文献速递妇产影像技术与安全US

基于定量超声的大鼠先兆子痫模型胎盘组织微结构特征研究

Quantitative Ultrasound-Based Characterization of Placental Tissue Microstructure in a Rat Model of Preeclampsia.
PubMed 文献 · Ultrasound Med Biol · 2025-05-20

研究采用9只定时妊娠Sprague-Dawley大鼠,在妊娠第14天对5只行RUPP手术诱导先兆子痫,妊娠第18天采集超声射频数据进行QUS分析。结果显示活体QUS测得的有效散射体直径与显微镜下细胞核直径测量相关良好(R2=0.58,p=3.8e-6),RUPP胎盘结合带显著小于对照组(p=0.013),平均ESD较对照组小1.0 µm(p=0.040)。结论提示QUS有潜力作为无创工具检测胎盘微结构关键变化。

要点

  • 活体QUS测得的有效散射体直径(ESD)与显微镜下细胞核直径测量相关良好(R2=0.58,p=3.8e-6)。
  • RUPP胎盘结合带显著小于对照胎盘(p=0.013),平均ESD较对照小1.0 µm(p=0.040)。
  • 结合带细胞核直径大于迷路带(p=3.3e-21)和绒毛膜板(p=9.5e-27),其ESD亦大于两者(p=5.6e-4和p=4.5e-8)。

核心结论

  • QUS测得的ESD与胎盘细胞核直径测量相关良好,RUPP胎盘平均ESD较对照小1.0 µm(p=0.040),与结合带缩小一致,提示QUS有潜力无创检测先兆子痫胎盘微结构关键变化。

研究设计与样本

  • 研究使用9只定时妊娠Sprague-Dawley大鼠,妊娠第14天对5只行RUPP手术诱导先兆子痫,妊娠第18天采集超声射频数据进行QUS分析,妊娠第19天处死动物获取胎盘组织样本测量各解剖层细胞核直径并与区域ESD值比较。

关键影像表现/征象

  • RUPP胎盘结合带显著小于对照胎盘(p=0.013)。
  • RUPP胎盘平均ESD较对照胎盘小1.0 µm(p=0.040)。
  • 结合带细胞核直径大于迷路带(p=3.3e-21)和绒毛膜板(p=9.5e-27)。
  • 结合带ESD大于迷路带(p=5.6e-4)和绒毛膜板(p=4.5e-8)。

诊断标准与关键数值

  • 活体QUS测得的ESD与显微镜图像细胞核直径测量相关良好(R2=0.58,p=3.8e-6)。
  • RUPP胎盘平均ESD较对照胎盘小1.0 µm(p=0.040)。
  • RUPP胎盘结合带显著小于对照胎盘(p=0.013)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Quantitative ultrasound (QUS) methods were applied to detect changes in placental microstructure in the reduced uterine perfusion pressure (RUPP) model of preeclampsia in rats. Preeclampsia is a life-threatening pregnancy disorder associated with abnormal placental development that is inadequately treated and managed.

METHODS: Nine timed-pregnant Sprague-Dawley rats were used in this study. On gestational day 14 (GD 14), five rats received RUPP surgery to induce preeclampsia. US radiofrequency data were acquired for QUS analysis on GD18. On GD19, animals were sacrificed and dissected to acquire placental tissue samples. The cell nuclear diameter in each anatomical layer of the placenta was measured to compare with regional effective scatterer diameter (ESD) values.

RESULTS: ESD measurements obtained using in vivo QUS imaging correlated well (R2 = 0.58, p = 3.8e-6) with cell nucleus diameter measurements from microscopy images. RUPP placentas had significantly smaller junctional zones compared to control placentas (p = 0.013). The average ESD in RUPP placentas was 1.0 µm smaller compared to control placentas (p = 0.040). This decrease in ESD in RUPP placentas is consistent with the decreased size of the junctional zone, which, in comparison to the labyrinth zone and chorionic plate, has larger cell nuclei (p = 3.3e-21 and p = 9.5e-27, respectively) and larger ESD (p = 5.6e-4 and p = 4.5e-8, respectively).

CONCLUSION: These results demonstrate the potential of QUS as a non-invasive tool for detecting critical changes in placental microstructure, improving maternal and fetal outcomes by enabling earlier diagnosis and more timely therapeutic interventions in preeclampsia.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Markel AC, Hoerig C, de Alencar AKN, et al. Quantitative Ultrasound-Based Characterization of Placental Tissue Microstructure in a Rat Model of Preeclampsia. Ultrasound Med Biol. 2025. PMID: 40399229. doi:10.1016/j.ultrasmedbio.2025.04.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。