精准CT血管造影(CTA)扫描技术在下肢动脉疾病评估中的应用与意义
本研究将89例疑似下肢动脉疾病患者随机分为精准组(A组,采用可变螺旋螺距VHP)与传统组(B组,标准螺距),比较图像质量、对比剂剂量和辐射剂量。A组下肢动脉图像质量主观与客观评价均更优,踝部及足背图像尤为明显(均P<0.001),主观评分较B组高21%(P<0.05);A组辐射剂量降低16.23%、对比剂剂量降低12.28%(均P<0.001)。结论认为VHP可改善远端血管显示、提高图像质量并减少辐射与对比剂用量。
要点
- A组采用可变螺旋螺距(VHP),B组采用标准螺距扫描。
- A组踝部及足背图像质量主观评分显著更高(均P<0.001)。
- A组较B组辐射剂量降低16.23%、对比剂剂量降低12.28%(均P<0.001)。
核心结论
- 采用VHP的CTA扫描可增强远端血管显示、提高图像质量,并减少辐射暴露和对比剂用量。
研究设计与样本
- 研究纳入89例疑似下肢动脉疾病患者,随机分为精准扫描组(A组,可变螺旋螺距VHP)与传统扫描组(B组,标准螺距)。
- 在腰椎4水平(腹主动脉)、髂动脉水平、腘动脉水平、踝关节水平及足背水平五个解剖位置评估CT值和图像噪声,并计算各节段信噪比(SNR)和对比噪声比(CNR)。
- 由两名放射科医师进行主观评价评分。
关键影像表现/征象
- A组下肢动脉图像质量的主观(SNR、CNR、CT值)与客观评价(两名放射科医师评分)均优于B组。
- A组下肢CTA主观指标显著更高,尤其在踝部及足背图像(均P<0.001)。
诊断标准与关键数值
- A组主观评分较B组高21%(P<0.05)。
- A组辐射剂量较B组降低16.23%(P<0.001)。
- A组对比剂剂量较B组降低12.28%(P<0.001)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIMS: This study compares image quality, contrast agent dosage, and radiation exposure between an advanced precision scanning technique and traditional computed tomography angiography (CTA) scanning methods of the lower limb.
MATERIALS AND METHODS: A cohort of 89 patients with suspected lower limb arterial disease was randomly assigned to precise (A) and traditional (B) CTA scanning. group A used variable helical pitch (VHP), while group B used a standard pitch scanning technique. Computed tomography values and image noise were assessed at five anatomical locations, including the lumbar 4 level (abdominal aorta), iliac artery level, popliteal artery level, ankle joint level, and dorsal foot level in both groups. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were computed for each segment, followed by statistical analysis.
RESULTS: Both subjective (SNR, CNR, and CT values) and objective evaluations (evaluation scores of two radiologists) demonstrated superior image quality of lower extremity arteries in group A. The subjective metric was significantly higher in lower limb CTA, particularly at the ankle and dorsum of foot images (all P<0.001), and the subjective score for group A was 21% higher than that of group B (P<0.05). In terms of patients' radiation dose and contrast agent dosage, group A exhibited a 16.23% reduction in radiation dose and a 12.28% reduction in contrast agent dosage compared to group B, respectively (both P<0.001).
CONCLUSION: The use of VHP in CTA scanning enhances distal blood vessel visualisation, improves image quality, and reduces radiation exposure and contrast agent consumption, offering substantial clinical benefits.
引用
- Xing J, Shi J, Tong L, et al. Application and significance of precise computed tomography angiography (CTA) scanning technology in the assessment of lower extremity arterial diseases. Clin Radiol. 2025. PMID: 40403343. doi:10.1016/j.crad.2025.106933
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。