指南与共识技术与安全

针对性干预措施对放射科医生附加影像检查建议的累积效应

Cumulative Effect of Targeted Interventions on Radiologist Recommendations for Additional Imaging.
指南 / 共识 · Radiology · 2025-01-01

这项回顾性队列研究分析了2015年1月至2022年12月两家三级医院共7502521份放射学报告,评估多项技术辅助质量改进干预对附加影像检查建议(RAI)的影响。研究点RAI率从10%降至5.6%(降低44%),对照点无变化;研究点建议可操作性提高7.6倍,可操作建议的解决率也高于对照点。

要点

  • 研究点RAI率从10%降至5.6%(降低44%),对照点维持在约11%不变
  • 研究点建议可操作性从5.6%升至42.3%(提高7.6倍),对照点无变化
  • 研究点可操作RAI解决率84.7%,高于对照点的59.6%

核心结论

  • 多方面的技术辅助干预可改善RAI的发生率、可操作性和解决率。

研究设计与样本

  • 回顾性队列研究,纳入2015年1月至2022年12月两家三级医院共7502521份放射学报告(1323459例患者),研究点3608977份报告(660051例患者),对照点3893544份报告(690115例患者);研究点实施放射科医生教育、RAI电子追踪沟通工具和绩效报告等系列质量改进干预,对照点未实施;采用线性回归比较RAI率趋势,混合效应逻辑回归评估干预影响,Fisher精确检验比较可操作性和解决率,P值用Bonferroni法校正。

诊断标准与关键数值

  • 研究点RAI率从10%(8202/81586)降至5.6%(8972/159599),降低44%;对照点从10.9%(8757/80030)至11%(16978/153711)保持不变;回归系数-0.09(95%CI:-0.1,-0.09),P<.001。
  • 研究点RAI率随每项 successive 干预下降(P<.001),回归系数从初始干预的-0.12(95%CI:-0.14,-0.10)逐步降至最终干预的-0.81(95%CI:-0.83,-0.78)。
  • 研究点建议可操作性从5.6%(19/340)升至42.3%(144/340),提高7.6倍,P<.001;对照点从15.0%(51/340)至13.8%(47/340),P=.73。
  • 研究点可操作RAI解决率84.7%(122/144),高于对照点的59.6%(28/47),P<.001。

临床应用与阅片要点

  • 原文结论为多方面干预可改善RAI的发生率、可操作性和解决率,未给出具体阅片操作建议。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Ambiguous or unnecessary radiologist recommendations for additional imaging (RAIs) can lead to excessive imaging use and diagnostic errors. Purpose To determine the cumulative impacts of multifaceted technology-enabled interventions aimed at optimizing RAI on RAI rate, actionability, and resolution over an 8-year period. Materials and Methods In this retrospective cohort study, conducted from January 2015 to December 2022, radiology reports from two tertiary hospitals (study site and control site) were analyzed. A series of quality improvement interventions, including radiologist education, electronic communication tools for tracking RAIs, and performance reports, were implemented at the study site but not at the control site. The RAI rate trend over time was compared between the sites using linear regression. Mixed-effects logistic regression was performed to assess the intervention impact on the RAI rate. RAI actionability and resolution were compared between the sites using the Fisher exact test. P values were corrected using the Bonferroni method. Results Among 7 502 521 total radiology reports (1 323 459 patients) (study site, 3 608 977 reports and 660 051 patients; control site, 3 893 544 reports and 690 115 patients), the RAI rate of the study site decreased by 44%, from 10% (8202 of 81 586) to 5.6% (8972 of 159 599), but remained unchanged at the control site, at 10.9% (8757 of 80 030) vs 11% (16 978 of 153 711) (regression coefficient, -0.09; 95% CI: -0.1, -0.09; P < .001). RAI rates declined with each successive intervention at the study site (P < .001), with regression coefficients decreasing progressively from -0.12 (95% CI: -0.14, -0.10) for the initial intervention to -0.81 (95% CI: -0.83, -0.78) for the final intervention. Recommendation actionability at the study site increased 7.6-fold (from 5.6% [19 of 340] to 42.3% [144 of 340]; P < .001) but remained unchanged at the control site (from 15.0% [51 of 340] to 13.8% [47 of 340]; P = .73). Actionable RAIs were more frequently resolved at the study site than at the control site (84.7% [122 of 144] vs 59.6% [28 of 47]; P < .001). Conclusion Multifaceted interventions to optimize RAI improved the rate, actionability, and resolution of RAI. © RSNA, 2025 Supplemental material is available for this article. See also the editorial by Russell in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Abbasi N, Kapoor N, Lacson R, et al. Cumulative Effect of Targeted Interventions on Radiologist Recommendations for Additional Imaging. Radiology. 2025. PMID: 40459413. doi:10.1148/radiol.243750

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。