灌注CT与常规薄层多期CT诊断胰腺腺癌的比较
回顾性纳入2021年12月至2024年4月60例患者,序贯行灌注CT与常规CT,比较平均时间(MT)后处理灌注CT与常规薄层多期CT在显示肿瘤、胰腺小动脉及评估可切除性方面的一致性。MT图像肿瘤显示评分、对比度、信噪比与对比噪声比均优于常规CT,胰腺小动脉定性评分更高,两种检查可切除性一致性良好,有效辐射剂量无显著差异。
要点
- MT后处理灌注CT较常规薄层多期CT肿瘤显示更清晰,肿瘤对比度、信噪比及对比噪声比均更高(均P<0.001)。
- MT图像对胰腺小动脉的定性评分更高,多数P值<0.05(范围<0.001至0.018)。
- 两种检查评估肿瘤可切除性一致性良好(两名放射科医师κ值分别为0.740和0.785)。
核心结论
- 采用MT后处理的灌注CT在显示肿瘤和胰腺小动脉方面优于常规CT,两种检查的可切除性评估结果一致。
研究设计与样本
- 回顾性研究,纳入60例患者(平均年龄61.3±8.8岁,男性36例),于2021年12月至2024年4月序贯行灌注CT与常规CT检查,比较MT后处理图像与常规图像。
关键影像表现/征象
- MT图像肿瘤显示定性5分评分高于常规CT:5(4,5)vs 4(4,5)。
- MT图像肿瘤对比度高于常规CT:99.54(81.88, 117.29)vs 51.90±18.85。
- MT图像信噪比高于常规CT:4.46±1.75 vs 3.10±0.98。
- MT图像对比噪声比高于常规CT:5.13(3.84, 6.77)vs 3.03±1.24,以上P值均<0.001。
- MT图像胰腺小动脉定性4分评分更高,多数P值<0.05(范围<0.001至0.018)。
诊断标准与关键数值
- 肿瘤显示采用定性5分评分,MT图像评分5(4,5)vs 常规CT 4(4,5)。
- 胰腺小动脉显示采用定性4分评分,MT图像评分更高,多数P值<0.05(范围<0.001至0.018)。
- 两名放射科医师评估可切除性一致性κ值分别为0.740和0.785。
- 灌注CT有效辐射剂量11.86(9.45, 15.57)mSv vs 常规CT 12.47±4.01 mSv,P=0.958。
临床应用与阅片要点
- MT后处理灌注CT图像可改善胰腺腺癌肿瘤的显示及与周围组织的对比。
- MT图像对小胰腺动脉的显示评分高于常规薄层多期CT。
- 灌注CT与常规CT评估肿瘤可切除性结果一致(κ=0.740和0.785)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Perfusion CT parameters are reported to correlate with pancreatic adenocarcinoma's histopathological response to radiochemotherapy, yet research on morphological diagnosis of perfusion CT for the diagnosis of pancreatic adenocarcinoma is lacking. This study compares mean temporal (MT) post-processed perfusion CT with conventional thin-slice multiphase CT in visualizing tumors, small pancreatic arteries, and assessing tumor resectability.
MATERIALS AND METHODS: 60 patients (mean age 61.3 ± 8.8, 36 males) underwent perfusion and conventional CT sequentially from December 2021 to April 2024 were retrospectively included. MT images were calculated from perfusion CT and compared with conventional images for tumor depiction (qualitative 5-point scale, quantitative analysis), small pancreatic arteries display (qualitative 4-point scale) and concordance in tumor resectability. Radiation doses were also evaluated.
RESULTS: MT images showed superior tumor display scores (5 (4,5) vs. 4 (4,5)), better tumor contrast (99.54 (81.88, 117.29) vs. 51.90 ± 18.85), higher signal-to-noise ratio (4.46 ± 1.75 vs. 3.10 ± 0.98), and contrast-to-noise ratio (5.13 (3.84, 6.77) vs. 3.03 ± 1.24), with all p values < 0.001. Qualitative scores for small pancreatic arteries were higher in MT images, with most p values <0.05 (range from <0.001 to 0.018). Both radiologists showed good resectability consistency, with κ values of 0.740 and 0.785, respectively. Effective radiation doses were 11.86 (9.45, 15.57) mSv for perfusion CT and 12.47 ± 4.01 mSv for conventional CT (p=0.958).
CONCLUSION: Perfusion CT employing MT post-processing outperforms conventional CT in depicting tumors and small pancreatic arteries, with consistent resectability results between the two examinations.
引用
- Li J, Chen XY, Wang YH, et al. Comparison of Perfusion CT and Conventional Thin-slice Multiphase CT in the Diagnosis of Pancreatic Adenocarcinoma. Acad Radiol. 2025. PMID: 40393830. doi:10.1016/j.acra.2025.03.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。