文献速递泌尿生殖腹部MR

基于深度学习的解剖感知形态模型用于前列腺全标本组织病理与MRI配准

Deep Learning-based Anatomy-Aware Morph Model for Registration of Prostate Whole-Mount Histopathology to MRI.
PubMed 文献 · Radiol Imaging Cancer · 2025-01-01

本研究为回顾性研究,开发并评估一种基于深度学习的解剖感知形态模型,用于术前前列腺MRI与全标本组织病理(WMHP)图像配准。在45例测试集患者中,配准后DSC达0.95±0.06,Hausdorff距离1.84 mm±0.38,二维目标配准误差在配准后从3.93 mm±0.80降至1.18 mm±0.28(P<.001),并显著优于VoxelMorph方法(DSC与Hausdorff距离均P<.0001)。

要点

  • 配准后DSC为0.95±0.06,Hausdorff距离为1.84 mm±0.38。
  • 二维目标配准误差配准前3.93 mm±0.80 vs 配准后1.18 mm±0.28(P<.001)。
  • 该算法在DSC和Hausdorff距离上均显著优于VoxelMorph(均P<.0001)。

核心结论

  • 所开发的配准方法成功对齐了术前前列腺MR与组织病理图像,有助于将前列腺癌从WMHP自动映射到MRI。

研究设计与样本

  • 回顾性研究,纳入2016年7月至2020年6月间根治性前列腺切除术前接受前列腺MRI的患者,数据集分为270例训练和45例测试;以高分辨率离体MRI为参考评估体内MRI与WMHP的结构关系。

诊断标准与关键数值

  • 测试集45例男性患者(平均年龄64.0岁±6.6)提取的160幅图像验证:DSC 0.95±0.06,Hausdorff距离1.84 mm±0.38。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To develop and evaluate a novel deep learning-based approach for registering presurgical MR and whole-mount histopathology (WMHP) images of the prostate. Materials and Methods This retrospective study included patients who underwent prostate MRI before radical prostatectomy between July 2016 and June 2020. High-resolution ex vivo MRI was used as a reference to assess the structural relationship between in vivo MRI and WMHP. An Anatomy-Aware Morph model, a hybrid attention and convolutional neural network-based approach, was developed for multimodality prostate image registration. The pipeline included a module to estimate and correct distortion and motion between the prostate specimen and outside the human body. The dataset was divided into 270 and 45 patients for training and testing, respectively. Registration accuracy was evaluated using Dice similarity coefficient (DSC), Hausdorff distance, and target registration error. Results The proposed approach was validated using 160 images extracted from 45 male patients in the testing dataset with the average age ± SD of 64.0 years ± 6.6. The method achieved a DSC and Hausdorff distance of 0.95 ± 0.06 and 1.84 mm ± 0.38. The two-dimensional target registration errors between 90 sets of landmarks on in vivo MR images and WMHP images were 3.93 mm ± 0.80 and 1.18 mm ± 0.28 before and after registration (P < .001). The developed algorithm significantly outperformed the state-of-the-art VoxelMorph method for multimodality prostate image registration (P < .0001 for both DSC and Hausdorff distance). Conclusion The developed registration method successfully aligned presurgical prostate MR and histopathology images, facilitating automated mapping of prostate cancer from WMHP to MRI. Keywords: Affine Transformation, Deformable Registration, Prostate Magnetic Resonance Imaging, Prostate Whole-Mount Histopathology Supplemental material is available for this article. © RSNA, 2025.

来源:Radiol Imaging Cancer,查看原文。版权归原作者所有。

引用

  1. Zabihollahy F, Wu HH, Sisk AE, et al. Deep Learning-based Anatomy-Aware Morph Model for Registration of Prostate Whole-Mount Histopathology to MRI. Radiol Imaging Cancer. 2025. PMID: 40445100. doi:10.1148/rycan.240336