改进乳腺X线摄影中小簇微钙化的评估:实施真空辅助切除联合「腔缘修整」技术
研究纳入72例≤15 mm单簇微钙化(BI-RADS>3)患者,在数字乳腺断层摄影引导下行真空辅助切除并采用「腔缘修整」技术,分别取12个焦点样本和12个清洁样本行组织病理学评估。清洁样本无残留病变者中70%(21/30)后续手术未发现残留或升级;清洁样本阴性者手术恶性检出率1/5(20.0%),阳性者4/5(80.0%),差异有统计学意义(P=0.007)。作者认为该技术对符合影像学和组织学标准的特定患者(如ADH或低级别DCIS)可能是有价值的替代手术切除的选择。
要点
- ≤15 mm单簇微钙化(BI-RADS>3)行DBT引导真空辅助切除时,加做「腔缘修整」可分别评估焦点样本与清洁样本。
- 清洁样本无残留病变者后续手术恶性检出率低:阴性1/5(20.0%)vs 阳性4/5(80.0%),P=0.007。
- 清洁样本无残留病变的阴性预测值为95.24%(95%CI:76.39%-99.20%)。
核心结论
- 在符合影像学和组织学标准的特定患者(如ADH或低级别DCIS)中,DBT引导下真空辅助切除联合「腔缘修整」技术可能是有价值的替代手术切除的选择。
研究设计与样本
- 单中心前瞻性研究?原文未明确研究类型;共纳入72例单簇微钙化(BI-RADS>3且<15 mm)患者,在数字乳腺断层摄影引导下行真空辅助切除,采用「腔缘修整」技术分别取12个焦点样本和12个清洁样本行组织病理学评估,并比较清洁样本状态与后续手术切除结果。
诊断标准与关键数值
- 清洁样本无残留病变的阴性预测值为95.24%(95%CI:76.39%-99.20%);清洁样本阴性者手术恶性检出率1/5(20.0%),阳性者4/5(80.0%),P=0.007。
临床应用与阅片要点
- 作者认为,对于符合影像学和组织学标准的特定患者(如ADH或低级别DCIS),DBT引导下真空辅助切除联合「腔缘修整」技术可能是有价值的替代手术切除的选择。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The purpose of our study is to assess the diagnostic performance and treatment effectiveness of vacuum assisted excision (VAE) under digital breast tomosynthesis (DBT) guidance with "cavity margins shaving" technique to ensure total lesion removal in patients with ≤ 15 mm clusters of microcalcifications.
MATERIALS AND METHODS: Patients with a single cluster of microcalcifications (BI-RADS > 3) < 15 mm who underwent DBT-guided VAE were enrolled. The "cavity margins shaving" technique was used: 12 focus samples (FS) and 12 cleaning samples (CS) were taken and the histopathologic assessment of the FS and CS was performed separately. The presence of residual disease within the CS was assessed. The surgical excision results were compared according to the CS status.
RESULTS: A total of 72 patients were included, with 12 benign (16.7%), 45 B3 (62.5%) and 15 malignant (20.8%) lesions. Among the 13 ductal carcinomas in situ (DCIS) and 17 atypical ductal hyperplasia (ADH) cases without residual disease within the CS (21/30, 70%), in 2 cases residual pathology was detected in the subsequent surgery, without any case of upgrade. Comparing the presence of malignant disease (residual DCIS or upgrade of ADH) at surgical excision according to the CS status, the rates were 1/5 (20.0 %) and 4/5 (80.0 %) respectively for negative and positive CS (P = 0.007). The NPV of the absence of residual lesion in the CS was 95.24 % (95 %CI: 76.39 %-99.20 %).
CONCLUSION: VAE with cavity margins shaving technique could represent a valuable alternative to surgical excision in selected patients (such as those with ADH or low-grade DCIS) who met the radiologic and histologic criteria.
引用
- Rella R, Romanucci G, Belli P, et al. Improved evaluation of patients with small clusters of microcalcifications on mammograms: Implementation of vacuum assisted excision with "cavity margins shaving" technique. Eur J Radiol. 2025. PMID: 40311272. doi:10.1016/j.ejrad.2025.112138
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。