基于前列腺影像质量(PI-QUAL)第2版评估双参数MRI的诊断效能:多机构数据分析
回顾性纳入112例在69家外院机构行双参数MRI并转诊至三级中心的前列腺癌疑似患者,用PI-QUAL v2评分评估图像质量;47例(42.0%)不适用于PI-QUAL v2评分,余下病例中PI-QUAL v2评分1分者检出临床显著前列腺癌的敏感度74.3%,显著低于2分或3分者的100.0%(P=0.045);T2WI平面内分辨率和DWI b值数量与图像质量评估显著相关(P=0.037和0.028)。
要点
- PI-QUAL v2评分≤1分的双参数MRI检出临床显著前列腺癌敏感度74.3%,低于2分或3分的100.0%(P=0.045)。
- T2WI平面内分辨率与图像质量评估显著相关(P=0.037)。
- DWI b值数量与图像质量评估显著相关(P=0.028)。
核心结论
- 双参数MRI检出临床显著前列腺癌的诊断准确率受图像质量影响,图像质量以PI-QUAL v2评分系统评估。
研究设计与样本
- 回顾性研究,纳入2020年1月至2021年11月在69家外院影像机构行双参数MRI并转诊至作者三级中心的112例男性患者,由两名放射科医生共识采用PI-QUAL v2评估图像质量,并提取T2WI和DWI技术参数。
诊断标准与关键数值
- 112例中47例(42.0%)MRI不适用于PI-QUAL v2评分;余下病例中PI-QUAL v2评分1分30例(26.8%)、2分17例(15.2%)、3分18例(16.1%)。
局限性
- 112例中47例(42.0%)MRI不适用于PI-QUAL v2评分。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the impact of image quality on the diagnostic performance of biparametric MRI (bpMRI) for detecting clinically significant prostate cancer (csPCa).
PATIENTS AND METHODS: This retrospective study included patients who underwent bpMRI at outside imaging facilities and were referred to our tertiary centre between January 2020 and November 2021. The image quality of bpMRI was assessed by two radiologists in consensus using Prostate Imaging Quality Score version 2 (PI-QUAL v2). Technical parameters of T2WI and DWI were extracted, and their associations with imaging quality criteria were evaluated. Sensitivity, specificity, and positive and negative predictive values for detecting csPCa were compared according to PI-QUAL v2 scores.
RESULTS: Among 112 men who underwent bpMRI at 69 different imaging facilities, 47 (42.0 %) MRIs were considered not applicable for PI-QUAL v2 scoring. Of the remaining MRIs, 30 (26.8 %), 17 (15.2 %), and and 18 (16.1 %) were assigned PI-QUAL v2 scores of 1, 2, and 3, respectively. MRIs with PI-QUAL v2 scores ≤ 1 demonstrated significantly lower sensitivity (74.3 %) than those with scores of 2 or 3 (100.0 %; P = 0.045). In-plane resolution on T2WI and the number of b values on DWI were significantly associated with image quality assessment (P = 0.037 and 0.028).
CONCLUSIONS: The diagnostic accuracy of bpMRI for detecting csPCa is influenced by image quality, as assessed by the PI-QUAL v2 scoring system. Adequate in-plane resolution on T2WI and the use of at least three b values on DWI should be emphasised to achieve optimal image quality and diagnostic performance.
引用
- Shin JI, Park KJ, Park MY, et al. Diagnostic performance of biparametric MRI according to prostate imaging quality (PI-QUAL) version 2: Analysis of Multi-Institutional Data. Eur J Radiol. 2025. PMID: 40446571. doi:10.1016/j.ejrad.2025.112209
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。