文献速递腹部技术与安全CT

在宽范围体重指数患者的100-kVp CT小肠造影中使用深度学习图像重建提高图像质量和诊断性能

Improving image quality and diagnostic performance using deep learning image reconstruction in 100-kVp CT enterography for patients with wide-range body mass index.
PubMed 文献 · Eur J Radiol · 2025-05-14

纳入84例宽范围BMI患者行100-kVp双期CTE,比较FBP、ASiR-V 30%、ASiR-V 60%及DLIR-L/M/H的图像质量与肠病损检出。DLIR降低噪声并改善CNR和SNR,DLIR-M诊断信心优于ASiR-V 60%,两名初级读者对炎性病损敏感度数值较高但未达统计学显著。

要点

  • DLIR-H噪声最低,DLIR-M与DLIR-H整体图像质量相当且优于ASiR-V 60%。
  • DLIR相对CNR增量与BMI呈正线性相关(r 0.307–0.506,均p≤0.005)。
  • DLIR-M诊断信心优于ASiR-V 60%(三名读者均p≤0.018)。

核心结论

  • DLIR可有效降低100-kVp双期CTE宽范围BMI患者的噪声并改善图像质量,DLIR-M在图像质量和诊断信心方面表现更优,并可能在提高初级读者肠道炎性病损检出方面具有潜在价值,尚需进一步研究。

研究设计与样本

  • 共纳入84例接受100-kVp双期CTE的患者,图像分别用FBP、ASiR-V 30%、ASiR-V 60%及DLIR-L、DLIR-M、DLIR-H重建;采用重复测量方差分析(Bonferroni校正)或Friedman检验比较CT值、SD、SNR和CNR,Pearson相关系数分析相对CNR增量与BMI的相关性,McNemar检验比较DLIR-M与ASiR-V 60%的肠病损检出。

关键影像表现/征象

  • SD从FBP、ASiR-V 30%、DLIR-L、ASiR-V 60%、DLIR-M到DLIR-H依次降低,CNR和SNR相应改善(均p<0.001)。
  • DLIR相对CNR增量与BMI呈显著正线性相关(r 0.307–0.506,均p≤0.005)。
  • 整体图像质量评分排序为FBP<ASiR-V 30%<ASiR-V 60%≈DLIR-L<DLIR-M≈DLIR-H。

诊断标准与关键数值

  • 两名初级读者对炎性病损的敏感度:读者1 DLIR-M 0.700(95%CI 0.354–0.919)vs ASiR-V 60% 0.300(95%CI 0.081–0.646),未达统计学显著。
  • 读者2 DLIR-M 0.700(95%CI 0.354–0.919)vs ASiR-V 60% 0.500(95%CI 0.201–0.799),未达统计学显著。
  • DLIR-M诊断信心优于ASiR-V 60%,三名读者均p≤0.018。

临床应用与阅片要点

  • 在100-kVp双期CTE宽范围BMI患者中,DLIR-M可提供优于ASiR-V 60%的诊断信心和整体图像质量。
  • DLIR相对CNR增量随BMI增高而增大,提示高BMI患者可能从DLIR获益更明显。
  • 初级读者对肠道炎性病损的检出敏感度在DLIR-M图像上数值较高,但未达统计学显著。

局限性

  • DLIR-M在提高初级读者肠道炎性病损检出方面的潜在价值尚需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the clinical value of the deep learning image reconstruction (DLIR) algorithm compared with conventional adaptive statistical iterative reconstruction-Veo (ASiR-V) in image quality, diagnostic confidence, and intestinal lesion detection in 100-kVp CT enterography (CTE) for patients with wide-range body mass index (BMI).

METHODS: A total of 84 patients underwent 100-kVp dual-phase CTE were included. Images were reconstructed using filtered back projection (FBP), ASiR-V 30 %, ASiR-V 60 %, and DLIR with low, medium, and high levels (DLIR-L, DLIR-M, and DLIR-H). The CT value, standard deviation (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of small and large intestines were compared using repeated measures analysis of variance with the Bonferroni correction or Friedman test. The correlation between relative CNR increment and BMI was analyzed using Pearson's correlation coefficient. The overall image quality and diagnostic confidence scores were evaluated. Additionally, lesion detection of intestinal disease was conducted by three readers with different experience and compared between DLIR-M and ASiR-V 60 % images using McNemar's test.

RESULTS: SD decreased sequentially from FBP, ASiR-V 30 %, DLIR-L, ASiR-V 60 %, DLIR-M, to DLIR-H, which corresponded with improvements in CNR and SNR (all p < 0.001). The relative CNR increment of DLIR exhibited a significantly positive linear correlation with BMI (r:0.307-0.506, all p ≤ 0.005). For overall image quality scores, the ranking was: FBP < ASiR-V 30 % < ASiR-V 60 % ≈DLIR-L < DLIR-M ≈ DLIR-H. DLIR-M outperformed ASiR-V 60 % in diagnostic confidence (p ≤ 0.018 for all three readers). In lesion detection, for the two junior readers, DLIR-M exhibited higher sensitivity for inflammatory lesions compared to ASiR-V 60 % (0.700 (95 % confidence interval [95 % CI]: 0.354-0.919) vs. 0.300 (95 % CI: 0.081-0.646) for reader 1 and 0.700 (95 %CI: 0.354-0.919) vs. 0.500 (95 % CI: 0.201-0.799) for reader 2), though no statistical significance was reached.

CONCLUSION: DLIR effectively reduces noise and improves image quality in 100-kVp dual-phase CTE for wide-range BMIs. DLIR-M exhibits superior performance in image quality and diagnostic confidence, also provide potential value in improving intestinal inflammatory lesion detection in junior readers and sheds lights on benefiting clinical decision making, which needs further investigation.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Luo Y, Tang Y, Chen S, et al. Improving image quality and diagnostic performance using deep learning image reconstruction in 100-kVp CT enterography for patients with wide-range body mass index. Eur J Radiol. 2025. PMID: 40398003. doi:10.1016/j.ejrad.2025.112167

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。