文献速递神经儿科影像技术与安全US

超声测量视神经鞘直径与有创颅内压监测诊断儿童颅内高压的准确性比较

Diagnostic accuracy of ultrasonographic optic nerve sheath diameter compared to invasive ICP monitoring for intracranial hypertension in pediatric patients.
PubMed 文献 · Pediatr Radiol · 2025-06-17

该系统评价纳入7项研究共380例患儿,比较超声测量视神经鞘直径与有创颅内压监测的诊断准确性。以20 mmHg为阈值时敏感度为91.6%、特异度为71.9%;以15 mmHg为阈值时敏感度为89.3%、特异度为76.2%。20 mmHg阈值下年龄亚组敏感度差异有统计学意义,>1岁患儿敏感度90.1%,<1岁患儿敏感度75.7%。

要点

  • 超声测量视神经鞘直径诊断儿童颅内高压的敏感度较高,20 mmHg阈值下为91.6%。
  • 20 mmHg阈值下>1岁患儿敏感度90.1%,<1岁患儿敏感度75.7%,年龄亚组差异有统计学意义(P=0.03)。
  • 各研究采用的视神经鞘直径截断值范围为4.0 mm至5.29 mm。

核心结论

  • 超声测量视神经鞘直径在儿童中检测颅内高压的诊断准确性较高,但敏感度随年龄变化,凸显了按年龄分层分析评估视神经鞘直径准确性的重要性,尤其在婴儿中。

研究设计与样本

  • 系统评价与Meta分析,检索PubMed、Embase和Cochrane数据库自建库至2025年2月3日,纳入比较超声测量视神经鞘直径与有创颅内压测量(mmHg)的儿童前瞻性或回顾性队列及随机试验,共纳入7项研究380例患者,采用随机效应模型。

诊断标准与关键数值

  • 20 mmHg阈值(n=369)下敏感度91.6%[95%CI,83.2-96.0]、特异度71.9%[95%CI,65.4-77.6];15 mmHg阈值(n=304)下敏感度89.3%[95%CI,83.9-93.1]、特异度76.2%[95%CI,68.0-82.8];各研究视神经鞘直径截断值为4.0 mm至5.29 mm。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Monitoring intracranial pressure (ICP) is essential in pediatric neurocritical care, but invasive methods pose risks, highlighting the need for accurate non-invasive alternatives like ultrasonographic optic nerve sheath diameter (ONSD) measurement.

OBJECTIVE: To evaluate the diagnostic accuracy of ultrasonographic measurement of the ONSD for detecting elevated ICP in children, stratified by age (< 1 year or > 1 year).

MATERIALS AND METHODS: A systematic search was conducted in PubMed, Embase, and Cochrane from inception to February 3, 2025. Eligible studies included prospective or retrospective cohorts and randomized trials comparing ultrasonographic ONSD with invasive ICP measurements (mmHg) in pediatric patients, reporting data for a 2 × 2 table. The analyses included (1) sensitivity; (2) specificity; (3) summary receiver operating characteristic curve; (4) area under the curve; (5) diagnostic odds ratio; and (6) likelihood ratios. A random-effects model was used, with 95% confidence intervals and subgroup differences assessed (P < 0.05 statistically significant).

RESULTS: Seven studies with 380 patients were included. ONSD cutoffs ranged from 4.0 mm to 5.29 mm across studies. For the 20 mmHg cutoff (n = 369), sensitivity was 91.6% [95% CI, 83.2-96.0] and specificity was 71.9% [95% CI, 65.4-77.6]. For the 15 mmHg cutoff (n = 304), sensitivity was 89.3% [95% CI, 83.9-93.1] and specificity was 76.2% [95% CI, 68.0-82.8]. Sensitivity differences by age were statistically significant at 20 mmHg (P = 0.03), with 245 patients > 1 year (sensitivity, 90.1% [95% CI, 83.3-94.3]) and 124 patients < 1 year (sensitivity, 75.7% [95% CI, 59.5-86.8]).

CONCLUSION: The diagnostic accuracy of ultrasound-measured ONSD in detecting intracranial hypertension was high in pediatric patients, although sensitivity varied with age. These findings highlight the importance of age-stratified analyses to assess ONSD accuracy, particularly in infants.

来源:Pediatr Radiol,查看原文。版权归原作者所有。