文献速递儿科影像胸部外周血管CT

深度学习图像重建算法在儿童肺隔离症四低CT血管成像中维持高图像质量与诊断准确性的病例对照研究

Deep Learning Image Reconstruction (DLIR) Algorithm to Maintain High Image Quality and Diagnostic Accuracy in Quadruple-low CT Angiography of Children with Pulmonary Sequestration: A Case Control Study.
PubMed 文献 · Acad Radiol · 2025-05-22

本研究纳入53例疑似肺隔离症患儿行四低CTA(低管电压、低辐射、低对比剂、低注射流率)并使用深度学习图像重建,与53例常规剂量CTA使用自适应统计迭代重建V对比;四低CTA辐射剂量降低51%、对比剂剂量降低47%、注射流率降低44%、注射压力降低44%(均p<0.05),两组诊断肺隔离症的敏感度和特异度均达100%,四低CTA的对比噪声比降低27%(p<0.05)但边缘上升距离相似(p>0.05),可显示直径0.8 mm的小动脉。

要点

  • 四低CTA联合深度学习图像重建在儿童肺隔离症诊断中敏感度和特异度均达100%。
  • 四低CTA较常规CTA辐射剂量降低51%、对比剂剂量降低47%、注射流率降低44%、注射压力降低44%。
  • 四低CTA对比噪声比降低27%但边缘上升距离相似,可显示直径0.8 mm小动脉。

核心结论

  • 深度学习图像重建支持儿童肺隔离症四低CTA实现辐射和对比剂剂量显著降低,同时维持图像质量、小动脉显示和高诊断准确度。

关键影像表现/征象

  • 四低CTA较常规CTA辐射剂量降低51%、对比剂剂量降低47%、注射流率降低44%、注射压力降低44%(均p<0.05)。
  • 四低CTA的对比噪声比较常规CTA降低27%(p<0.05),边缘上升距离与常规CTA相似(p>0.05)。
  • 四低CTA可显示直径0.8 mm的小动脉。
  • 两组主观图像质量和动脉显示均满意,主观评分采用5分制(5分为优,3分为可接受)。

诊断标准与关键数值

  • 四低CTA和常规CTA诊断肺隔离症的敏感度和特异度均达100%。
  • 主观整体图像质量和动脉显示采用5分制评估(5分优,3分可接受)。

临床应用与阅片要点

  • 儿童肺隔离症CTA可采用四低方案(低管电压、低辐射、低对比剂、低注射流率)联合深度学习图像重建,在显著降低辐射和对比剂剂量的同时维持诊断准确度。
  • 阅片时注意四低CTA对比噪声比较常规CTA降低27%,但边缘上升距离相似,不影响小动脉(直径0.8 mm)的显示。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: CT angiography (CTA) is a commonly used clinical examination to detect abnormal arteries and diagnose pulmonary sequestration (PS). Reducing the radiation dose, contrast medium dosage, and injection pressure in CTA, especially in children, has always been an important research topic, but few research is proven by pathology. The current study aimed to evaluate the diagnostic accuracy for children with PS in a quadruple-low CTA (4L-CTA: low tube voltage, radiation, contrast medium, and injection flow rate) using deep learning image reconstruction (DLIR) in comparison with routine protocol CTA with adaptive statistical iterative reconstruction-V (ASIR-V) MATERIALS AND METHODS: 53 patients (1.50±1.36years) suspected with PS were enrolled to undergo chest 4L-CTA using 70kVp tube voltage with radiation dose or 0.90 mGy in volumetric CT dose index (CTDIvol) and contrast medium dose of 0.8 ml/kg injected in 16 s. Images were reconstructed using DLIR. Another 53 patients (1.25±1.02years) with a routine dose protocol was used for comparison, and images were reconstructed with ASIR-V. The contrast-to-noise ratio (CNR) and edge-rise distance (ERD) of the aorta were calculated. The subjective overall image quality and artery visualization were evaluated using a 5-point scale (5, excellent; 3, acceptable). All patients underwent surgery after CT, the sensitivity and specificity for diagnosing PS were calculated.

RESULTS: 4L-CTA reduced radiation dose by 51%, contrast dose by 47%, injection flow rate by 44% and injection pressure by 44% compared to the routine CTA (all p<0.05). Both groups had satisfactory subjective image quality and achieved 100% in both sensitivity and specificity for diagnosing PS. 4L-CTA had a reduced CNR (by 27%, p<0.05) but similar ERD, which reflects the image spatial resolution (p>0.05) compared to the routine CTA. 4L-CTA revealed small arteries with a diameter of 0.8 mm.

CONCLUSION: DLIR ensures the realization of 4L-CTA in children with PS for significant radiation and contrast dose reduction, while maintaining image quality, visualization of small arteries, and high diagnostic accuracy.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Li H, Zhang Y, Hua S, et al. Deep Learning Image Reconstruction (DLIR) Algorithm to Maintain High Image Quality and Diagnostic Accuracy in Quadruple-low CT Angiography of Children with Pulmonary Sequestration: A Case Control Study. Acad Radiol. 2025. PMID: 40410108. doi:10.1016/j.acra.2025.05.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。