文献速递神经头颈MR

基于增强T1加权成像的影像组学鉴别原发性中枢神经系统淋巴瘤与单发脑转移瘤:一项回顾性机器学习研究

Radiomics-Based Differentiation of Primary Central Nervous System Lymphoma and Solitary Brain Metastasis Using Contrast-Enhanced T1-Weighted Imaging: A Retrospective Machine Learning Study.
PubMed 文献 · Acad Radiol · 2025-06-04

回顾性纳入2014年1月至2024年12月病理确诊的324例患者(PCNSL 115例、SBM 209例),于增强T1WI勾画肿瘤并提取1561个影像组学特征,经LASSO筛选出23个特征训练多种机器学习分类器;独立测试中SVMRBF分类器AUC最高为0.9310、准确率0.8780,所选模型标准化净获益均超过0.6。

要点

  • 增强T1WI影像组学模型可辅助鉴别PCNSL与SBM,独立测试中SVMRBF分类器AUC达0.9310。
  • LASSO回归从1561个特征中筛选出23个特征用于建模。
  • 10折交叉验证中ANN分类器AUC最高为0.9305,SVMPOLY为0.9226。

核心结论

  • 基于增强T1WI的影像组学模型在准确鉴别PCNSL与SBM方面显示出令人鼓舞的潜力,SVMRBF分类器在全部测试分类器中诊断效能最高,提示其在该鉴别诊断中具有潜在临床价值。

研究设计与样本

  • 回顾性研究,纳入2014年1月至2024年12月病理确诊的324例患者(PCNSL 115例、SBM 209例),于增强T1WI手动勾画肿瘤区域并提取1561个影像组学特征。

诊断标准与关键数值

  • 经LASSO回归筛选出23个特征;10折交叉验证中ANN分类器AUC最高为0.9305,SVMPOLY分类器为0.9226;独立测试中SVMRBF分类器AUC为0.9310、准确率最高为0.8780;20个分类器中15个AUC超过0.9。

临床应用与阅片要点

  • 研究采用决策曲线分析并以0.5风险阈值平衡假阳性与假阴性,所选模型(SVMRBF、SVMPOLY、ELDA、ANN、RF、GBRUSB)标准化净获益均超过0.6。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To develop and evaluate radiomics-based models using contrast-enhanced T1-weighted imaging (CE-T1WI) for the non-invasive differentiation of primary central nervous system lymphoma (PCNSL) and solitary brain metastasis (SBM), aiming to improve diagnostic accuracy and support clinical decision-making.

METHODS: This retrospective study included a cohort of 324 patients pathologically diagnosed with PCNSL (n=115) or SBM (n=209) between January 2014 and December 2024. Tumor regions were manually segmented on CE-T1WI, and a comprehensive set of 1561 radiomic features was extracted. To identify the most important features, a two-step approach for feature selection was utilized, which involved the use of least absolute shrinkage and selection operator (LASSO) regression. Multiple machine learning classifiers were trained and validated to assess diagnostic performance. Model performance was evaluated using area under the curve (AUC), accuracy, sensitivity, and specificity. The effectiveness of the radiomics-based models was further assessed using decision curve analysis, which incorporated a risk threshold of 0.5 to balance both false positives and false negatives.

RESULTS: 23 features were identified through LASSO regression. All classifiers demonstrated robust performance in terms of area under the curve (AUC) and accuracy, with 15 out of 20 classifiers achieving AUC values exceeding 0.9. In the 10-fold cross-validation, the artificial neural network (ANN) classifier achieved the highest AUC of 0.9305, followed by the support vector machine with polynomial kernels (SVMPOLY) classifier at 0.9226. Notably, the independent test revealed that the support vector machine with radial basis function (SVMRBF) classifier performed best, with an AUC of 0.9310 and the highest accuracy of 0.8780. The selected models-SVMRBF, SVMPOLY, ensemble learning with LDA (ELDA), ANN, random forest (RF), and grading boost with random undersampling boosting (GBRUSB)-all showed significant clinical utility, with their standardized net benefits (sNBs) surpassing 0.6. These results underline the potential of the radiomics-based models in reliably distinguishing PCNSL from SBM.

CONCLUSION: The application of radiomic-driven models based on CE-T1WI has demonstrated encouraging potential for accurately distinguishing between PCNSL and SBM. The SVMRBF classifier showed the greatest diagnostic efficacy of all the classifiers tested, indicating its potential clinical utility in differential diagnosis.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Xia X, Qiu J, Tan Q, et al. Radiomics-Based Differentiation of Primary Central Nervous System Lymphoma and Solitary Brain Metastasis Using Contrast-Enhanced T1-Weighted Imaging: A Retrospective Machine Learning Study. Acad Radiol. 2025. PMID: 40467374. doi:10.1016/j.acra.2025.05.043

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。