干脑征对孕早期畸形筛查中开放性脊柱裂的预测价值:病例对照研究
前瞻性病例对照研究纳入50例孕早期超声筛查的单胎孕妇,25例为超声正常对照,25例为「干脑征」阳性(脉络丛增大且周围无脑脊液)。病例组脉络丛长度、脉络丛/枕额径及脉络丛/双顶径比值显著高于对照组,双顶径和枕额径显著低于对照组。脉络丛/双顶径和脉络丛/枕额径比值诊断准确率均达100%,干脑征可作为孕早期开放性脊柱裂筛查的超声标志物。
要点
- 干脑征定义为脉络丛增大且周围无脑脊液,孕早期出现时需警惕开放性脊柱裂。
- 病例组脉络丛/双顶径和脉络丛/枕额径比值显著高于正常对照组,双顶径和枕额径显著低于对照组。
- 脉络丛/双顶径和脉络丛/枕额径比值诊断准确率均达100%,脉络丛/双顶径 cutoff ≥0.65 为可靠指标。
核心结论
- 干脑征可作为孕早期开放性脊柱裂筛查的超声标志物,采用脉络丛/双顶径和脉络丛/枕额径比值进行早期筛查。
研究设计与样本
- 前瞻性病例对照研究,纳入50例孕早期超声筛查的单胎孕妇(年龄18-40岁),25例超声正常对照与25例干脑征阳性病例等量分组,以孕中晚期超声所见确认开放性脊柱裂诊断。
关键影像表现/征象
- 干脑征表现为脉络丛增大且周围无脑脊液。
- 病例组脉络丛长度、脉络丛/枕额径及脉络丛/双顶径比值均显著高于对照组(p=0.001)。
- 病例组双顶径和枕额径显著低于对照组(p=0.001)。
诊断标准与关键数值
- 脉络丛/双顶径和脉络丛/枕额径比值诊断准确率均达100%,敏感度和特异度均处于最佳水平。
- 脉络丛/双顶径 cutoff ≥0.65 为开放性脊柱裂的可靠标志物(p < 0.001)。
- 平均双顶径 cutoff ≤20.5 mm 为开放性脊柱裂的可靠标志物(p < 0.001)。
临床应用与阅片要点
- 孕早期畸形筛查时若发现脉络丛增大且周围无脑脊液(干脑征),应测量脉络丛/双顶径和脉络丛/枕额径比值。
- 脉络丛/双顶径 ≥0.65 或双顶径 ≤20.5 mm 时,原文提示为开放性脊柱裂的可靠标志物。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Spina bifida is a common neural tube defect resulting from incomplete closure of the spinal column, with early detection crucial for prenatal management. This work aimed to assess the diagnostic utility of the dry brain sign in first-trimester sonographic screening for open spina bifida (OSB).
MATERIALS AND METHODS: This prospective case-control study included 50 pregnant women (aged 18-40 years) who underwent first-trimester ultrasound screening for singleton pregnancies. Participants were divided into two equal groups: 25 controls with normal ultrasound findings and 25 cases exhibiting a positive "dry brain sign," defined by enlarged choroid plexuses without surrounding cerebrospinal fluid. Second and third-trimester ultrasound findings were used to confirm OSB diagnoses.
RESULTS: The case group exhibited significantly higher mean choroid plexus (CP) length, CP to occipitofrontal diameter (CP/OFD), and CP to biparietal diameter (CP/BPD) ratio (p= 0.001). BPD and OFD were significantly lower in the case group compared with the controls (p= 0.001). CP/BPD and CP/OFD demonstrated the highest diagnostic accuracy (100%) with optimal sensitivity and specificity. CP/BPD (cutoff ≥0.65, p < 0.001) and mean BPD (cutoff ≤20.5 mm, p < 0.001) were reliable markers for OSB.
CONCLUSION: Dry brain sign could be used as sonographic markers for early screening in the first trimester for OSB by using mean CP/BPD ratio and mean CP/OFD ratios.
引用
- El Din Abd El Fatah El Emam HK, Ali Hassan HGEM, El Feky SM, et al. The Predictive Value of Dry Brain Sign for Open Spina Bifida at First Trimester Anomaly Scan: A Case-Control study. Acad Radiol. 2025. PMID: 40533300. doi:10.1016/j.acra.2025.04.069
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。