量,方法学质量为中等。

诊断标准与关键数值

  • 基于CT的影像组学预测肺癌STAS的汇总敏感度0.82(95%CI: 0.78, 0.86)、特异度0.76(95%CI: 0.72, 0.80)、AUC 0.86(95%CI: 0.83, 0.89);在11组配对比较数据集中,影像组学模型AUC 0.86(95%CI: 0.83, 0.89)高于临床模型AUC 0.80(95%CI: 0.76, 0.85),p < 0.001。

临床应用与阅片要点

  • 作者认为,基于CT的影像组学因具有中等诊断准确性、广泛可用和低成本的特点,可用于术前预测肺癌STAS;原文未据此给出具体阅片或报告推荐。

局限性

  • 纳入研究的方法学质量为中等。
  • 作者指出需进一步开展大规模、多中心、前瞻性设计的研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Numerous studies have developed and validated models to predict spread through air space (STAS) in lung cancer using preoperative computed tomography (CT), yielding inconsistent results. We aimed to estimate the diagnostic accuracy of CT-based radiomics for predicting spread through air space (STAS) for preoperative prediction of lung cancer.

MATERIALS AND METHODS: Original studies published prior to January 2024 were searched in various databases. Only studies that used CT-based radiomics to preoperatively predict STAS in lung cancer patients were included. Two researchers independently extracted data and assessed the methodological quality of the included studies. We estimated summary sensitivity (SEN), specificity (SPE), and the areas under the receiver operating characteristic curve (AUC) of CT-based radiomics for predicting STAS. A head-to-head comparison was performed to evaluate the efficacy of clinical and radiomics models.

RESULTS: A total of 17 studies with 6254 participants were included, and the methodological quality was found to be moderate. The meta-analysis comprised 26 datasets and achieved a pooled SEN of 0.82 (95 % CI: 0.78, 0.86), SPE of 0.76 (95 % CI: 0.72, 0.80), and AUC of 0.86 (95 % CI: 0.83, 0.89). In 11 pairwise comparison datasets, the radiomics model outperformed the clinical model with a higher AUC of 0.86 (95 % CI: 0.83, 0.89) compared to 0.80 (95 % CI: 0.76, 0.85), p < 0.001.

CONCLUSIONS: Due to its moderate diagnostic accuracy, widespread use, and low cost, CT-based radiomics can be used to predict STAS in lung cancer preoperatively. However, further research is required in a large, multicentre, and prospective design.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Chen L, Lan X, Huang Y, et al. CT-based radiomics models for predicting spread through air space in lung cancer: A systematic review and meta-analysis. Eur J Radiol. 2025. PMID: 40540954. doi:10.1016/j.ejrad.2025.112249

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。