定量脑合成磁共振成像对阻塞性睡眠呼吸暂停患者的诊断价值
研究纳入50例未治疗初诊阻塞性睡眠呼吸暂停(OSA)患者与36例非OSA患者,采用3.0T磁共振行脑合成MRI(SyMRI)扫描,比较灰白质弛豫值及质子密度值差异并分析其与呼吸暂停低通气指数的相关性。OSA组灰白质T2值显著降低,灰质T1及质子密度值轻度降低;白质T2值诊断AUC最高(0.74),敏感度92.0%、特异度52.0%;灰质T1与T2值AUC均为0.69。作者认为SyMRI定量参数对成人OSA患者有重要临床价值,尤其T2弛豫值有助于脑微结构损伤的早期诊断。
要点
- OSA组灰质与白质T2值较正常组显著降低(P<0.05)。
- 白质T2值诊断OSA的AUC最高(0.74),敏感度92.0%,特异度52.0%。
- 灰质T1值与AHI正相关,灰白质T2值与AHI负相关(P<0.05)。
核心结论
- SyMRI定量参数对成人OSA患者有显著临床价值,尤其T2弛豫值有助于脑微结构损伤的早期诊断。
研究设计与样本
- 研究纳入50例未治疗初诊OSA患者为OSA组、36例非OSA患者为正常组,均使用GE SIGNA Architect 3.0T磁共振行颅脑扫描,比较两组灰质弛豫值、白质弛豫值及质子密度值的差异,并分析上述参数与呼吸暂停低通气指数的相关性。
关键影像表现/征象
- OSA组灰质与白质T2值较正常组显著降低,差异有统计学意义(P<0.05)。
- OSA组灰质T1值与质子密度值较正常组轻度降低,差异有统计学意义(P<0.05)。
诊断标准与关键数值
- 白质T2值诊断OSA的AUC为0.74,敏感度92.0%,特异度52.0%。
- 灰质T1值与灰质T2值的AUC均为0.69,灰质T1值特异度75.0%,灰质T2值敏感度92.0%。
- 灰质T1值与AHI呈正相关,灰质T2值与白质T2值均与AHI呈负相关(P<0.05)。
临床应用与阅片要点
- 作者认为SyMRI定量参数对成人OSA患者有显著临床价值,尤其T2弛豫值有助于脑微结构损伤的早期诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: Investigating the diagnostic value of quantitative brain synthetic magnetic resonance imaging (SyMRI) in adult patients with obstructive sleep apnoea (OSA) and brain microstructural injury.
MATERIALS AND METHODS: Fifty untreated OSA patients at initial diagnosis who were diagnosed were collected as the OSA group, with 36 non-OSA patients as the normal group. Afterwards, all subjects underwent cranial scans using GE SIGNA Architect 3.0T magnetic resonance imaging. Meanwhile, the differences in grey matter relaxation values, white matter relaxation values, and proton density (PD) values between the 2 groups were compared, followed by an analysis of the correlation between the above parameters and apnoea-hypopnoea index (AHI).
RESULTS: Compared with the normal group, T2 values of grey and white matter were significantly decreased, and T1 and PD values of grey matter were slightly decreased in the OSA group, with significant differences (P<005). In the meantime, receiver operating characteristic curves suggested the highest area under the curve (AUC) (0.74) and a high sensitivity (92.0%) of T2 values of white matter, along with a low specificity (52.0%). Additionally, the T1 and T2 values of grey matter shared the same AUC (0.69), which exhibited high specificity (75.0%) and high sensitivity (92.0%), respectively. Furthermore, Spearman correlation analysis indicated that T1 values of grey matter were positively correlated with AHI, while T2 values of grey and white matter were negatively correlated with AHI (P<0.05).
CONCLUSION: SyMRI quantitative imaging parameters are of significant clinical value for adult OSA patients, especially T2 relaxation values, which are beneficial for the early diagnosis of brain microstructural injury.