文献速递乳腺MR

用于极密乳腺女性筛查的简化乳腺MRI多阅片者诊断准确性

Multireader Diagnostic Accuracy of Abbreviated Breast MRI for Screening Women with Extremely Dense Breasts.
PubMed 文献 · Radiology · 2025-01-01

该研究为DENSE试验二次分析,7名放射科医师对518例极密乳腺且钼靶阴性女性的首轮筛查MRI进行增量阅片,比较简化方案与完整多参数方案的诊断准确性。简化方案敏感度84.3%与完整方案85.9%无显著差异(P=.68),特异度73.9%与75.8%亦无显著差异(P=.39),阅片时间缩短近50%。

要点

  • 简化乳腺MRI在极密乳腺筛查中敏感度与完整多参数方案相当(84.3% vs 85.9%,P=.68)。
  • 简化方案特异度73.9%与完整方案75.8%无显著差异(P=.39)。
  • 简化方案阅片时间49.7秒,较完整方案96.4秒缩短近50%(P<.001)。

核心结论

  • 在DENSE试验中,极密乳腺且钼靶阴性女性的首轮筛查,简化乳腺MRI诊断准确性高,与完整多参数方案相当,且阅片和扫描时间显著缩短。

研究设计与样本

  • DENSE试验二次分析,纳入518例极密乳腺且钼靶阴性女性的首轮筛查MRI共518次检查,7名放射科医师对同一批MRI按4个增量步骤阅片并给出BI-RADS评分。

关键影像表现/征象

  • 第一步纳入注射对比剂后120秒内的高时间低空间和低时间高空间动态T1加权序列。
  • 最终步骤加入完整方案的所有序列。

诊断标准与关键数值

  • 简化方案敏感度84.3%(95%CI:77.7,89.2)vs 完整多参数方案85.9%(95%CI:80.0,90.3),P=.68。
  • 简化方案特异度73.9%(95%CI:70.7,76.9)vs 完整方案75.8%(95%CI:72.8,78.5),P=.39。
  • 简化方案汇总阅片时间49.7秒(95%CI:48.5,50.9)vs 完整方案96.4秒(95%CI:94.3,98.5),P<.001,缩短近50%。
  • 扫描时间缩短70%-80%,取决于医院和扫描仪厂商。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Abbreviated MRI may reduce costs and time of supplemental breast cancer screening. The Dense Tissue and Early Breast Neoplasm Screening (DENSE) trial provides an opportunity to study this protocol in a true screening population. Purpose To compare multireader diagnostic accuracy of various abbreviated screening breast MRI protocols with that of the full multiparametric protocol in the DENSE trial, focusing on identifying the minimal protocol necessary to maintain high diagnostic accuracy. Materials and Methods In this secondary analysis of a subset from the DENSE trial, seven radiologists performed incremental readings of first-round screening MRI scans in women with extremely dense breasts and findings negative for cancer at mammography. Different sequences were added in four incremental steps. The first step included both high-temporal low-spatial and low-temporal high-spatial dynamic T1-weighted series, up to 120 seconds after contrast agent injection. The final step added all full-protocol sequences. Each radiologist assessed the same MRI scans and provided Breast Imaging Reporting and Data System scores for all four incremental steps. Pooled sensitivity and specificity were calculated across all readers per step using a generalized estimating equation model, and pooled reading time per step was calculated using a linear mixed model. Results The first-round screening included 518 MRI scans from 518 women (median age, 53 years; IQR, 51-59 years), including 83 breast cancers: 68 invasive cancers (82%) and 15 ductal carcinomas in situ (18%). There was no evidence of a difference in sensitivity between abbreviated protocol (84.3%; 95% CI: 77.7, 89.2) and the full multiparametric MRI protocol (85.9%; 95% CI: 80.0, 90.3; P = .68). There was also no evidence of a difference in specificity between abbreviated protocol (73.9%; 95% CI: 70.7, 76.9) and full protocol (75.8%; 95% CI: 72.8, 78.5; P = .39). The abbreviated protocol had a pooled reading time (49.7 seconds; 95% CI: 48.5, 50.9) that was almost 50% shorter than the full protocol (96.4 seconds; 95% CI: 94.3, 98.5; P < .001) with 70%-80% shorter scanning time, depending on hospital and scanner vendor. Conclusion In women in the DENSE trial with extremely dense breasts and findings that were negative for cancer at mammography, abbreviated breast MRI for first-round screening had high diagnostic accuracy that was comparable to full multiparametric protocol, at much shorter reading and scanning times. ClinicalTrials.gov Identifier: NCT01315015 © RSNA, 2025 Supplemental material is available for this article. See also the editorial by Kataoka and Honda in this issue.