3T磁共振血管成像计算未破裂脑动脉瘤计算流体力学指标的准确性
本研究回顾性纳入2012至2018年前瞻性队列中63例患者的86个未破裂脑动脉瘤,均行3T MRA和CTA,比较两者计算流体力学指标。除平均OSI外,MRA与CTA获得的平均/最小WSS、平均/最小WSSG和最大OSI均有显著相关性和一致性,提示3T MRA可部分用于脑动脉瘤计算流体力学分析。
要点
- 3T MRA与CTA计算的除平均OSI外的CFD指标具有良好相关性和一致性。
- 平均OSI在MRA与CTA间的相关性和一致性欠佳。
- MRA与CTA间平均WSS/WSSG差异与动脉瘤角度呈显著负相关。
核心结论
- 除平均OSI外,3T MRA获得的未破裂脑动脉瘤CFD值与CTA结果具有良好的相关性和一致性,表明3T MRA可部分应用于脑动脉瘤的CFD分析。
研究设计与样本
- 回顾性纳入2012至2018年前瞻性队列中63例患者的86个未破裂脑动脉瘤,均行3T MRA和CTA检查。
- 对动脉瘤壁进行CFD分析,获取WSS、WSSG和OSI等指标,并比较MRA与CTA计算值。
诊断标准与关键数值
- MRA与CTA间平均/最小WSS、平均/最小WSSG和最大OSI的相关系数为0.60–0.79,组内相关系数为0.62–0.79。
- 平均OSI的相关系数为0.48,组内相关系数为0.31。
- 多变量回归分析显示MRA与CTA间平均WSS/WSSG差异与动脉瘤角度呈显著负相关。
临床应用与阅片要点
- 除平均OSI外,3T MRA计算的CFD指标与CTA具有良好相关性和一致性,可部分用于脑动脉瘤CFD分析。
- 平均OSI在MRA与CTA间相关性和一致性欠佳,解读时需注意。
- MRA与CTA间平均WSS/WSSG差异与动脉瘤角度相关,提示动脉瘤角度可能影响两者一致性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Computational fluid dynamics (CFD) analysis has been applied to predict the rupture of cerebral aneurysms, and results suggest that wall shear stress (WSS) and related metrics can be imaging markers for the risk of rupture. Computed tomography angiography (CTA) is commonly used as source images for CFD analyses. However, it remains unknown whether less-invasive magnetic resonance angiography (MRA) can be used as a substitute for CTA. Hence, we investigated if CFD metrics calculated from MRA were comparable to those calculated from CTA in cerebral aneurysms. METHODS: Sixty-three patients with 86 unruptured aneurysms who underwent MRA at 3T and CTA were retrospectively enrolled between 2012 and 2018 from a prospective cohort study. We performed CFD analyses to obtain indices including the WSS, WSS gradient (WSSG), and oscillatory shear index (OSI) of aneurysmal walls and compared these values between MRA and CTA. RESULTS: Statistically significant correlations and agreements were observed between MRA and CTA for the mean/minimum WSS, mean/minimum WSSG, and maximum OSI values (correlation coefficient = 0.60–0.79, intraclass correlation coefficient = 0.62–0.79). However, the mean OSI value exhibited suboptimal correlation and agreement (0.48 and 0.31, respectively). Multivariate regression analyses further revealed significant negative correlations between discrepancies in the mean WSS/WSSG between MRA and CTA and the aneurysm angle. CONCLUSION: Except for the mean OSI, CFD values of unruptured cerebral aneurysms obtained from 3T MRA showed good correlations and agreements with those from CTA, indicating that 3T MRA can be partly applied for CFD analyses of cerebral aneurysms.
引用
- Mori F, Saito M, Fujimoto K, et al. Accuracy of computational fluid dynamics indices of unruptured cerebral aneurysms with 3 T magnetic resonance angiography. Neuroradiology. 2025. PMID: 40512379. doi:10.1007/s00234-025-03667-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。