基于影像组学与CT特征列线图预测≤2 cm浸润性腺癌脏层胸膜侵犯:多中心研究
回顾性收集广西三家三级医院457例≤2 cm浸润性肺腺癌,按254例训练、112例验证、91例测试分组;胸膜凹陷(P<0.05)、胸膜增厚(P<1e-04)、肿瘤直径(P<0.001)为CT模型预测脏层胸膜侵犯的危险因素。基于CT模型与GPTA影像组学模型构建列线图,训练、验证、测试组AUC分别为0.86、0.84、0.86,校准曲线与决策曲线显示列线图优于传统CT特征和影像组学研究。
要点
- 胸膜凹陷、胸膜增厚、肿瘤直径是≤2 cm浸润性肺腺癌脏层胸膜侵犯的CT危险因素。
- 基于CT模型与GPTA影像组学特征构建的列线图训练、验证、测试组AUC为0.86、0.84、0.86。
- 校准曲线与决策曲线分析显示列线图优于传统CT特征和影像组学研究。
核心结论
- 结合CT特征与影像组学特征的列线图对预测≤2 cm浸润性肺腺癌脏层胸膜侵犯具有较高诊断价值。
研究设计与样本
- 回顾性研究,收集广西三家三级医院457例≤2 cm浸润性肺腺癌,分为训练组254例、验证组112例、测试组91例;从CT图像提取大体肿瘤区、瘤周区、大体瘤周区影像组学特征并构建模型。
关键影像表现/征象
- 胸膜凹陷(P<0.05)、胸膜增厚(P<1e-04)、肿瘤直径(P<0.001)被确定为CT模型预测脏层胸膜侵犯的危险因素。
- 从1226个影像组学特征中,GTA、PTA、GPTA模型分别选出5、13、12个最优特征,各模型间AUC值无差异。
诊断标准与关键数值
- 列线图训练组AUC为0.86、验证组AUC为0.84、测试组AUC为0.86。
- 基于AUC值,将CT模型与GPTA模型特征联合构建预测列线图。
临床应用与阅片要点
- 列线图较单一模型表现出更好的准确度、特异度和AUC值。
- 校准曲线和决策曲线分析显示列线图优于传统CT特征和影像组学研究,可提供更大临床获益。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To explore the value of a nomogram based on radiomics and computed tomography (CT) features for preoperative prediction of visceral pleural invasion (VPI) of subpleural, small (≤2 cm) invasive adenocarcinoma (IAC) of the lung.
METHODS: For this retrospective study, 457 cases of invasive lung adenocarcinoma ≤ 2 cm were collected from three tertiary hospitals in Guangxi and used in a training group (n = 254), validation group (n = 112), and test group (n = 91). Risk factors for IAC VPI were screened by univariate and multivariate logistic regression analyses, and a CT model was constructed. Radiomics features of regions representing the gross tumor area (GTA), peritumor area (PTA), and gross peritumor area (GPTA) were extracted from CT images, and the optimal feature subsets based on radiomics score were selected to construct three radiomics models. A combination model was then constructed from the radiomics model with the optimal radiomics score and the CT model and visualized by nomogram. Model performance was analyzed by receiver operating characteristic curve analysis and DeLong test.
RESULTS: Pleural indentation (P < 0.05), pleural thickening (P < 1e-04), and tumor diameter (P < 0.001) were identified as risk factors of the CT model for predicting VPI of IAC. Among 1226 radiomics features, 5, 13, and 12 optimal features were selected for the GTA, PTA, and GPTA models, respectively, and the area under the curve (AUC) values did not differ among these models. Based on AUC values, the CT model and GPTA model features were combined to construct the predictive nomogram. Compared with the individual models, the nomogram exhibited better accuracy, specificity, and AUC values (AUC values for training, verification, and test groups were 0.86, 0.84, and 0.86, respectively). Calibration curve and decision curve analyses showed that the nomogram outperformed traditional CT features and radiomics studies, and could offer greater clinical benefit.
CONCLUSIONS: The developed nomogram combining CT and radiomics features shows high diagnostic value for VPI prediction of IAC of the lung.
引用
- Huang R, Zhao C, Yang J, et al. Nomogram based on radiomics and CT features for predicting visceral pleural invasion of invasive adenocarcinoma ≤ 2 cm: A multicenter study. Eur J Radiol. 2025. PMID: 40532591. doi:10.1016/j.ejrad.2025.112227
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。