7特斯拉双回波稳态序列对膝关节周围神经及神经束的磁共振成像
前瞻性纳入32名健康参与者,在7T MRI上比较质子密度涡轮自旋回波脂肪抑制(PD-TSE FS)、三维双回波稳态(3D-DESS)及更高平面分辨率DESS(DESSHR)序列对膝关节周围神经及神经束的显示能力。DESSHR在神经与脂肪、肌肉的对比噪声比及腓总神经、胫神经、隐神经可视化方面表现更优,而3D-DESS显示腓总神经分支更佳且搏动伪影更少。
要点
- DESSHR序列在7T下对腓总神经、胫神经及隐神经的整体可视化优于PD-TSE FS和3D-DESS。
- 3D-DESS显示腓总神经分支优于其他序列,且搏动伪影最少。
- DESSHR的胫神经信噪比低于PD-TSE FS和3D-DESS,但腓总神经信噪比在三序列间无显著差异。
核心结论
- 7T MRI的DESS序列可提升膝关节周围外周神经及神经束结构的可视化。
研究设计与样本
- 前瞻性纳入32名健康参与者(平均年龄39±14岁,20名女性),行7T膝关节MRI,采集PD-TSE FS、3D-DESS和DESSHR序列,由两名读者定量测量信噪比和对比噪声比,五名放射科医生定性评估图像质量、搏动伪影及神经可视化。
诊断标准与关键数值
- 胫神经信噪比在DESSHR序列低于PD-TSE FS(P<0.001)和3D-DESS(P=0.024)序列。
- 腓总神经信噪比在三序列间无显著差异。
- DESSHR的胫神经或腓总神经-脂肪及腓总神经-肌肉对比噪声比优于PD-TSE FS和3D-DESS(P≤0.016)。
- DESSHR和PD-TSE FS的胫神经及腓总神经-血管对比噪声比高于3D-DESS(P≤0.001)。
- 定性评估显示3D-DESS搏动伪影少于DESSHR和PD-TSE FS(P<0.001),DESSHR伪影少于PD-TSE FS(P=0.035)。
临床应用与阅片要点
- DESSHR序列在显示腓总神经、胫神经和隐神经方面优于其他序列(P<0.001)。
- 3D-DESS序列在显示腓总神经分支方面优于其他序列(P≤0.042)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the applicability of the double echo steady state (DESS) sequence at 7 tesla (7T) for high-resolution imaging of the peripheral nerves and fascicles of the knee.
MATERIALS AND METHODS: We prospectively included 32 healthy participants (mean age 39 ± 14 years, 20 females). The patients underwent 7T magnetic resonance imaging (MRI) of the knee using proton density turbo spin-echo fat suppression (PD-TSE FS), three-dimensional DESS (3D-DESS), and higher in-plane resolution DESS (DESSHR) sequences. The signal-to-noise ratios (SNRs) of the peroneal nerve (PN) and tibial nerve (TN) and contrast-to-noise ratios (CNRs) between the nerves and adjacent fat, vessels, and muscles were quantitatively measured by two readers and averaged. Five radiologists qualitatively assessed the overall image quality, pulsatile flow artifacts, and visualization of the PN and its branches, the TN, and the saphenous nerve (SN) using a five-point Likert-type scale, with the results averaged. The results of the three image sequences were compared.
RESULTS: The SNR for the TNs in the DESSHR sequence were lower than those in the PD-TSE FS (P < 0.001) and 3D-DESS (P = 0.024) sequences, whereas the SNR for the PNs did not differ significantly across the three sequences. The DESSHR sequence exhibited superior TN- or PN-to-fat and PN-to-muscle CNR values when compared with the PD-TSE FS and 3D-DESS sequences (P ≤ 0.016). The TN- and PN-to-vessel CNR values in the DESSHR and PD-TSE FS sequences were higher than those in the 3D-DESS sequence (P ≤ 0.001). Qualitative assessments revealed fewer pulsatile artifacts in 3D-DESS than in DESSHR and PD-TSE FS (P < 0.001), with DESSHR exhibiting fewer artifacts than PD-TSE FS (P = 0.035). DESSHR excelled in visualizing the common PN, TN, and SN when compared with other sequences (P < 0.001), whereas 3D-DESS provided superior visualization of PN branches when compared with other sequences (P ≤ 0.042).
CONCLUSION: The DESS sequence at 7T MRI enhances visualization of peripheral nerves and fascicular structures around the knee.
引用
- Chen P, Zhen Z, Li J, et al. Magnetic Resonance Imaging of the Peripheral Nerves and Fascicles of the Knee Using Double Echo Steady State Sequence at 7 Tesla. Korean J Radiol. 2025. PMID: 40432262. doi:10.3348/kjr.2024.0912
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。