文献速递胸部CT

对比增强对自动定量CT测量中诊断间质性肺异常的影响

Effect of contrast enhancement on diagnosis of interstitial lung abnormality in automatic quantitative CT measurement.
PubMed 文献 · Eur Radiol · 2025-06-03

回顾性分析1134例有配对平扫与增强胸部CT的患者,用深度学习自动软件定量间质性肺异常(ILA),以Fleischner学会定义为参考标准。增强扫描测得的非纤维化ILA体积略大(平均差-0.2%),纤维化ILA体积不变(0.0%);平扫与增强扫描间一致性为κ=0.75,两者与放射科医师的一致性分别为κ=0.46和κ=0.54。平扫与增强扫描诊断ILA的敏感度(32.5% vs 42.5%,p=0.221)和特异度(99.8% vs 99.5%,p=0.248)无显著差异。

要点

  • 增强扫描较平扫测得的非纤维化ILA体积略大(平均差-0.2%),纤维化ILA体积不变(0.0%)。
  • 平扫与增强扫描自动定量诊断ILA的一致性为κ=0.75,但与放射科医师的一致性仅κ=0.46和κ=0.54。
  • 放射科医师对因单侧异常而定性不确定的ILA重新分类后,平扫和增强扫描的敏感度分别提高至67.5%和75.0%。

核心结论

  • 在一致性及诊断性能方面,对增强扫描应用自动定量似乎可接受;但放射科医师可能需要通过重新分类定性不确定的ILA来提高敏感度。

研究设计与样本

  • 回顾性分析2017年4月至2020年12月因胸外科手术行胸部CT的患者,共纳入1134例有配对平扫与增强扫描的患者,使用基于深度学习的自动软件定量ILA,以Fleischner学会定义结合定量结果或放射科医师评估为参考标准。

诊断标准与关键数值

  • ILA诊断参考标准为Fleischner学会定义,依据自动定量结果或放射科医师评估分类为ILA或非ILA。
  • 平扫与增强扫描诊断ILA的敏感度分别为32.5%和42.5%(p=0.221),特异度分别为99.8%和99.5%(p=0.248)。
  • 平扫与增强扫描间诊断一致性κ=0.75;平扫与放射科医师一致性κ=0.46,增强扫描与放射科医师一致性κ=0.54。
  • 放射科医师重新分类后,平扫和增强扫描的敏感度分别为67.5%和75.0%。

临床应用与阅片要点

  • 自动定量在增强扫描上测量非纤维化ILA体积较平扫略大(平均差-0.2%),纤维化ILA体积不变(0.0%)。
  • 平扫和增强扫描自动定量与放射科医师评估的一致性均为中等(κ=0.46和κ=0.54),放射科医师对单侧异常所致定性不确定的ILA重新分类可提高敏感度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the effect of contrast enhancement on the diagnosis of interstitial lung abnormalities (ILA) in automatic quantitative CT measurement in patients with paired pre- and post-contrast scans.

MATERIALS AND METHODS: Patients who underwent chest CT for thoracic surgery between April 2017 and December 2020 were retrospectively analyzed. ILA quantification was performed using deep learning-based automated software. Cases were categorized as ILA or non-ILA according to the Fleischner Society's definition, based on the quantification results or radiologist assessment (reference standard). Measurement variability, agreement, and diagnostic performance between the pre- and post-contrast scans were evaluated.

RESULTS: In 1134 included patients, post-contrast scans quantified a slightly larger volume of nonfibrotic ILA (mean difference: -0.2%), due to increased ground-glass opacity and reticulation volumes (-0.2% and -0.1%), whereas the fibrotic ILA volume remained unchanged (0.0%). ILA was diagnosed in 15 (1.3%), 22 (1.9%), and 40 (3.5%) patients by pre- and post-contrast scans and radiologists, respectively. The agreement between the pre- and post-contrast scans was substantial (κ = 0.75), but both pre-contrast (κ = 0.46) and post-contrast (κ = 0.54) scans demonstrated moderate agreement with the radiologist. The sensitivity for ILA (32.5% vs. 42.5%, p = 0.221) and specificity for non-ILA (99.8% vs. 99.5%, p = 0.248) were comparable between pre- and post-contrast scans. Radiologist's reclassification for equivocal ILA due to unilateral abnormalities increased the sensitivity for ILA (67.5% and 75.0%, respectively) in both pre- and post-contrast scans.

CONCLUSION: Applying automated quantification on post-contrast scans appears to be acceptable in terms of agreement and diagnostic performance; however, radiologists may need to improve sensitivity reclassifying equivocal ILA.

KEY POINTS: Question The effect of contrast enhancement on the automated quantification of interstitial lung abnormality (ILA) remains unknown. Findings Automated quantification measured slightly larger ground-glass opacity and reticulation volumes on post-contrast scans than on pre-contrast scans; however, contrast enhancement did not affect the sensitivity for interstitial lung abnormality. Clinical relevance Applying automated quantification on post-contrast scans appears to be acceptable in terms of agreement and diagnostic performance.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Choi J, Ahn Y, Kim Y, et al. Effect of contrast enhancement on diagnosis of interstitial lung abnormality in automatic quantitative CT measurement. Eur Radiol. 2025. PMID: 40459739. doi:10.1007/s00330-025-11715-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。