回顾性分析45例中耳或外耳道胆脂瘤患者的双层探测器光谱CT图像,比较胆脂瘤组织与非胆脂瘤组织的多参数光谱特征。λHU、CT40 keV和Zeff在两组间差异有统计学意义,AUC分别为0.839、0.856和0.869;主观诊断准确率89.8%,敏感度82.86%,特异度93.33%。

要点

  • λHU、CT40 keV和Zeff对胆脂瘤与非胆脂瘤组织有鉴别价值,AUC分别为0.839、0.856、0.869。
  • DLCT主观诊断胆脂瘤的准确率89.8%,敏感度82.86%,特异度93.33%。
  • DLCT主观诊断与术中所见一致性Kappa值为0.809。

核心结论

  • 双层探测器光谱CT在颞骨胆脂瘤定位诊断中表现出较高准确性,对术前评估胆脂瘤病变有显著潜力,可辅助外科医生选择最佳手术入路。

研究设计与样本

  • 回顾性分析2024年5月至2025年3月间收集的45例中耳或外耳道胆脂瘤患者的双层探测器光谱CT图像。
  • 以组织学和手术确认的成分作为参考标准,将光谱CT图像上感兴趣区对应病变与术中记录的胆脂瘤累及范围进行对照。

关键影像表现/征象

  • 在光谱CT图像上对不同解剖部位的相应病变(胆脂瘤组织与非胆脂瘤组织如胆固醇肉芽肿和炎性液体)放置感兴趣区。
  • 记录每个感兴趣区的常规CT值(CTconv)、40 keV单能CT值(CT40 keV)、有效原子序数(Zeff)、电子密度(ED)和40-80keV斜率(λHU),用于比较不同解剖部位不同病理成分的DLCT参数。

诊断标准与关键数值

  • λHU、CT40 keV和Zeff在胆脂瘤组与非胆脂瘤组间差异有统计学意义,AUC分别为0.839、0.856和0.869。
  • DLCT对胆脂瘤病变的主观诊断准确率为89.8%,敏感度82.86%,特异度93.33%,阳性预测值86.14%,阴性预测值91.59%。
  • DLCT主观诊断与术中所见的一致性Kappa值为0.809。
  • CTconv和ED在两组间无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Accurate early localization of temporal bone cholesteatoma is essential for determining the most appropriate surgical approach. Dual-layer detector spectral CT (DLCT) with multi-parameter spectral imaging has significantly improved soft tissue resolution. This study aims to investigate the value of dual-layer detector spectral CT multimodal parameters in the localization diagnosis of cholesteatoma of the temporal bone.

MATERIALS AND METHODS: A retrospective analysis was conducted on dual-layer spectral CT images of 45 patients with middle ear or external auditory canal cholesteatoma, collected between May 2024 and March 2025. The surgeon recorded the extent of cholesteatoma involvement during surgery. Regions of interest (ROIs) were placed on corresponding lesions in different anatomical locations on the spectral CT images, including cholesteatoma tissue and non-cholesteatoma tissues (such as cholesterol granulomas and inflammatory fluids). These lesions were then compared to the histologically and surgically confirmed components at the same anatomical sites. For each ROI, conventional CT value (CTconv), the 40 keV single-energy CT value (CT40 keV), effective atomic number (Zeff), electron density (ED), and the 40-80keV slope (λHU) were recorded and used to compare the DLCT parameters of different pathological components at various anatomical sites.

RESULT: A total of 45 cholesteatoma patients were included in this study, comprising 106 cholesteatoma lesions and 70 non-cholesteatoma lesions. The λHU, CT40 keV, and Zeff showed statistically significant differences between the two groups and demonstrated optimal diagnostic performance, with AUC values of 0.839, 0.856, and 0.869, respectively. The subjective diagnostic accuracy of DLCT for cholesteatoma lesions was 89.8%, with a sensitivity of 82.86%, specificity of 93.33%, positive predictive value (PPV) of 86.14%, and negative predictive value (NPV) of 91.59%. The Kappa value for the agreement with intraoperative findings was 0.809. No significant difference was observed in CTconv and ED between the two groups.

CONCLUSION: Dual-layer detector spectral CT demonstrates high accuracy in the locational diagnosis of temporal bone cholesteatoma. It has significant potential for preoperative evaluation of cholesteatoma lesions, assisting surgeons in selecting the optimal surgical approach.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Wang J, Liu Y, Ma X, et al. Accuracy of Dual-layer Detector Spectral CT in Localizing Cholesteatoma: An Advanced Imaging Perspective. Acad Radiol. 2025. PMID: 40494697. doi:10.1016/j.acra.2025.05.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。