回顾性单中心研究纳入57例切除的肠型壶腹部癌(ITAC)与非壶腹部十二指肠癌(NADC)患者,术前行定制十二指肠对比增强MDCT,三名放射科医生独立用四项影像标准鉴别两种癌。病灶形状和十二指肠胰腺沟固定特异度高、观察者间一致性中等/强,四项标准综合鉴别ITAC与NADC的敏感度和特异度分别为85.7%和83.3%。

要点

  • 病灶形状和十二指肠胰腺沟固定鉴别ITAC与NADC特异度高(最高92%和93%),观察者间一致性中等/强(κ=0.72和0.81)。
  • 四项影像标准综合鉴别ITAC与NADC的敏感度85.7%、特异度83.3%。
  • 导管截断和胰十二指肠动脉浸润的观察者间一致性较低(κ=0.52和0.44)。

核心结论

  • 定制十二指肠MDCT上,病灶形状和十二指肠胰腺沟固定对术前鉴别ITAC与NADC具有高特异度和中等/强观察者间一致性;四项标准综合鉴别ITAC与NADC的敏感度85.7%、特异度83.3%。

研究设计与样本

  • 回顾性单中心研究,纳入57例(平均年龄55岁±18.2,25名女性)切除的ITAC和NADC患者,术前均行定制十二指肠对比增强MDCT;三名放射科医生独立阅片,以组织病理学为参考标准。

关键影像表现/征象

  • ITAC与NADC在病灶形状(p<0.0001)和十二指肠胰腺沟固定(p<0.0007)上差异有统计学意义。
  • 病灶形状鉴别ITAC的敏感度47-66%、特异度83-92%(κ=0.72)。
  • 十二指肠胰腺沟固定鉴别ITAC的敏感度54-73%、特异度86-93%(κ=0.81)。
  • 导管截断鉴别ITAC的敏感度24-52%、特异度61-71%(κ=0.52)。
  • 胰十二指肠动脉浸润鉴别ITAC的敏感度19-28%、特异度48-52%(κ=0.44)。

诊断标准与关键数值

  • 四项影像标准包括:病灶形状、导管截断、十二指肠胰腺沟固定和胰十二指肠动脉浸润。
  • 病灶形状鉴别ITAC的敏感度47-66%、特异度83-92%(κ=0.72)。
  • 十二指肠胰腺沟固定鉴别ITAC的敏感度54-73%、特异度86-93%(κ=0.81)。
  • 导管截断鉴别ITAC的敏感度24-52%、特异度61-71%(κ=0.52)。
  • 胰十二指肠动脉浸润鉴别ITAC的敏感度19-28%、特异度48-52%(κ=0.44);四项标准综合鉴别ITAC与NADC的敏感度85.7%、特异度83.3%。

临床应用与阅片要点

  • 定制十二指肠MDCT上,病灶形状和十二指肠胰腺沟固定特异度高、观察者间一致性中等/强,可用于术前鉴别ITAC与NADC。
  • 病灶形状和十二指肠胰腺沟固定对鉴别ITAC与NADC的观察者间一致性分别为κ=0.72和κ=0.81。
  • 导管截断和胰十二指肠动脉浸润的观察者间一致性较低(κ=0.52和κ=0.44)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic accuracy of four imaging criteria obtained with a tailored duodenal MDCT to differentiate non-ampullary duodenal carcinoma (NADC) and intestinal-type ampullary carcinoma (ITAC).

MATERIALS AND METHODS: In this retrospective single-center study, patients with resected ITAC and NADC who underwent preoperative contrast-enhanced MDCT using a tailored duodenal protocol were included. Three radiologists independently reviewed each MDCT, using four imaging criteria to differentiate the two cancer types: lesion shape, ductal cutoff, duodenopancreatic groove fixation and pancreatico-duodenal artery infiltration. Sensitivity, specificity, positive and negative predictive values of the imaging criteria were calculated using histopathologic analysis as the reference standard. Interobserver agreements were assessed using kappa statistics.

RESULTS: 57 patients (mean age 55 years ± 18.2 (standard deviation); 25 women) were included in the study. ITAC was significantly different in terms of lesion shape (p < 0.0001) and duodenopancreatic groove fixation (p < 0.0007). Sensitivity and specificity of the lesion shape for the three readers were 47-66%, 83-92% (κ = 0.72); of the ductal cutoff were 24-52%, 61-71% (κ = 0.52); of the duodenopancreatic groove fixation were 54-73%, 86-93% (κ = 0.81); of the pancreatico-duodenal artery infiltration were 19-28%, 48-52% (κ = 0.44). When all features were taken into account, sensitivity and specificity in differentiating between ITAC vs NADC were 85.7% and 83.3%.

CONCLUSION: The lesion shape and duodenopancreatic groove fixation have high specificity and moderate/strong interreader agreement for preoperative differentiation of ITAC and NADC on tailored duodenal MDCT.

KEY POINTS: Question Preoperative differentiation of non-ampullary duodenal carcinoma and intestinal-type ampullary carcinoma has potential implications on patients' management. Findings Two imaging criteria acquired on a tailored duodenal CT allowed to differentiate between intestinal-type ampullary carcinoma non-ampullary duodenal carcinoma with > 80% sensitivity and specificity. Clinical relevance A tailored duodenal CT is a reliable tool to differentiate between intestinal-type ampullary carcinoma and non-ampullary duodenal carcinoma, with potential treatment implications.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ivanovic AM, Gore RM, Saxena S, et al. Differentiation of non-ampullary duodenal carcinoma from intestinal-type ampullary carcinoma by tailored multidetector CT: utility of four imaging criteria. Eur Radiol. 2025. PMID: 40366388. doi:10.1007/s00330-025-11677-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。