基于超声图像的瘤内及瘤周影像组学用于术前鉴别滤泡性甲状腺腺瘤、癌及恶性潜能未定的滤泡性肿瘤
本研究回顾性纳入2018年1月至2023年12月774例甲状腺切除术后超声图像(FTA 429例、FTC 158例、FT-UMP 187例),构建瘤内及瘤周影像组学联合临床特征的模型。临床特征联合瘤内及5%瘤周影像组学特征在各任务中表现最佳(测试集任务1 AUC 0.93、任务2 AUC 0.90,诊断准确率79.9%)。DeLong检验显示所有瘤周影像组学均显著提升瘤内影像组学及临床特征的性能(p<0.04)。
要点
- 临床特征联合瘤内及5%瘤周影像组学特征在鉴别FTA、FTC与FT-UMP中表现最佳。
- 测试集任务1(FTA与其他类型)AUC 0.93,任务2(FTC与FT-UMP)AUC 0.90,诊断准确率79.9%。
- 5%瘤周区域表现最佳,可能提示潜在肿瘤侵犯区域,需进一步研究。
核心结论
- 基于超声的瘤内及瘤周影像组学可显著提升FTA、FTC与FT-UMP的术前诊断准确率,从而改善治疗策略与患者结局。
研究设计与样本
- 回顾性研究,纳入2018年1月至2023年12月774例甲状腺切除术后超声图像,FTA 429例、FTC 158例、FT-UMP 187例;采用segment-anything模型结合提示学习检测视野并约束瘤周扩展边界;瘤周区域以5%递增从5%扩展至30%;采用逐步分类策略处理三项任务。
诊断标准与关键数值
- 临床特征联合瘤内及5%瘤周影像组学特征表现最佳:测试集任务1(FTA与其他类型)AUC 0.93,任务2(FTC与FT-UMP)AUC 0.90,诊断准确率79.9%。
临床应用与阅片要点
- 作者认为5%瘤周区域可能提示潜在肿瘤侵犯区域,需进一步研究;原文未据此给出其他临床推荐。
局限性
- 5%瘤周区域表现最佳,但并非所有结果均显著(p=0.01-0.91)。
- 5%瘤周区域可能提示潜在肿瘤侵犯区域,需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Differentiating between follicular thyroid adenoma (FTA), carcinoma (FTC), and follicular tumor with uncertain malignant potential (FT-UMP) remains challenging due to their overlapping ultrasound characteristics. This retrospective study aimed to enhance preoperative diagnostic accuracy by utilizing intra- and peritumoral radiomics based on ultrasound images.
METHODS: We collected post-thyroidectomy ultrasound images from 774 patients diagnosed with FTA (n = 429), FTC (n = 158), or FT-UMP (n = 187) between January 2018 and December 2023. Six peritumoral regions were expanded by 5%-30% in 5% increments, with the segment-anything model utilizing prompt learning to detect the field of view and constrain the expanded boundaries. A stepwise classification strategy addressing three tasks was implemented: distinguishing FTA from the other types (task 1), differentiating FTC from FT-UMP (task 2), and classifying all three tumors. Diagnostic models were developed by combining radiomic features from tumor and peritumoral regions with clinical characteristics.
RESULTS: Clinical characteristics combined with intratumoral and 5% peritumoral radiomic features performed best across all tasks (Test set: area under the curves, 0.93 for task 1 and 0.90 for task 2; diagnostic accuracy, 79.9%). The DeLong test indicated that all peritumoral radiomics significantly improved intratumoral radiomics performance and clinical characteristics (p < 0.04). The 5% peritumoral regions showed the best performance, though not all results were significant (p = 0.01-0.91).
CONCLUSION: Ultrasound-based intratumoral and peritumoral radiomics can significantly enhance preoperative diagnostic accuracy for FTA, FTC, and FT-UMP, leading to improved treatment strategies and patient outcomes. Furthermore, the 5% peritumoral area may indicate regions of potential tumor invasion requiring further investigation.
引用
- Fu Y, Mei F, Shi L, et al. Intra- and Peritumoral Radiomics Based on Ultrasound Images for Preoperative Differentiation of Follicular Thyroid Adenoma, Carcinoma, and Follicular Tumor With Uncertain Malignant Potential. Ultrasound Med Biol. 2025. PMID: 40350346. doi:10.1016/j.ultrasmedbio.2025.04.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。